Residential Boiler · IBC Technologies · 1 ENERGY STAR Combinations

IBC Technologies SFC 160* — Residential Boiler Specifications

IBC Technologies SFC 160* (Residential Boiler, PD ID 2538517) holds 1 ENERGY STAR certified SKU rated at 94.0% AFUE — #455 of 663 (19 tied, beats 28.7% of peers), -1.00% AFUE. Condensing ENERGY STAR residential boiler (94.0% AFUE; exceeds 84% federal gas boiler floor). IBC Technologies SFC 160* — Residential Boiler Specifications benchmarks residential systems using Thermal Efficiency set at 94.0% AFUE and Cohort Rank set at #455/663.

Thermal Efficiency
94.0% AFUE
Cohort Rank
#455/663
Verified Combos
1 SKU
Sample PD ID
2538517
Residential Boiler Efficiency Spread across 663 certified series (87.0 to 97.0% AFUE)
IBC Technologies SFC 160* Residential Boiler Efficiency Spread Distribution Distribution of 663 certified series from 87.0 to 97.0% AFUE. IBC Technologies SFC 160* sits at 94.0% AFUE; typical midpoint is 95.0% AFUE. 148 87.0 0 88.1 22 89.2 13 90.3 3 91.4 4 92.6 19 93.7 402 94.8 52 95.9 Median 95.0% AFUE This model: 94.0% AFUE (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
87.0 - 88.1% AFUE148Peer range
88.1 - 89.2% AFUE0Peer range
89.2 - 90.3% AFUE22Peer range
90.3 - 91.4% AFUE13Peer range
91.4 - 92.6% AFUE3Peer range
92.6 - 93.7% AFUE4Peer range
93.7 - 94.8% AFUE19This series
94.8 - 95.9% AFUE402Peer range
95.9 - 97.0% AFUE52Peer range
Residential air handler cabinet with galvanized ductwork and brazed copper piping
IBC Technologies SFC 160* residential equipment inspection. ThermalSpec Editorial Photography

How does IBC Technologies SFC 160* rank across federal compliance and ENERGY STAR cohorts?

IBC Technologies SFC 160* ranks #455 of 663 (tied with 18 others at 94.0% AFUE, more efficient than 28.7% of certified series) for Max AFUE (-1.00% AFUE vs 95.0% AFUE category median) across 1 certified SKU combination. Condensing Natural Gas, Propane Gas series at 94.0% AFUE (+14.0 pts above federal baseline), needing Schedule 40 PVC venting and condensate drainage with ENERGY STAR qualification dated 2023-06-25.

IBC Technologies SFC 160* Cohort Metrics vs. Residential Boiler Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max AFUE) #455 of 663 (19 tied, beats 28.7% of peers) -1.00% AFUE vs 95.0% AFUE category median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Federal Residential Boiler Minimum PASS Rated 94.0% AFUE vs 84% federal gas hot-water boiler baseline
Condensing Hydronic Design CONDENSING Extracts latent flue heat below 140F return water temp

How much annual energy and operating cost does IBC Technologies SFC 160* require?

Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, IBC Technologies SFC 160* estimates reflect 1 certified SKU combination tested under PD ID 2538517.

Annual_Therms = (50 MMBtu * 10 therms/MMBtu) / (94.0% / 100)

50 MMBtu heating season at EIA US median $1.45/therm ($15.04/Mcf; range $0.74 ID to $5.05 HI)

Operating BasisEstimated ValueSource Basis
Annual Natural Gas Consumption (50 MMBtu)531.9 therms/yr6,223 lb CO2/yr (11.7 lb/therm)
Estimated Annual Fuel Cost (US Median)$771/yrState range: $394 (ID) to $2,686 (HI)
Fuel Saved vs 80% AFUE Baseline93.1 therms/yr$135/yr saved
80% AFUE B-Vent Chimney vs. 96% AFUE Condensing PVC Two-Pipe
80% AFUE vs 96% AFUE Furnace Heat Exchanger and Venting Architecture Side-by-side schematic comparing an 80% AFUE Type B metal chimney furnace against a 96% AFUE condensing secondary heat exchanger with PVC intake/exhaust and condensate trap. 80% AFUE Non-Condensing Type B Single Primary Exchanger 20% Flue Loss (Hot Chimney) No condensate drain required 96% AFUE Condensing PVC In PVC Out Primary + Secondary SS Coil -16.7% Annual Fuel Burn vs 80% Requires Schedule 40 PVC + Condensate Trap

Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.

Which AHRI certified SKU combinations belong to IBC Technologies SFC 160*?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for IBC Technologies SFC 160* (PD ID 2538517).

SFC 160* Matched AHRI Coil — / 94.0% AFUE

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on IBC Technologies SFC 160*, review 3 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across IBC Technologies SFC 160*: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for IBC Technologies SFC 160* exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
  • IBC Technologies SFC 160* condensing combustion at 94.0% AFUE requires Schedule 40 PVC venting and freeze-safe condensate traps.
Homeowner ScenarioRecommended Verification Path
Ideal IBC Technologies SFC 160* fitSingle-family replacement needing documented ENERGY STAR PD ID 2538517 with matching indoor air handler.
Skip IBC Technologies SFC 160* ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable residential boiler models deliver similar efficiency?

Compare IBC Technologies SFC 160* against Eco-King C100 and closely matched residential boiler units sharing similar Max AFUE output and BTU tonnage.

Eco-King C100

94.0% AFUE · Natural Gas · 1 combos

Eco-King C140

94.0% AFUE · Natural Gas · 1 combos

Eco-King C200

94.0% AFUE · Natural Gas · 1 combos

Eco-King H100

94.0% AFUE · Natural Gas · 1 combos

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does IBC Technologies SFC 160* compare with peer Residential Boiler units?

IBC Technologies SFC 160* holds #455 of 663 (19 tied, beats 28.7% of peers) out of 663 verified residential boiler models (-1.00% AFUE vs 95.0% AFUE category median), spanning 1 certified SKU up to 94.0% AFUE. Closest same-cohort alternatives include Eco-King C100.

DOE Regions

Where is IBC Technologies SFC 160* compliant for 2026 US installation?

IBC Technologies SFC 160*: Condensing ENERGY STAR residential boiler (94.0% AFUE; exceeds 84% federal gas boiler floor). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does IBC Technologies SFC 160* model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, IBC Technologies SFC 160* runs 531.9 therms/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does IBC Technologies SFC 160* cover?

IBC Technologies SFC 160* covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does IBC Technologies SFC 160* handle extreme weather or cold snaps?

IBC Technologies SFC 160* delivers steady fuel combustion independent of outdoor air temperature.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern IBC Technologies SFC 160*?

IBC Technologies SFC 160* specifies sealed combustion compliance (PD ID 2538517); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in IBC Technologies SFC 160* reach 94.0% AFUE?

Peak 94.0% AFUE represents the top tested AHRI pairing for IBC Technologies SFC 160* (PD ID 2538517); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to IBC Technologies SFC 160*?

IBC Technologies SFC 160* requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Eco-King C100.

Sources

Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Boilers Dataset (6rww-hpns) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. Natural Gas Prices — Annual Residential Price by State — U.S. Energy Information Administration (EIA), EIA Natural Gas Annual (retrieved 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros