IBC Technologies Boilers — ENERGY STAR Certified Models
Rated from 94.0% AFUE to 96.0% AFUE over 21 certified combinations, IBC Technologies's 21 residential boilers models use Gas / Propane combustion. IBC Technologies Boilers — ENERGY STAR Certified Models benchmarks residential systems using Certified Models set at 21 and Rating Span set at 94.0% AFUE - 96.0% AFUE. Values trace to primary federal, state, or OEM filings supporting IBC Technologies Boilers — ENERGY STAR Certified Models across single-family housing.
- Certified Models
- 21
- Rating Span
- 94.0% AFUE - 96.0% AFUE
- Capacity Range
- Residential capacities
- AHRI Combinations
- 21
- Cold Climate Units
- 0
- Category Median
- 95.0% AFUE
How does IBC Technologies's boilers portfolio cover capacity, refrigerants, and safety?
IBC Technologies covers Residential capacities in boilers across 21 canonical models and 21 AHRI combinations, with 0 Cold Climate certified models and Gas / Propane combustion. Ratings span 94.0% AFUE up to 96.0% AFUE (category median 95.0% AFUE, certified through 2022-08-19). CPSC records show 0 residential HVAC recall notices matching IBC Technologies; check exact AHRI matched pairings on individual model sheets.
Which verified records belong in IBC Technologies Boilers — ENERGY STAR Certified Models?
Compare all 21 verified entries below. Click any column header to sort numerically or alphabetically, then select any row for full benchmark citations.
| IBC Technologies SFB 99* | 96.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| IBC Technologies SFC 99* | 96.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| IBC Technologies SL 10-85G3 | 96.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| IBC Technologies DC 20-125 | 95.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| IBC Technologies HC 13-50 | 95.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| IBC Technologies HC 20-125 | 95.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| IBC Technologies IBGFSW1-0110 | 95.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| IBC Technologies IBGFSW1-0150 | 95.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| IBC Technologies IBGFSW1-0199 | 95.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| IBC Technologies ICGFSW1-0150 | 95.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| IBC Technologies ICGFSW1-0199 | 95.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| IBC Technologies SFB 120* | 95.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| IBC Technologies SFC 125* | 95.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| IBC Technologies SFC 199* | 95.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| IBC Technologies SL 14-115G3 | 95.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| IBC Technologies SL 20-160G3 | 95.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| IBC Technologies SL 26-260G3 | 95.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| IBC Technologies SL 30-199G3 | 95.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| IBC Technologies DC 33-160 | 94.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| IBC Technologies HC 33-160 | 94.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
| IBC Technologies SFC 160* | 94.0% AFUE | Condensing | Natural Gas, Propane Gas | 1 |
Which top IBC Technologies boilers anchor this lineup?
Select any of the 4 verified listings below to open detailed specifications, safety boundaries, and source links.
IBC Technologies SFB 99*
IBC Technologies SFC 99*
IBC Technologies SL 10-85G3
IBC Technologies DC 20-125
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on IBC Technologies Boilers, review 3 important real-world limits and verify local licensing and permit rules directly.
- Cohort spread across IBC Technologies: 94.0% AFUE entry units differ substantially from flagship SFB 99* (96.0% AFUE).
- Verify indoor coil AHRI pairing on PD ID 2400340 and 2538517 before pulling state mechanical permits.
- Equipment catalog metrics exclude ductwork upgrades, A2L leak sensors where applicable, and municipal inspection fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Best fit for IBC Technologies | Homes matched to Residential capacities seeking Gas / Propane combustion compliance and verified ENERGY STAR documentation. |
| Skip or verify further if | Existing ductwork pushes total static pressure above 0.50 in. w.c. or 3-phase commercial wiring is present. |
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
Which IBC Technologies boilers model reaches the highest 96.0% AFUE rating?
SFB 99* tops IBC Technologies's 21 ENERGY STAR boilers models at 96.0% AFUE across 1 AHRI matches (PD ID 2400340).
How broad is IBC Technologies's boilers efficiency and BTU range?
IBC Technologies spans 94.0% AFUE (SFC 160*) up to 96.0% AFUE (SFB 99*) across Residential capacities, compared with the 95.0% AFUE category median.
How many AHRI combinations support IBC Technologies boilers?
Current ENERGY STAR datasets document 21 verified indoor-outdoor AHRI combinations distributed across 21 canonical IBC Technologies models.
What refrigerants or fuels power IBC Technologies boilers?
IBC Technologies boilers listings record Gas / Propane combustion, with 0 Cold Climate certified models inside the boilers cohort.
Where are IBC Technologies boilers compliant under 2026 federal rules?
Models meeting 13.4 SEER2 qualify in the North; 14.3 SEER2 (plus 11.7 EER2 or 9.8 at 15.2+ SEER2) is needed for Southwest split cooling, while split heat pumps require 14.3 SEER2 / 7.5 HSPF2 nationwide.
Are any CPSC safety recalls linked to IBC Technologies residential HVAC products?
ThermalSpec counts 0 residential HVAC CPSC filings referencing IBC Technologies; verify model serial prefixes at /recalls/ before installation or service.
Do IBC Technologies boilers receive federal Section 25C credits in 2026?
No — IRS Section 25C credits terminated December 31, 2025 ($0 federal tax credit for IBC Technologies in 2026). Check state HOMES/HEAR and local utility ENERGY STAR rebates using PD ID 2400340.
How should homeowners select among IBC Technologies's 21 boilers models?
Match IBC Technologies model capacity (Residential capacities) using an ACCA Manual J room-by-room heat load and <= 0.50 in. w.c. static pressure check rather than old unit tonnage.
Sources
Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Boilers Dataset (6rww-hpns) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 6 pages.