Hydron Module HVS018*****1 — Geothermal Heat Pump Specifications

Hydron Module HVS018*****1 (Geothermal Heat Pump, PD ID 2546230) holds 2 ENERGY STAR certified SKUs rated at 5.3 COP — #36 of 1,730 (Top 2.9%, 15 tied), +0.80 COP. ENERGY STAR certified residential HVAC model. Hydron Module HVS018*****1 — Geothermal Heat Pump Specifications benchmarks residential systems using Heating COP set at 5.3 COP and Cohort Rank set at #36/1,730.

Heating COP
5.3 COP
Cohort Rank
#36/1,730
Verified Combos
2 SKUs
Sample PD ID
2546230
Geothermal Heat Pump Efficiency Spread across 1730 certified series (3.9 to 5.7 COP)
Hydron Module HVS018*****1 Geothermal Heat Pump Efficiency Spread Distribution Distribution of 1730 certified series from 3.9 to 5.7 COP. Hydron Module HVS018*****1 sits at 5.3 COP; typical midpoint is 4.5 COP. 228 3.9 329 4.1 251 4.3 296 4.5 244 4.7 310 4.9 37 5.1 32 5.3 3 5.5 Median 4.5 COP This model: 5.3 COP (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
3.9 - 4.1 COP228Peer range
4.1 - 4.3 COP329Peer range
4.3 - 4.5 COP251Peer range
4.5 - 4.7 COP296Peer range
4.7 - 4.9 COP244Peer range
4.9 - 5.1 COP310Peer range
5.1 - 5.3 COP37This series
5.3 - 5.5 COP32Peer range
5.5 - 5.7 COP3Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
Hydron Module HVS018*****1 residential equipment inspection. ThermalSpec Editorial Photography

How does Hydron Module HVS018*****1 rank across federal compliance and ENERGY STAR cohorts?

Hydron Module HVS018*****1 ranks #36 of 1,730 (tied with 14 others at 5.30 COP, top 2.9%, more efficient than 97.1% of certified series) for Max COP (+0.80 COP vs 4.50 COP category median) across 2 certified SKU combinations. Open Loop Water-to-Air unit delivering 5.3 COP and 30.5 EER across closed- or open-loop residential piping.

Hydron Module HVS018*****1 Cohort Metrics vs. Geothermal Heat Pump Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max COP) #36 of 1,730 (Top 2.9%, 15 tied) +0.80 COP vs 4.50 COP category median
Closed/Open Loop EER vs Cohort 30.5 EER +5.90 EER vs 24.6 EER median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
ENERGY STAR Most Efficient Criteria MOST EFFICIENT Max COP 5.3 / Max EER 30.5 (Open Loop Water-to-Air)
EPA AIM Act Refrigerant Transition VERIFY OEM SPEC Dataset refrigerant: R-410A

How much annual energy and operating cost does Hydron Module HVS018*****1 require?

Modeled utility figures for Hydron Module HVS018*****1 (Hydron Module) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max COP ratings.

Heat_kWh = 50,000 kBTU / (5.3 COP * 3.412) | Cool_kWh = 36,000 BTU * 1,000 hrs / (30.5 EER * 1,000)

50 MMBtu heating + 36k BTU cooling at US median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
Ground-Source Heating Electricity2,765 kWh/yr$452/yr
Ground-Source Cooling Electricity (1,000 hrs)1,180 kWh/yr$193/yr
Total Annual Geothermal Operating Cost$644/yrState range: $502 to $1,861
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to Hydron Module HVS018*****1?

Showing 2 certified indoor-outdoor coil combinations from 2 total AHRI matched records filed for Hydron Module HVS018*****1 (PD ID 2546230).

HVS018*****1 Matched AHRI Coil —
HVS018*****1 Matched AHRI Coil —

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Hydron Module HVS018*****1, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Hydron Module HVS018*****1: headline Max COP reflects peak tested matches among 2 SKUs, not lower-rated sizes.
  • Catalog specs for Hydron Module HVS018*****1 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal Hydron Module HVS018*****1 fitSingle-family replacement needing documented ENERGY STAR PD ID 2546230 with matching indoor air handler.
Skip Hydron Module HVS018*****1 ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable geothermal heat pump models deliver similar efficiency?

Compare Hydron Module HVS018*****1 against Enertech EVS018* and closely matched geothermal heat pump units sharing similar Max COP output and BTU tonnage.

Enertech EVS018*

5.3 COP · 33.6 EER · 2 combos

GeoComfort GVS018*

5.3 COP · 30.5 EER · 2 combos

GeoComfort GVS018*****1

5.3 COP · 30.5 EER · 2 combos

GeoComfort GXT024D

5.3 COP · 31.0 EER · 2 combos

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Hydron Module HVS018*****1 compare with peer Geothermal Heat Pump units?

Hydron Module HVS018*****1 holds #36 of 1,730 (Top 2.9%, 15 tied) out of 1,730 verified geothermal heat pump models (+0.80 COP vs 4.50 COP category median), spanning 2 certified SKUs up to 5.3 COP. Closest same-cohort alternatives include Enertech EVS018*.

DOE Regions

Where is Hydron Module HVS018*****1 compliant for 2026 US installation?

Hydron Module HVS018*****1: ENERGY STAR certified residential HVAC model. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Hydron Module HVS018*****1 model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Hydron Module HVS018*****1 runs 2,765 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Hydron Module HVS018*****1 cover?

Hydron Module HVS018*****1 covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Hydron Module HVS018*****1 handle extreme weather or cold snaps?

Hydron Module HVS018*****1 is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Hydron Module HVS018*****1?

Hydron Module HVS018*****1 specifies R-410A compliance (PD ID 2546230); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 2 certified SKUs in Hydron Module HVS018*****1 reach 5.3 COP?

Peak 5.3 COP represents the top tested AHRI pairing for Hydron Module HVS018*****1 (PD ID 2546230); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Hydron Module HVS018*****1?

Hydron Module HVS018*****1 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Enertech EVS018*.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros