Skip to main content
Century | Geothermal Heat Pumps

Century Geothermal Heat Pumps — ENERGY STAR Certified Models

ThermalSpec indexes 20 Century geothermal heat pumps models spanning Residential capacities, anchored by HZS024B (5.2 COP) and HZS060B (4.0 COP). Century Geothermal Heat Pumps — ENERGY STAR Certified Models benchmarks residential systems using Certified Models set at 20 and Rating Span set at 4.0 COP - 5.2 COP. Values trace to primary federal, state, or OEM filings supporting Century Geothermal Heat Pumps — ENERGY STAR Certified Models across single-family housing.

Certified Models
20
Rating Span
4.0 COP - 5.2 COP
Capacity Range
Residential capacities
AHRI Combinations
54
Cold Climate Units
0
Category Median
4.5 COP
Residential air handler cabinet with galvanized ductwork and brazed copper piping
Century Geothermal Heat Pumps — ENERGY STAR Certified Models editorial reference. ThermalSpec Editorial Photography

How does Century's geothermal heat pumps portfolio cover capacity, refrigerants, and safety?

Century covers Residential capacities in geothermal heat pumps across 20 canonical models and 54 AHRI combinations, with 0 Cold Climate certified models and Other, R-410A. Ratings span 4.0 COP up to 5.2 COP (category median 4.5 COP, certified through 2024-12-11). CPSC records show 0 residential HVAC recall notices matching Century; check exact AHRI matched pairings on individual model sheets.

Showing 20 entries

Which verified records belong in Century Geothermal Heat Pumps — ENERGY STAR Certified Models?

Compare all 20 verified entries below. Click any column header to sort numerically or alphabetically, then select any row for full benchmark citations.

All 20 ENERGY STAR Century Geothermal Heat Pumps Models
Century HZS024B 4.7 COP 27.5 EER Open Loop Water-to-Air 13
Century MJN024A 4.9 COP 27.7 EER Open Loop Water-to-Air 4
Century HZS036B 4.7 COP 26.6 EER Open Loop Water-to-Air 4
Century MJN036A 4.7 COP 28.1 EER Open Loop Water-to-Air 4
Century HZS048B 4.4 COP 26.2 EER Open Loop Water-to-Air 3
Century ME(L/R/B/P/D/N/T/K)024A 5.2 COP 29.6 EER Open Loop Water-to-Air 2
Century ME(L/R/B/P/D/N/T/K)048A 5.1 COP 30.5 EER Open Loop Water-to-Air 2
Century ME(L/R/B/P/D/N/T/K)036A 5.0 COP 28.5 EER Open Loop Water-to-Air 2
Century MZ(L/R/B/P/T/K)024A 4.8 COP 26.9 EER Open Loop Water-to-Air 2
Century ME(L/R/B/P/D/N/T/K)060A 4.6 COP 27.8 EER Open Loop Water-to-Air 2
Century MZ(L/R/B/P/T/K)060A 4.6 COP 25.9 EER Open Loop Water-to-Air 2
Century ME(L/R/B/P/D/N/T/K)072A 4.5 COP 23.9 EER Open Loop Water-to-Air 2
Century MJN048A 4.5 COP 26.8 EER Open Loop Water-to-Air 2
Century MJN060A 4.4 COP 25.8 EER Open Loop Water-to-Air 2
Century MZ(L/R/B/P/T/K)048A 4.4 COP 25.7 EER Open Loop Water-to-Air 2
Century MZ(L/R/B/P/T/K)036A 4.3 COP 23.1 EER Open Loop Water-to-Air 2
Century MZ(L/R/B/P/T/K)042A 4.4 COP 25.7 EER Open Loop Water-to-Air 1
Century MZ(L/R/B/P/T/K)030A 4.3 COP 24.1 EER Open Loop Water-to-Air 1
Century MWM120A 4.1 COP 23.9 EER Open Loop Water-to-Water 1
Century HZS060B 4.0 COP 21.5 EER Open Loop Water-to-Air 1

Which top Century geothermal heat pumps anchor this lineup?

Select any of the 4 verified listings below to open detailed specifications, safety boundaries, and source links.

Century4.7 COP

Century HZS024B

27.5 EER | Open Loop Water-to-Air | 13 SKUs

Century4.9 COP

Century MJN024A

27.7 EER | Open Loop Water-to-Air | 4 SKUs

Century4.7 COP

Century HZS036B

26.6 EER | Open Loop Water-to-Air | 4 SKUs

Century4.7 COP

Century MJN036A

28.1 EER | Open Loop Water-to-Air | 4 SKUs

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Century Geothermal Heat Pumps, review 3 important real-world limits and verify local licensing and permit rules directly.

  • Cohort spread across Century: 4.0 COP entry units differ substantially from flagship HZS024B (5.2 COP).
  • Verify indoor coil AHRI pairing on PD ID 3845849 and 3998115 before pulling state mechanical permits.
  • Equipment catalog metrics exclude ductwork upgrades, A2L leak sensors where applicable, and municipal inspection fees.
Homeowner ScenarioRecommended Verification Path
Best fit for CenturyHomes matched to Residential capacities seeking Other, R-410A compliance and verified ENERGY STAR documentation.
Skip or verify further ifExisting ductwork pushes total static pressure above 0.50 in. w.c. or 3-phase commercial wiring is present.

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Century Peak

Which Century geothermal heat pumps model reaches the highest 5.2 COP rating?

HZS024B tops Century's 20 ENERGY STAR geothermal heat pumps models at 5.2 COP across 13 AHRI matches (PD ID 3845849).

Lineup Span

How broad is Century's geothermal heat pumps efficiency and BTU range?

Century spans 4.0 COP (HZS060B) up to 5.2 COP (HZS024B) across Residential capacities, compared with the 4.5 COP category median.

AHRI Pairs

How many AHRI combinations support Century geothermal heat pumps?

Current ENERGY STAR datasets document 54 verified indoor-outdoor AHRI combinations distributed across 20 canonical Century models.

Cold / Fuel

What refrigerants or fuels power Century geothermal heat pumps?

Century geothermal heat pumps listings record Other, R-410A, with 0 Cold Climate certified models inside the geothermal heat pumps cohort.

DOE Regions

Where are Century geothermal heat pumps compliant under 2026 federal rules?

Models meeting 13.4 SEER2 qualify in the North; 14.3 SEER2 (plus 11.7 EER2 or 9.8 at 15.2+ SEER2) is needed for Southwest split cooling, while split heat pumps require 14.3 SEER2 / 7.5 HSPF2 nationwide.

CPSC Recalls

Are any CPSC safety recalls linked to Century residential HVAC products?

ThermalSpec counts 0 residential HVAC CPSC filings referencing Century; verify model serial prefixes at /recalls/ before installation or service.

25C Tax Credit

Do Century geothermal heat pumps receive federal Section 25C credits in 2026?

No — IRS Section 25C credits terminated December 31, 2025 ($0 federal tax credit for Century in 2026). Check state HOMES/HEAR and local utility ENERGY STAR rebates using PD ID 3845849.

Sizing Rule

How should homeowners select among Century's 20 geothermal heat pumps models?

Match Century model capacity (Residential capacities) using an ACCA Manual J room-by-room heat load and <= 0.50 in. w.c. static pressure check rather than old unit tonnage.

Sources

Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 6 pages.

Comparable HVAC Climate & Cost Metros