Resideo RCHT8610WF**** — Smart Thermostat Specifications

Resideo RCHT8610WF**** (Smart Thermostat, PD ID 2344268) holds 1 ENERGY STAR certified SKU rated at 0.36W Standby — #30 of 116 (Top 30.2%, 6 tied), -0.24 W. ENERGY STAR certified connected thermostat evaluated for static temperature accuracy and network standby watts. Resideo RCHT8610WF**** — Smart Thermostat Specifications benchmarks residential systems using Cohort Rank set at #30/116 and Verified Combos set at 1 SKU.

Cohort Rank
#30/116
Verified Combos
1 SKU
Sample PD ID
2344268
Federal AC Minimum
13.4 - 14.3 SEER2
Smart Thermostat Efficiency Spread across 116 certified series (0.0 to 2.6 W)
Resideo RCHT8610WF**** Smart Thermostat Efficiency Spread Distribution Distribution of 116 certified series from 0.0 to 2.6 W. Resideo RCHT8610WF**** sits at 0.36 W; typical midpoint is 0.6 W. 25 0.0 34 0.3 11 0.6 8 0.9 12 1.2 12 1.5 6 1.7 4 2.0 4 2.3 Median 0.6 W This model: 0.36 W (Lower standby draw is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
0.0 - 0.3 W25Peer range
0.3 - 0.6 W34This series
0.6 - 0.9 W11Peer range
0.9 - 1.2 W8Peer range
1.2 - 1.5 W12Peer range
1.5 - 1.7 W12Peer range
1.7 - 2.0 W6Peer range
2.0 - 2.3 W4Peer range
2.3 - 2.6 W4Peer range
Color-coded low-voltage thermostat wires terminated into brass wall plate terminals
Resideo RCHT8610WF**** residential equipment inspection. ThermalSpec Editorial Photography

How does Resideo RCHT8610WF**** rank across federal compliance and ENERGY STAR cohorts?

Resideo RCHT8610WF**** ranks #30 of 116 (tied with 5 others at 0.36 W, top 30.2%, lower standby draw than 69.8% of certified thermostats) for Network Standby (-0.24 W vs 0.60 W category median) across 1 certified SKU combination. Supports Wi-Fi with +/-0.87 F static accuracy and 0.36 W network standby. Zero CPSC residential HVAC recall filings match Resideo in ThermalSpec's current SaferProducts feed.

Resideo RCHT8610WF**** Cohort Metrics vs. Smart Thermostat Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Network Standby) #30 of 116 (Top 30.2%, 6 tied) -0.24 W vs 0.60 W category median
Static Temp Accuracy +/-0.87 F +0.36 F vs 0.51 F median
Idle-to-Standby Timeout 49.0 min ENERGY STAR CT Spec
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Low Network Standby Power (<= 1.0 W) LOW DRAW Measured 0.36 W average network standby vs 0.6 W category median
Thermostat Static Accuracy (<= 0.5 F) STANDARD Lab static accuracy +/-0.87 F vs 0.51 F category median
24VAC Common Wire & Control Interfaces CONNECTED Methods: Wi-Fi; check O (Carrier/Trane) vs B (Rheem/Ruud) reversing valve

How much annual energy and operating cost does Resideo RCHT8610WF**** require?

Annual cost outputs combine Resideo RCHT8610WF****'s 0.36 W rating and EIA national tariffs across single-family runtime hours.

Standby_kWh = (0.36 W * 8,760 hrs) / 1,000 | Standby_USD = Standby_kWh * $0.1633/kWh

Continuous 24/7/365 network standby draw priced at US 51-state median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
Continuous Standby Electricity (8,760 hrs)3.15 kWh/yr$0.51/yr
State Standby Cost Spread$0.40 (NV)to $1.49/yr (HI)
Static Control Band (+/-F)+/-0.87 FLower band tightens setpoint deadband cycling
Split Heat Pump Reversing Valve & 24VAC O/B Control Flow
Split Heat Pump Refrigerant Cycle and 24VAC Reversing Valve Path Technical schematic connecting Outdoor Compressor, 4-Way Reversing Valve (O vs B 24VAC coil), TXV Expansion Valve, and Indoor Evaporator A-Coil. Outdoor Condenser COMP 14.3 SEER2 Min 4-Way Valve O = Cool (Carrier/Trane) B = Heat (Rheem/Ruud) TXV / EEV Metering Indoor A-Coil 7.5 HSPF2 Min 24VAC Reversing Valve & Refrigerant Path (Federal Standard) Vapor Suction Line (5/8" to 1-1/8" insulated) <-> Liquid Line (3/8" OD)

Cooling mode energizes O terminal on Carrier, Trane, Lennox, Goodman, and Bosch; Rheem and Ruud energize B on heating.

Which AHRI certified SKU combinations belong to Resideo RCHT8610WF****?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Resideo RCHT8610WF**** (PD ID 2344268).

RCHT8610WF**** Matched AHRI Coil —

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Resideo RCHT8610WF****, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Resideo RCHT8610WF****: headline Network Standby reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for Resideo RCHT8610WF**** exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal Resideo RCHT8610WF**** fitSingle-family replacement needing documented ENERGY STAR PD ID 2344268 with matching indoor air handler.
Skip Resideo RCHT8610WF**** ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable smart thermostat models deliver similar efficiency?

Compare Resideo RCHT8610WF**** against Bryant TSTATBB* and closely matched smart thermostat units sharing similar Network Standby output and BTU tonnage.

Bryant TSTATBB*

0.36 W · +/-0.29 F · Wi-Fi

Carrier TSTATCC*

0.36 W · +/-0.29 F · Wi-Fi

First Alert RCHT8610WF****

0.36 W · +/-0.87 F · Wi-Fi

Ion TSTATII*

0.36 W · +/-0.29 F · Wi-Fi

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Resideo RCHT8610WF**** compare with peer Smart Thermostat units?

Resideo RCHT8610WF**** holds #30 of 116 (Top 30.2%, 6 tied) out of 116 verified smart thermostat models (-0.24 W vs 0.60 W category median), spanning 1 certified SKU up to 0.36 W standby. Closest same-cohort alternatives include Bryant TSTATBB*.

DOE Regions

Where is Resideo RCHT8610WF**** compliant for 2026 US installation?

Resideo RCHT8610WF****: ENERGY STAR certified connected thermostat evaluated for static temperature accuracy and network standby watts. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Resideo RCHT8610WF**** model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Resideo RCHT8610WF**** runs 3.15 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Resideo RCHT8610WF**** cover?

Resideo RCHT8610WF**** covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Resideo RCHT8610WF**** handle extreme weather or cold snaps?

Resideo RCHT8610WF**** delivers steady fuel combustion independent of outdoor air temperature.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Resideo RCHT8610WF****?

Resideo RCHT8610WF**** specifies sealed combustion compliance (PD ID 2344268); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in Resideo RCHT8610WF**** reach 0.36 W standby?

Peak 0.36 W standby represents the top tested AHRI pairing for Resideo RCHT8610WF**** (PD ID 2344268); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Resideo RCHT8610WF****?

Resideo RCHT8610WF**** requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Bryant TSTATBB*.

Sources

Verified numerical figures and rules trace to the 3 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Smart Thermostats Dataset (7p2p-wkbf) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
  3. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.