GeoSmart Energy S7A(V/H)036BV1**2 — Geothermal Heat Pump Specifications
GeoSmart Energy S7A(V/H)036BV1**2 (Geothermal Heat Pump, PD ID 3555597) holds 2 ENERGY STAR certified SKUs rated at 5.3 COP — #36 of 1,730 (Top 2.9%, 15 tied), +0.80 COP. ENERGY STAR certified residential HVAC model. GeoSmart Energy S7A(V/H)036BV1**2 — Geothermal Heat Pump Specifications benchmarks residential systems using Heating COP set at 5.3 COP and Cohort Rank set at #36/1,730.
- Heating COP
- 5.3 COP
- Cohort Rank
- #36/1,730
- Verified Combos
- 2 SKUs
- Sample PD ID
- 3555597
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 3.9 - 4.1 COP | 228 | Peer range |
| 4.1 - 4.3 COP | 329 | Peer range |
| 4.3 - 4.5 COP | 251 | Peer range |
| 4.5 - 4.7 COP | 296 | Peer range |
| 4.7 - 4.9 COP | 244 | Peer range |
| 4.9 - 5.1 COP | 310 | Peer range |
| 5.1 - 5.3 COP | 37 | This series |
| 5.3 - 5.5 COP | 32 | Peer range |
| 5.5 - 5.7 COP | 3 | Peer range |
How does GeoSmart Energy S7A(V/H)036BV1**2 rank across federal compliance and ENERGY STAR cohorts?
GeoSmart Energy S7A(V/H)036BV1**2 ranks #36 of 1,730 (tied with 14 others at 5.30 COP, top 2.9%, more efficient than 97.1% of certified series) for Max COP (+0.80 COP vs 4.50 COP category median) across 2 certified SKU combinations. Open Loop Water-to-Air unit delivering 5.3 COP and 40.2 EER across closed- or open-loop residential piping.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max COP) | #36 of 1,730 (Top 2.9%, 15 tied) | +0.80 COP vs 4.50 COP category median |
| Closed/Open Loop EER vs Cohort | 40.2 EER | +15.60 EER vs 24.6 EER median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| ENERGY STAR Most Efficient Criteria | MOST EFFICIENT | Max COP 5.3 / Max EER 40.2 (Open Loop Water-to-Air) |
| EPA AIM Act Refrigerant Transition | VERIFY OEM SPEC | Dataset refrigerant: Other |
How much annual energy and operating cost does GeoSmart Energy S7A(V/H)036BV1**2 require?
Annual cost outputs combine GeoSmart Energy S7A(V/H)036BV1**2's 5.3 COP rating and EIA national tariffs across single-family runtime hours.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Ground-Source Heating Electricity | 2,765 kWh/yr | $452/yr |
| Ground-Source Cooling Electricity (1,000 hrs) | 896 kWh/yr | $146/yr |
| Total Annual Geothermal Operating Cost | $598/yr | State range: $466 to $1,727 |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to GeoSmart Energy S7A(V/H)036BV1**2?
Showing 2 certified indoor-outdoor coil combinations from 2 total AHRI matched records filed for GeoSmart Energy S7A(V/H)036BV1**2 (PD ID 3555597).
| S7A(V/H)036BV1**2 | Matched AHRI Coil | — | |
| S7A(V/H)036BV1**2 | Matched AHRI Coil | — |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on GeoSmart Energy S7A(V/H)036BV1**2, review 2 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across GeoSmart Energy S7A(V/H)036BV1**2: headline Max COP reflects peak tested matches among 2 SKUs, not lower-rated sizes.
- Catalog specs for GeoSmart Energy S7A(V/H)036BV1**2 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal GeoSmart Energy S7A(V/H)036BV1**2 fit | Single-family replacement needing documented ENERGY STAR PD ID 3555597 with matching indoor air handler. |
| Skip GeoSmart Energy S7A(V/H)036BV1**2 if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable geothermal heat pump models deliver similar efficiency?
Compare GeoSmart Energy S7A(V/H)036BV1**2 against Enertech EVS018* and closely matched geothermal heat pump units sharing similar Max COP output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does GeoSmart Energy S7A(V/H)036BV1**2 compare with peer Geothermal Heat Pump units?
GeoSmart Energy S7A(V/H)036BV1**2 holds #36 of 1,730 (Top 2.9%, 15 tied) out of 1,730 verified geothermal heat pump models (+0.80 COP vs 4.50 COP category median), spanning 2 certified SKUs up to 5.3 COP. Closest same-cohort alternatives include Enertech EVS018*.
Where is GeoSmart Energy S7A(V/H)036BV1**2 compliant for 2026 US installation?
GeoSmart Energy S7A(V/H)036BV1**2: ENERGY STAR certified residential HVAC model. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does GeoSmart Energy S7A(V/H)036BV1**2 model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, GeoSmart Energy S7A(V/H)036BV1**2 runs 2,765 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does GeoSmart Energy S7A(V/H)036BV1**2 cover?
GeoSmart Energy S7A(V/H)036BV1**2 covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does GeoSmart Energy S7A(V/H)036BV1**2 handle extreme weather or cold snaps?
GeoSmart Energy S7A(V/H)036BV1**2 is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.
What refrigerant class and 2026 tax credit rules govern GeoSmart Energy S7A(V/H)036BV1**2?
GeoSmart Energy S7A(V/H)036BV1**2 specifies Other compliance (PD ID 3555597); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 2 certified SKUs in GeoSmart Energy S7A(V/H)036BV1**2 reach 5.3 COP?
Peak 5.3 COP represents the top tested AHRI pairing for GeoSmart Energy S7A(V/H)036BV1**2 (PD ID 3555597); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to GeoSmart Energy S7A(V/H)036BV1**2?
GeoSmart Energy S7A(V/H)036BV1**2 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Enertech EVS018*.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)