Pro1 CT855iSH — Smart Thermostat Specifications
Pro1 CT855iSH (Smart Thermostat, PD ID 2383693) holds 1 ENERGY STAR certified SKU rated at 0.47W Standby — #46 of 116 (Top 42.2%, 4 tied), -0.13 W. ENERGY STAR certified connected thermostat evaluated for static temperature accuracy and network standby watts. Pro1 CT855iSH — Smart Thermostat Specifications benchmarks residential systems using Cohort Rank set at #46/116 and Verified Combos set at 1 SKU.
- Cohort Rank
- #46/116
- Verified Combos
- 1 SKU
- Sample PD ID
- 2383693
- Federal AC Minimum
- 13.4 - 14.3 SEER2
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 0.0 - 0.3 W | 25 | Peer range |
| 0.3 - 0.6 W | 34 | This series |
| 0.6 - 0.9 W | 11 | Peer range |
| 0.9 - 1.2 W | 8 | Peer range |
| 1.2 - 1.5 W | 12 | Peer range |
| 1.5 - 1.7 W | 12 | Peer range |
| 1.7 - 2.0 W | 6 | Peer range |
| 2.0 - 2.3 W | 4 | Peer range |
| 2.3 - 2.6 W | 4 | Peer range |
How does Pro1 CT855iSH rank across federal compliance and ENERGY STAR cohorts?
Pro1 CT855iSH ranks #46 of 116 (tied with 3 others at 0.47 W, top 42.2%, lower standby draw than 57.8% of certified thermostats) for Network Standby (-0.13 W vs 0.60 W category median) across 1 certified SKU combination. Supports Wi-Fi with +/-1.36 F static accuracy and 0.47 W network standby. Zero CPSC residential HVAC recall filings match Pro1 in ThermalSpec's current SaferProducts feed.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Network Standby) | #46 of 116 (Top 42.2%, 4 tied) | -0.13 W vs 0.60 W category median |
| Static Temp Accuracy | +/-1.36 F | +0.85 F vs 0.51 F median |
| Idle-to-Standby Timeout | 16.1 min | ENERGY STAR CT Spec |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Low Network Standby Power (<= 1.0 W) | LOW DRAW | Measured 0.47 W average network standby vs 0.6 W category median |
| Thermostat Static Accuracy (<= 0.5 F) | STANDARD | Lab static accuracy +/-1.36 F vs 0.51 F category median |
| 24VAC Common Wire & Control Interfaces | CONNECTED | Methods: Wi-Fi; check O (Carrier/Trane) vs B (Rheem/Ruud) reversing valve |
How much annual energy and operating cost does Pro1 CT855iSH require?
Annual cost outputs combine Pro1 CT855iSH's 0.47 W rating and EIA national tariffs across single-family runtime hours.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Continuous Standby Electricity (8,760 hrs) | 4.12 kWh/yr | $0.67/yr |
| State Standby Cost Spread | $0.52 (NV) | to $1.94/yr (HI) |
| Static Control Band (+/-F) | +/-1.36 F | Lower band tightens setpoint deadband cycling |
Cooling mode energizes O terminal on Carrier, Trane, Lennox, Goodman, and Bosch; Rheem and Ruud energize B on heating.
Which AHRI certified SKU combinations belong to Pro1 CT855iSH?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Pro1 CT855iSH (PD ID 2383693).
| CT855iSH | Matched AHRI Coil | — |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Pro1 CT855iSH, review 2 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Pro1 CT855iSH: headline Network Standby reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Pro1 CT855iSH exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Pro1 CT855iSH fit | Single-family replacement needing documented ENERGY STAR PD ID 2383693 with matching indoor air handler. |
| Skip Pro1 CT855iSH if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable smart thermostat models deliver similar efficiency?
Compare Pro1 CT855iSH against Vive TP-S-855iCRH and closely matched smart thermostat units sharing similar Network Standby output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Pro1 CT855iSH compare with peer Smart Thermostat units?
Pro1 CT855iSH holds #46 of 116 (Top 42.2%, 4 tied) out of 116 verified smart thermostat models (-0.13 W vs 0.60 W category median), spanning 1 certified SKU up to 0.47 W standby. Closest same-cohort alternatives include Vive TP-S-855iCRH.
Where is Pro1 CT855iSH compliant for 2026 US installation?
Pro1 CT855iSH: ENERGY STAR certified connected thermostat evaluated for static temperature accuracy and network standby watts. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Pro1 CT855iSH model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Pro1 CT855iSH runs 4.12 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does Pro1 CT855iSH cover?
Pro1 CT855iSH covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Pro1 CT855iSH handle extreme weather or cold snaps?
Pro1 CT855iSH delivers steady fuel combustion independent of outdoor air temperature.
What refrigerant class and 2026 tax credit rules govern Pro1 CT855iSH?
Pro1 CT855iSH specifies sealed combustion compliance (PD ID 2383693); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in Pro1 CT855iSH reach 0.47 W standby?
Peak 0.47 W standby represents the top tested AHRI pairing for Pro1 CT855iSH (PD ID 2383693); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Pro1 CT855iSH?
Pro1 CT855iSH requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Vive TP-S-855iCRH.
Sources
Verified numerical figures and rules trace to the 3 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Smart Thermostats Dataset (7p2p-wkbf) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.