Skip to main content
Smart Thermostat · Vivint · 1 ENERGY STAR Combinations

Vivint TH03 — Smart Thermostat Specifications

Vivint TH03 (Smart Thermostat, PD ID 4481207) holds 1 ENERGY STAR certified SKU rated at 0.09W Standby — #4 of 116 (Top 5.2%, 3 tied), -0.51 W. ENERGY STAR certified connected thermostat evaluated for static temperature accuracy and network standby watts. Vivint TH03 — Smart Thermostat Specifications benchmarks residential systems using Cohort Rank set at #4/116 and Verified Combos set at 1 SKU.

Cohort Rank
#4/116
Verified Combos
1 SKU
Sample PD ID
4481207
Federal AC Minimum
13.4 - 14.3 SEER2
Smart Thermostat Efficiency Spread across 116 certified series (0.0 to 2.6 W)
Vivint TH03 Smart Thermostat Efficiency Spread Distribution Distribution of 116 certified series from 0.0 to 2.6 W. Vivint TH03 sits at 0.09 W; typical midpoint is 0.6 W. 25 0.0 34 0.3 11 0.6 8 0.9 12 1.2 12 1.5 6 1.7 4 2.0 4 2.3 Median 0.6 W This model: 0.09 W (Lower standby draw is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
0.0 - 0.3 W25This series
0.3 - 0.6 W34Peer range
0.6 - 0.9 W11Peer range
0.9 - 1.2 W8Peer range
1.2 - 1.5 W12Peer range
1.5 - 1.7 W12Peer range
1.7 - 2.0 W6Peer range
2.0 - 2.3 W4Peer range
2.3 - 2.6 W4Peer range
Color-coded low-voltage thermostat wires terminated into brass wall plate terminals
Vivint TH03 residential equipment inspection. ThermalSpec Editorial Photography

How does Vivint TH03 rank across federal compliance and ENERGY STAR cohorts?

Vivint TH03 ranks #4 of 116 (tied with 2 others at 0.09 W, top 5.2%, lower standby draw than 94.8% of certified thermostats) for Network Standby (-0.51 W vs 0.60 W category median) across 1 certified SKU combination. Supports Zigbee with +/-0.06 F static accuracy and 0.09 W network standby. Zero CPSC residential HVAC recall filings match Vivint in ThermalSpec's current SaferProducts feed.

Vivint TH03 Cohort Metrics vs. Smart Thermostat Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Network Standby) #4 of 116 (Top 5.2%, 3 tied) -0.51 W vs 0.60 W category median
Static Temp Accuracy +/-0.06 F -0.45 F vs 0.51 F median
Idle-to-Standby Timeout 10.0 min ENERGY STAR CT Spec
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Low Network Standby Power (<= 1.0 W) LOW DRAW Measured 0.09 W average network standby vs 0.6 W category median
Thermostat Static Accuracy (<= 0.5 F) HIGH PRECISION Lab static accuracy +/-0.06 F vs 0.51 F category median
24VAC Common Wire & Control Interfaces CONNECTED Methods: Zigbee; check O (Carrier/Trane) vs B (Rheem/Ruud) reversing valve

How much annual energy and operating cost does Vivint TH03 require?

Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, Vivint TH03 estimates reflect 1 certified SKU combination tested under PD ID 4481207.

Standby_kWh = (0.09 W * 8,760 hrs) / 1,000 | Standby_USD = Standby_kWh * $0.1633/kWh

Continuous 24/7/365 network standby draw priced at US 51-state median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
Continuous Standby Electricity (8,760 hrs)0.79 kWh/yr$0.13/yr
State Standby Cost Spread$0.10 (NV)to $0.37/yr (HI)
Static Control Band (+/-F)+/-0.06 FLower band tightens setpoint deadband cycling
Split Heat Pump Reversing Valve & 24VAC O/B Control Flow
Split Heat Pump Refrigerant Cycle and 24VAC Reversing Valve Path Technical schematic connecting Outdoor Compressor, 4-Way Reversing Valve (O vs B 24VAC coil), TXV Expansion Valve, and Indoor Evaporator A-Coil. Outdoor Condenser COMP 14.3 SEER2 Min 4-Way Valve O = Cool (Carrier/Trane) B = Heat (Rheem/Ruud) TXV / EEV Metering Indoor A-Coil 7.5 HSPF2 Min 24VAC Reversing Valve & Refrigerant Path (Federal Standard) Vapor Suction Line (5/8" to 1-1/8" insulated) <-> Liquid Line (3/8" OD)

Cooling mode energizes O terminal on Carrier, Trane, Lennox, Goodman, and Bosch; Rheem and Ruud energize B on heating.

Which AHRI certified SKU combinations belong to Vivint TH03?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Vivint TH03 (PD ID 4481207).

TH03 Matched AHRI Coil —

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Vivint TH03, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Vivint TH03: headline Network Standby reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for Vivint TH03 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal Vivint TH03 fitSingle-family replacement needing documented ENERGY STAR PD ID 4481207 with matching indoor air handler.
Skip Vivint TH03 ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable smart thermostat models deliver similar efficiency?

Compare Vivint TH03 against Braeburn 7205 and closely matched smart thermostat units sharing similar Network Standby output and BTU tonnage.

Braeburn 7205

0.09 W · +/-1.1 F · Wi-Fi

Verdant VX4-*TR-*

0.09 W · +/-1.79 F · Bluetooth, Zigbee, Other

Google Nest GA0####-**

0.1 W · +/-0.3 F · Wi-Fi

Google Nest GA05###-**

0.1 W · +/-0.09 F · Bluetooth, Other, Wi-Fi

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Vivint TH03 compare with peer Smart Thermostat units?

Vivint TH03 holds #4 of 116 (Top 5.2%, 3 tied) out of 116 verified smart thermostat models (-0.51 W vs 0.60 W category median), spanning 1 certified SKU up to 0.09 W standby. Closest same-cohort alternatives include Braeburn 7205.

DOE Regions

Where is Vivint TH03 compliant for 2026 US installation?

Vivint TH03: ENERGY STAR certified connected thermostat evaluated for static temperature accuracy and network standby watts. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Vivint TH03 model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Vivint TH03 runs 0.79 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Vivint TH03 cover?

Vivint TH03 covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Vivint TH03 handle extreme weather or cold snaps?

Vivint TH03 delivers steady fuel combustion independent of outdoor air temperature.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Vivint TH03?

Vivint TH03 specifies sealed combustion compliance (PD ID 4481207); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in Vivint TH03 reach 0.09 W standby?

Peak 0.09 W standby represents the top tested AHRI pairing for Vivint TH03 (PD ID 4481207); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Vivint TH03?

Vivint TH03 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Braeburn 7205.

Sources

Verified numerical figures and rules trace to the 3 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Smart Thermostats Dataset (7p2p-wkbf) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
  3. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros