tekmar 564 — Smart Thermostat Specifications
tekmar 564 (Smart Thermostat, PD ID 4471363) holds 1 ENERGY STAR certified SKU rated at 1.57W Standby — #93 of 116 (Lower than 19.8% of peers), +0.97 W. ENERGY STAR certified connected thermostat evaluated for static temperature accuracy and network standby watts. tekmar 564 — Smart Thermostat Specifications benchmarks residential systems using Cohort Rank set at #93/116 and Verified Combos set at 1 SKU.
- Cohort Rank
- #93/116
- Verified Combos
- 1 SKU
- Sample PD ID
- 4471363
- Federal AC Minimum
- 13.4 - 14.3 SEER2
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 0.0 - 0.3 W | 25 | Peer range |
| 0.3 - 0.6 W | 34 | Peer range |
| 0.6 - 0.9 W | 11 | Peer range |
| 0.9 - 1.2 W | 8 | Peer range |
| 1.2 - 1.5 W | 12 | Peer range |
| 1.5 - 1.7 W | 12 | This series |
| 1.7 - 2.0 W | 6 | Peer range |
| 2.0 - 2.3 W | 4 | Peer range |
| 2.3 - 2.6 W | 4 | Peer range |
How does tekmar 564 rank across federal compliance and ENERGY STAR cohorts?
tekmar 564 ranks #93 of 116 (lower standby draw than 19.8% of certified thermostats) for Network Standby (+0.97 W vs 0.60 W category median) across 1 certified SKU combination. Supports Wi-Fi with +/-0.59 F static accuracy and 1.57 W network standby. Zero CPSC residential HVAC recall filings match tekmar in ThermalSpec's current SaferProducts feed.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Network Standby) | #93 of 116 (Lower than 19.8% of peers) | +0.97 W vs 0.60 W category median |
| Static Temp Accuracy | +/-0.59 F | +0.08 F vs 0.51 F median |
| Idle-to-Standby Timeout | 60.3 min | ENERGY STAR CT Spec |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Low Network Standby Power (<= 1.0 W) | STANDARD DRAW | Measured 1.57 W average network standby vs 0.6 W category median |
| Thermostat Static Accuracy (<= 0.5 F) | STANDARD | Lab static accuracy +/-0.59 F vs 0.51 F category median |
| 24VAC Common Wire & Control Interfaces | CONNECTED | Methods: Wi-Fi; check O (Carrier/Trane) vs B (Rheem/Ruud) reversing valve |
How much annual energy and operating cost does tekmar 564 require?
Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, tekmar 564 estimates reflect 1 certified SKU combination tested under PD ID 4471363.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Continuous Standby Electricity (8,760 hrs) | 13.75 kWh/yr | $2.25/yr |
| State Standby Cost Spread | $1.75 (NV) | to $6.49/yr (HI) |
| Static Control Band (+/-F) | +/-0.59 F | Lower band tightens setpoint deadband cycling |
Cooling mode energizes O terminal on Carrier, Trane, Lennox, Goodman, and Bosch; Rheem and Ruud energize B on heating.
Which AHRI certified SKU combinations belong to tekmar 564?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for tekmar 564 (PD ID 4471363).
| 564 | Matched AHRI Coil | — |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on tekmar 564, review 2 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across tekmar 564: headline Network Standby reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for tekmar 564 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal tekmar 564 fit | Single-family replacement needing documented ENERGY STAR PD ID 4471363 with matching indoor air handler. |
| Skip tekmar 564 if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable smart thermostat models deliver similar efficiency?
Compare tekmar 564 against Alarm.com ADC-T40K-HD and closely matched smart thermostat units sharing similar Network Standby output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does tekmar 564 compare with peer Smart Thermostat units?
tekmar 564 holds #93 of 116 (Lower than 19.8% of peers) out of 116 verified smart thermostat models (+0.97 W vs 0.60 W category median), spanning 1 certified SKU up to 1.57 W standby. Closest same-cohort alternatives include Alarm.com ADC-T40K-HD.
Where is tekmar 564 compliant for 2026 US installation?
tekmar 564: ENERGY STAR certified connected thermostat evaluated for static temperature accuracy and network standby watts. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does tekmar 564 model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, tekmar 564 runs 13.75 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does tekmar 564 cover?
tekmar 564 covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does tekmar 564 handle extreme weather or cold snaps?
tekmar 564 delivers steady fuel combustion independent of outdoor air temperature.
What refrigerant class and 2026 tax credit rules govern tekmar 564?
tekmar 564 specifies sealed combustion compliance (PD ID 4471363); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in tekmar 564 reach 1.57 W standby?
Peak 1.57 W standby represents the top tested AHRI pairing for tekmar 564 (PD ID 4471363); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to tekmar 564?
tekmar 564 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Alarm.com ADC-T40K-HD.
Sources
Verified numerical figures and rules trace to the 3 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Smart Thermostats Dataset (7p2p-wkbf) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.