Century MWM120A — Geothermal Heat Pump Specifications
Century MWM120A (Geothermal Heat Pump, PD ID 4512449) holds 1 ENERGY STAR certified SKU rated at 4.1 COP — #1,503 of 1,730 (120 tied, beats 6.2% of peers), -0.40 COP. ENERGY STAR certified residential HVAC model. Century MWM120A — Geothermal Heat Pump Specifications benchmarks residential systems using Heating COP set at 4.1 COP and Cohort Rank set at #1,503/1,730.
- Heating COP
- 4.1 COP
- Cohort Rank
- #1,503/1,730
- Verified Combos
- 1 SKU
- Sample PD ID
- 4512449
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 3.9 - 4.1 COP | 228 | This series |
| 4.1 - 4.3 COP | 329 | Peer range |
| 4.3 - 4.5 COP | 251 | Peer range |
| 4.5 - 4.7 COP | 296 | Peer range |
| 4.7 - 4.9 COP | 244 | Peer range |
| 4.9 - 5.1 COP | 310 | Peer range |
| 5.1 - 5.3 COP | 37 | Peer range |
| 5.3 - 5.5 COP | 32 | Peer range |
| 5.5 - 5.7 COP | 3 | Peer range |
How does Century MWM120A rank across federal compliance and ENERGY STAR cohorts?
Century MWM120A ranks #1,503 of 1,730 (tied with 119 others at 4.10 COP, more efficient than 6.2% of certified series) for Max COP (-0.40 COP vs 4.50 COP category median) across 1 certified SKU combination. Open Loop Water-to-Water unit delivering 4.1 COP and 23.9 EER across closed- or open-loop residential piping. Zero CPSC residential HVAC recall filings match Century in ThermalSpec's current SaferProducts feed.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max COP) | #1,503 of 1,730 (120 tied, beats 6.2% of peers) | -0.40 COP vs 4.50 COP category median |
| Closed/Open Loop EER vs Cohort | 23.9 EER | -0.70 EER vs 24.6 EER median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| ENERGY STAR Most Efficient Criteria | MOST EFFICIENT | Max COP 4.1 / Max EER 23.9 (Open Loop Water-to-Water) |
| EPA AIM Act Refrigerant Transition | VERIFY OEM SPEC | Dataset refrigerant: Other |
How much annual energy and operating cost does Century MWM120A require?
Modeled utility figures for Century MWM120A (Century) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max COP ratings.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Ground-Source Heating Electricity | 3,574 kWh/yr | $584/yr |
| Ground-Source Cooling Electricity (1,000 hrs) | 1,506 kWh/yr | $246/yr |
| Total Annual Geothermal Operating Cost | $830/yr | State range: $646 to $2,397 |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to Century MWM120A?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Century MWM120A (PD ID 4512449).
| MWM120A | Matched AHRI Coil | — |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Century MWM120A, review 2 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Century MWM120A: headline Max COP reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Century MWM120A exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Century MWM120A fit | Single-family replacement needing documented ENERGY STAR PD ID 4512449 with matching indoor air handler. |
| Skip Century MWM120A if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable geothermal heat pump models deliver similar efficiency?
Compare Century MWM120A against 5 SERIES INDOOR SPLITS NSZ070H1 and closely matched geothermal heat pump units sharing similar Max COP output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Century MWM120A compare with peer Geothermal Heat Pump units?
Century MWM120A holds #1,503 of 1,730 (120 tied, beats 6.2% of peers) out of 1,730 verified geothermal heat pump models (-0.40 COP vs 4.50 COP category median), spanning 1 certified SKU up to 4.1 COP. Closest same-cohort alternatives include 5 SERIES INDOOR SPLITS NSZ070H1.
Where is Century MWM120A compliant for 2026 US installation?
Century MWM120A: ENERGY STAR certified residential HVAC model. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Century MWM120A model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Century MWM120A runs 3,574 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does Century MWM120A cover?
Century MWM120A covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Century MWM120A handle extreme weather or cold snaps?
Century MWM120A is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.
What refrigerant class and 2026 tax credit rules govern Century MWM120A?
Century MWM120A specifies Other compliance (PD ID 4512449); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in Century MWM120A reach 4.1 COP?
Peak 4.1 COP represents the top tested AHRI pairing for Century MWM120A (PD ID 4512449); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Century MWM120A?
Century MWM120A requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include 5 SERIES INDOOR SPLITS NSZ070H1.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.