Nordic Geothermal Heat Pumps — ENERGY STAR Certified Models
Rated from 4.1 COP to 4.6 COP over 52 certified combinations, Nordic's 32 residential geothermal heat pumps models use Other, R-410A. Nordic Geothermal Heat Pumps — ENERGY STAR Certified Models benchmarks residential systems using Certified Models set at 32 and Rating Span set at 4.1 COP - 4.6 COP. Values trace to primary federal, state, or OEM filings supporting Nordic Geothermal Heat Pumps — ENERGY STAR Certified Models across single-family housing.
- Certified Models
- 32
- Rating Span
- 4.1 COP - 4.6 COP
- Capacity Range
- Residential capacities
- AHRI Combinations
- 52
- Cold Climate Units
- 0
- Category Median
- 4.5 COP
How does Nordic's geothermal heat pumps portfolio cover capacity, refrigerants, and safety?
Nordic covers Residential capacities in geothermal heat pumps across 32 canonical models and 52 AHRI combinations, with 0 Cold Climate certified models and Other, R-410A. Ratings span 4.1 COP up to 4.6 COP (category median 4.5 COP, certified through 2023-09-12). CPSC records show 0 residential HVAC recall notices matching Nordic; check exact AHRI matched pairings on individual model sheets.
Which verified records belong in Nordic Geothermal Heat Pumps — ENERGY STAR Certified Models?
Compare all 32 verified entries below. Click any column header to sort numerically or alphabetically, then select any row for full benchmark citations.
| Nordic R55HACW-P-1T-*-SDE** | 4.6 COP | 25.5 EER | Open Loop Water-to-Air | 2 |
| Nordic R65HACW-P-1T-*-SDE** | 4.6 COP | 24.3 EER | Open Loop Water-to-Air | 2 |
| Nordic RS55HACW-P-1T-* | 4.6 COP | 25.5 EER | Open Loop Water-to-Air | 2 |
| Nordic RS65HACW-P-1T-* | 4.6 COP | 24.3 EER | Open Loop Water-to-Air | 2 |
| Nordic TF55HACW-P-1T-*-SDE** | 4.6 COP | 24.8 EER | Open Loop Water-to-Air | 2 |
| Nordic R-55-HACW-X-1T-*-*DE**-** | 4.5 COP | 25.1 EER | Open Loop Water-to-Air | 2 |
| Nordic R-65-HACW-X-1T-*-*DE**-** | 4.5 COP | 24.1 EER | Open Loop Water-to-Air | 2 |
| Nordic R-75-HACW-X-1T-*-*DE**-** | 4.5 COP | 23.5 EER | Open Loop Water-to-Air | 2 |
| Nordic RS-55-HACW-X-1T-*-** | 4.5 COP | 25.1 EER | Open Loop Water-to-Air | 2 |
| Nordic RS-65-HACW-X-1T-*-** | 4.5 COP | 24.1 EER | Open Loop Water-to-Air | 2 |
| Nordic RS-75-HACW-X-1T-*-** | 4.5 COP | 23.5 EER | Open Loop Water-to-Air | 2 |
| Nordic TF-55-HSCW-X-1T-**-*DE**-** | 4.5 COP | 24.6 EER | Open Loop Water-to-Air | 2 |
| Nordic R-45-HACW-X-1T-*-*DE**-** | 4.4 COP | 24.8 EER | Open Loop Water-to-Air | 2 |
| Nordic R45HACW-P-1T-*-SDE** | 4.4 COP | 24.3 EER | Open Loop Water-to-Air | 2 |
| Nordic RH-45-HACW-X-1T-*-*DE**-** | 4.4 COP | 24.8 EER | Open Loop Water-to-Air | 2 |
| Nordic RS-45-HACW-X-1T-*-** | 4.4 COP | 24.8 EER | Open Loop Water-to-Air | 2 |
| Nordic RS45HACW-P-1T-* | 4.4 COP | 24.3 EER | Open Loop Water-to-Air | 2 |
| Nordic TF-45-HSCW-X-1T-**-*DE**-** | 4.4 COP | 24.8 EER | Open Loop Water-to-Air | 2 |
| Nordic TF45HACW-P-1T-*-SDE** | 4.4 COP | 24.0 EER | Open Loop Water-to-Air | 2 |
| Nordic RH45HACW-P-1T-*-SDE** | 4.3 COP | 22.8 EER | Open Loop Water-to-Air | 2 |
| Nordic RH-55-HACW-X-1T-*-*DE**-** | 4.5 COP | 23.4 EER | Open Loop Water-to-Air | 1 |
| Nordic RH55HACW-P-1T-*-SDE** | 4.5 COP | 23.0 EER | Open Loop Water-to-Air | 1 |
| Nordic TF-65-HSCW-X-1T-**-*DE**-** | 4.5 COP | 24.1 EER | Open Loop Water-to-Air | 1 |
| Nordic TF65HACW-P-1T-*-SDE** | 4.5 COP | 23.9 EER | Open Loop Water-to-Air | 1 |
| Nordic RH-65-HACW-X-1T-*-*DE**-** | 4.4 COP | 23.0 EER | Open Loop Water-to-Air | 1 |
| Nordic RH65HACW-P-1T-*-SDE** | 4.4 COP | 22.6 EER | Open Loop Water-to-Air | 1 |
| Nordic TF-75-HSCW-X-1T-**-*DE**-** | 4.4 COP | 23.5 EER | Open Loop Water-to-Air | 1 |
| Nordic R75HACW-P-1T-*-SDE** | 4.3 COP | 21.2 EER | Open Loop Water-to-Air | 1 |
| Nordic RH-75-HACW-X-1T-*-*DE**-** | 4.3 COP | 21.3 EER | Open Loop Water-to-Air | 1 |
| Nordic RS75HACW-P-1T-* | 4.3 COP | 21.2 EER | Open Loop Water-to-Air | 1 |
| Nordic TF75HACW-P-1T-*-SDE** | 4.2 COP | 21.2 EER | Open Loop Water-to-Air | 1 |
| Nordic RH75HACW-P-1T-*-SDE** | 4.1 COP | 21.2 EER | Open Loop Water-to-Air | 1 |
Which top Nordic geothermal heat pumps anchor this lineup?
Select any of the 4 verified listings below to open detailed specifications, safety boundaries, and source links.
Nordic R55HACW-P-1T-*-SDE**
Nordic R65HACW-P-1T-*-SDE**
Nordic RS55HACW-P-1T-*
Nordic RS65HACW-P-1T-*
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Nordic Geothermal Heat Pumps, review 3 important real-world limits and verify local licensing and permit rules directly.
- Cohort spread across Nordic: 4.1 COP entry units differ substantially from flagship R55HACW-P-1T-*-SDE** (4.6 COP).
- Verify indoor coil AHRI pairing on PD ID 2667731 and 2636136 before pulling state mechanical permits.
- Equipment catalog metrics exclude ductwork upgrades, A2L leak sensors where applicable, and municipal inspection fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Best fit for Nordic | Homes matched to Residential capacities seeking Other, R-410A compliance and verified ENERGY STAR documentation. |
| Skip or verify further if | Existing ductwork pushes total static pressure above 0.50 in. w.c. or 3-phase commercial wiring is present. |
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
Which Nordic geothermal heat pumps model reaches the highest 4.6 COP rating?
R55HACW-P-1T-*-SDE** tops Nordic's 32 ENERGY STAR geothermal heat pumps models at 4.6 COP across 2 AHRI matches (PD ID 2667731).
How broad is Nordic's geothermal heat pumps efficiency and BTU range?
Nordic spans 4.1 COP (RH75HACW-P-1T-*-SDE**) up to 4.6 COP (R55HACW-P-1T-*-SDE**) across Residential capacities, compared with the 4.5 COP category median.
How many AHRI combinations support Nordic geothermal heat pumps?
Current ENERGY STAR datasets document 52 verified indoor-outdoor AHRI combinations distributed across 32 canonical Nordic models.
What refrigerants or fuels power Nordic geothermal heat pumps?
Nordic geothermal heat pumps listings record Other, R-410A, with 0 Cold Climate certified models inside the geothermal heat pumps cohort.
Where are Nordic geothermal heat pumps compliant under 2026 federal rules?
Models meeting 13.4 SEER2 qualify in the North; 14.3 SEER2 (plus 11.7 EER2 or 9.8 at 15.2+ SEER2) is needed for Southwest split cooling, while split heat pumps require 14.3 SEER2 / 7.5 HSPF2 nationwide.
Are any CPSC safety recalls linked to Nordic residential HVAC products?
ThermalSpec counts 0 residential HVAC CPSC filings referencing Nordic; verify model serial prefixes at /recalls/ before installation or service.
Do Nordic geothermal heat pumps receive federal Section 25C credits in 2026?
No — IRS Section 25C credits terminated December 31, 2025 ($0 federal tax credit for Nordic in 2026). Check state HOMES/HEAR and local utility ENERGY STAR rebates using PD ID 2667731.
How should homeowners select among Nordic's 32 geothermal heat pumps models?
Match Nordic model capacity (Residential capacities) using an ACCA Manual J room-by-room heat load and <= 0.50 in. w.c. static pressure check rather than old unit tonnage.
Sources
Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)
Related Pages