Skip to main content
Smart Thermostat · Resideo · 1 ENERGY STAR Combinations

Resideo TH8732WFH**** — Smart Thermostat Specifications

Resideo TH8732WFH**** (Smart Thermostat, PD ID 2344270) holds 1 ENERGY STAR certified SKU rated at 0.18W Standby — #21 of 116 (Top 19%, 2 tied), -0.42 W. ENERGY STAR certified connected thermostat evaluated for static temperature accuracy and network standby watts. Resideo TH8732WFH**** — Smart Thermostat Specifications benchmarks residential systems using Cohort Rank set at #21/116 and Verified Combos set at 1 SKU.

Cohort Rank
#21/116
Verified Combos
1 SKU
Sample PD ID
2344270
Federal AC Minimum
13.4 - 14.3 SEER2
Smart Thermostat Efficiency Spread across 116 certified series (0.0 to 2.6 W)
Resideo TH8732WFH**** Smart Thermostat Efficiency Spread Distribution Distribution of 116 certified series from 0.0 to 2.6 W. Resideo TH8732WFH**** sits at 0.18 W; typical midpoint is 0.6 W. 25 0.0 34 0.3 11 0.6 8 0.9 12 1.2 12 1.5 6 1.7 4 2.0 4 2.3 Median 0.6 W This model: 0.18 W (Lower standby draw is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
0.0 - 0.3 W25This series
0.3 - 0.6 W34Peer range
0.6 - 0.9 W11Peer range
0.9 - 1.2 W8Peer range
1.2 - 1.5 W12Peer range
1.5 - 1.7 W12Peer range
1.7 - 2.0 W6Peer range
2.0 - 2.3 W4Peer range
2.3 - 2.6 W4Peer range
Color-coded low-voltage thermostat wires terminated into brass wall plate terminals
Resideo TH8732WFH**** residential equipment inspection. ThermalSpec Editorial Photography

How does Resideo TH8732WFH**** rank across federal compliance and ENERGY STAR cohorts?

Resideo TH8732WFH**** ranks #21 of 116 (tied with 1 other at 0.18 W, top 19%, lower standby draw than 81% of certified thermostats) for Network Standby (-0.42 W vs 0.60 W category median) across 1 certified SKU combination. Supports Wi-Fi with +/-0.37 F static accuracy and 0.18 W network standby. Zero CPSC residential HVAC recall filings match Resideo in ThermalSpec's current SaferProducts feed.

Resideo TH8732WFH**** Cohort Metrics vs. Smart Thermostat Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Network Standby) #21 of 116 (Top 19%, 2 tied) -0.42 W vs 0.60 W category median
Static Temp Accuracy +/-0.37 F -0.14 F vs 0.51 F median
Idle-to-Standby Timeout 41.0 min ENERGY STAR CT Spec
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Low Network Standby Power (<= 1.0 W) LOW DRAW Measured 0.18 W average network standby vs 0.6 W category median
Thermostat Static Accuracy (<= 0.5 F) HIGH PRECISION Lab static accuracy +/-0.37 F vs 0.51 F category median
24VAC Common Wire & Control Interfaces CONNECTED Methods: Wi-Fi; check O (Carrier/Trane) vs B (Rheem/Ruud) reversing valve

How much annual energy and operating cost does Resideo TH8732WFH**** require?

Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, Resideo TH8732WFH**** estimates reflect 1 certified SKU combination tested under PD ID 2344270.

Standby_kWh = (0.18 W * 8,760 hrs) / 1,000 | Standby_USD = Standby_kWh * $0.1633/kWh

Continuous 24/7/365 network standby draw priced at US 51-state median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
Continuous Standby Electricity (8,760 hrs)1.58 kWh/yr$0.26/yr
State Standby Cost Spread$0.20 (NV)to $0.75/yr (HI)
Static Control Band (+/-F)+/-0.37 FLower band tightens setpoint deadband cycling
Split Heat Pump Reversing Valve & 24VAC O/B Control Flow
Split Heat Pump Refrigerant Cycle and 24VAC Reversing Valve Path Technical schematic connecting Outdoor Compressor, 4-Way Reversing Valve (O vs B 24VAC coil), TXV Expansion Valve, and Indoor Evaporator A-Coil. Outdoor Condenser COMP 14.3 SEER2 Min 4-Way Valve O = Cool (Carrier/Trane) B = Heat (Rheem/Ruud) TXV / EEV Metering Indoor A-Coil 7.5 HSPF2 Min 24VAC Reversing Valve & Refrigerant Path (Federal Standard) Vapor Suction Line (5/8" to 1-1/8" insulated) <-> Liquid Line (3/8" OD)

Cooling mode energizes O terminal on Carrier, Trane, Lennox, Goodman, and Bosch; Rheem and Ruud energize B on heating.

Which AHRI certified SKU combinations belong to Resideo TH8732WFH****?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Resideo TH8732WFH**** (PD ID 2344270).

TH8732WFH**** Matched AHRI Coil —

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Resideo TH8732WFH****, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Resideo TH8732WFH****: headline Network Standby reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for Resideo TH8732WFH**** exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal Resideo TH8732WFH**** fitSingle-family replacement needing documented ENERGY STAR PD ID 2344270 with matching indoor air handler.
Skip Resideo TH8732WFH**** ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable smart thermostat models deliver similar efficiency?

Compare Resideo TH8732WFH**** against Verdant VX3-TR-* and closely matched smart thermostat units sharing similar Network Standby output and BTU tonnage.

Verdant VX3-TR-*

0.18 W · +/-0.26 F · Bluetooth, Zigbee, Other

Alarm.com TH6320ZW****

0.17 W · +/-0.59 F · Z-Wave

Ecobee EB-STATE5*

0.17 W · +/-1.01 F · Bluetooth, Wi-Fi, Other

Honeywell Home TH6320ZW****

0.17 W · +/-0.59 F · Z-Wave

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Resideo TH8732WFH**** compare with peer Smart Thermostat units?

Resideo TH8732WFH**** holds #21 of 116 (Top 19%, 2 tied) out of 116 verified smart thermostat models (-0.42 W vs 0.60 W category median), spanning 1 certified SKU up to 0.18 W standby. Closest same-cohort alternatives include Verdant VX3-TR-*.

DOE Regions

Where is Resideo TH8732WFH**** compliant for 2026 US installation?

Resideo TH8732WFH****: ENERGY STAR certified connected thermostat evaluated for static temperature accuracy and network standby watts. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Resideo TH8732WFH**** model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Resideo TH8732WFH**** runs 1.58 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Resideo TH8732WFH**** cover?

Resideo TH8732WFH**** covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Resideo TH8732WFH**** handle extreme weather or cold snaps?

Resideo TH8732WFH**** delivers steady fuel combustion independent of outdoor air temperature.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Resideo TH8732WFH****?

Resideo TH8732WFH**** specifies sealed combustion compliance (PD ID 2344270); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in Resideo TH8732WFH**** reach 0.18 W standby?

Peak 0.18 W standby represents the top tested AHRI pairing for Resideo TH8732WFH**** (PD ID 2344270); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Resideo TH8732WFH****?

Resideo TH8732WFH**** requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Verdant VX3-TR-*.

Sources

Verified numerical figures and rules trace to the 3 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Smart Thermostats Dataset (7p2p-wkbf) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
  3. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros