Skip to main content
Smart Thermostat · Lennox · 1 ENERGY STAR Combinations

Lennox 30L27 — Smart Thermostat Specifications

Lennox 30L27 (Smart Thermostat, PD ID 4517802) holds 1 ENERGY STAR certified SKU rated at 0.68W Standby — #61 of 116 (Lower than 47.4% of peers), +0.08 W. ENERGY STAR certified connected thermostat evaluated for static temperature accuracy and network standby watts. Lennox 30L27 — Smart Thermostat Specifications benchmarks residential systems using Cohort Rank set at #61/116 and Verified Combos set at 1 SKU.

Cohort Rank
#61/116
Verified Combos
1 SKU
Sample PD ID
4517802
Federal AC Minimum
13.4 - 14.3 SEER2
Smart Thermostat Efficiency Spread across 116 certified series (0.0 to 2.6 W)
Lennox 30L27 Smart Thermostat Efficiency Spread Distribution Distribution of 116 certified series from 0.0 to 2.6 W. Lennox 30L27 sits at 0.68 W; typical midpoint is 0.6 W. 25 0.0 34 0.3 11 0.6 8 0.9 12 1.2 12 1.5 6 1.7 4 2.0 4 2.3 Median 0.6 W This model: 0.68 W (Lower standby draw is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
0.0 - 0.3 W25Peer range
0.3 - 0.6 W34Peer range
0.6 - 0.9 W11This series
0.9 - 1.2 W8Peer range
1.2 - 1.5 W12Peer range
1.5 - 1.7 W12Peer range
1.7 - 2.0 W6Peer range
2.0 - 2.3 W4Peer range
2.3 - 2.6 W4Peer range
Color-coded low-voltage thermostat wires terminated into brass wall plate terminals
Lennox 30L27 residential equipment inspection. ThermalSpec Editorial Photography

How does Lennox 30L27 rank across federal compliance and ENERGY STAR cohorts?

Lennox 30L27 ranks #61 of 116 (lower standby draw than 47.4% of certified thermostats) for Network Standby (+0.08 W vs 0.60 W category median) across 1 certified SKU combination. Supports Bluetooth, Wi-Fi with +/-0.46 F static accuracy and 0.68 W network standby. 1 CPSC residential HVAC recall filing(s) involve Lennox product lines — confirm serial range at /recalls/.

Lennox 30L27 Cohort Metrics vs. Smart Thermostat Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Network Standby) #61 of 116 (Lower than 47.4% of peers) +0.08 W vs 0.60 W category median
Static Temp Accuracy +/-0.46 F -0.05 F vs 0.51 F median
Idle-to-Standby Timeout 30.0 min ENERGY STAR CT Spec
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Low Network Standby Power (<= 1.0 W) LOW DRAW Measured 0.68 W average network standby vs 0.6 W category median
Thermostat Static Accuracy (<= 0.5 F) HIGH PRECISION Lab static accuracy +/-0.46 F vs 0.51 F category median
24VAC Common Wire & Control Interfaces CONNECTED Methods: Bluetooth, Wi-Fi; check O (Carrier/Trane) vs B (Rheem/Ruud) reversing valve

How much annual energy and operating cost does Lennox 30L27 require?

Annual cost outputs combine Lennox 30L27's 0.68 W rating and EIA national tariffs across single-family runtime hours.

Standby_kWh = (0.68 W * 8,760 hrs) / 1,000 | Standby_USD = Standby_kWh * $0.1633/kWh

Continuous 24/7/365 network standby draw priced at US 51-state median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
Continuous Standby Electricity (8,760 hrs)5.96 kWh/yr$0.97/yr
State Standby Cost Spread$0.76 (NV)to $2.81/yr (HI)
Static Control Band (+/-F)+/-0.46 FLower band tightens setpoint deadband cycling
Split Heat Pump Reversing Valve & 24VAC O/B Control Flow
Split Heat Pump Refrigerant Cycle and 24VAC Reversing Valve Path Technical schematic connecting Outdoor Compressor, 4-Way Reversing Valve (O vs B 24VAC coil), TXV Expansion Valve, and Indoor Evaporator A-Coil. Outdoor Condenser COMP 14.3 SEER2 Min 4-Way Valve O = Cool (Carrier/Trane) B = Heat (Rheem/Ruud) TXV / EEV Metering Indoor A-Coil 7.5 HSPF2 Min 24VAC Reversing Valve & Refrigerant Path (Federal Standard) Vapor Suction Line (5/8" to 1-1/8" insulated) <-> Liquid Line (3/8" OD)

Cooling mode energizes O terminal on Carrier, Trane, Lennox, Goodman, and Bosch; Rheem and Ruud energize B on heating.

Which AHRI certified SKU combinations belong to Lennox 30L27?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Lennox 30L27 (PD ID 4517802).

30L27 Matched AHRI Coil —

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Lennox 30L27, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Lennox 30L27: headline Network Standby reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for Lennox 30L27 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal Lennox 30L27 fitSingle-family replacement needing documented ENERGY STAR PD ID 4517802 with matching indoor air handler.
Skip Lennox 30L27 ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable smart thermostat models deliver similar efficiency?

Compare Lennox 30L27 against First Alert TH2********* and closely matched smart thermostat units sharing similar Network Standby output and BTU tonnage.

First Alert TH2*********

0.61 W · +/-0.45 F · Wi-Fi

Aprilaire S86WMUPR

0.6 W · +/-0.65 F · Wi-Fi

Cielo Breez CT101WA

0.6 W · +/-0.8 F · Bluetooth, Wi-Fi

MegaLight SWFTC28TFTLCD

0.8 W · +/-0.92 F · Wi-Fi

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Lennox 30L27 compare with peer Smart Thermostat units?

Lennox 30L27 holds #61 of 116 (Lower than 47.4% of peers) out of 116 verified smart thermostat models (+0.08 W vs 0.60 W category median), spanning 1 certified SKU up to 0.68 W standby. Closest same-cohort alternatives include First Alert TH2*********.

DOE Regions

Where is Lennox 30L27 compliant for 2026 US installation?

Lennox 30L27: ENERGY STAR certified connected thermostat evaluated for static temperature accuracy and network standby watts. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Lennox 30L27 model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Lennox 30L27 runs 5.96 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Lennox 30L27 cover?

Lennox 30L27 covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Lennox 30L27 handle extreme weather or cold snaps?

Lennox 30L27 delivers steady fuel combustion independent of outdoor air temperature.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Lennox 30L27?

Lennox 30L27 specifies sealed combustion compliance (PD ID 4517802); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in Lennox 30L27 reach 0.68 W standby?

Peak 0.68 W standby represents the top tested AHRI pairing for Lennox 30L27 (PD ID 4517802); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Lennox 30L27?

Lennox 30L27 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include First Alert TH2*********.

Sources

Verified numerical figures and rules trace to the 3 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Smart Thermostats Dataset (7p2p-wkbf) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
  3. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros