Skip to main content
Smart Thermostat · First Alert · 1 ENERGY STAR Combinations

First Alert THX1200** — Smart Thermostat Specifications

First Alert THX1200** (Smart Thermostat, PD ID 4429195) holds 1 ENERGY STAR certified SKU rated at 2.59W Standby — #113 of 116 (4 tied at floor), +1.99 W. ENERGY STAR certified connected thermostat evaluated for static temperature accuracy and network standby watts. First Alert THX1200** — Smart Thermostat Specifications benchmarks residential systems using Cohort Rank set at #113/116 and Verified Combos set at 1 SKU.

Cohort Rank
#113/116
Verified Combos
1 SKU
Sample PD ID
4429195
Federal AC Minimum
13.4 - 14.3 SEER2
Smart Thermostat Efficiency Spread across 116 certified series (0.0 to 2.6 W)
First Alert THX1200** Smart Thermostat Efficiency Spread Distribution Distribution of 116 certified series from 0.0 to 2.6 W. First Alert THX1200** sits at 2.59 W; typical midpoint is 0.6 W. 25 0.0 34 0.3 11 0.6 8 0.9 12 1.2 12 1.5 6 1.7 4 2.0 4 2.3 Median 0.6 W This model: 2.59 W (Lower standby draw is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
0.0 - 0.3 W25Peer range
0.3 - 0.6 W34Peer range
0.6 - 0.9 W11Peer range
0.9 - 1.2 W8Peer range
1.2 - 1.5 W12Peer range
1.5 - 1.7 W12Peer range
1.7 - 2.0 W6Peer range
2.0 - 2.3 W4Peer range
2.3 - 2.6 W4This series
Color-coded low-voltage thermostat wires terminated into brass wall plate terminals
First Alert THX1200** residential equipment inspection. ThermalSpec Editorial Photography

How does First Alert THX1200** rank across federal compliance and ENERGY STAR cohorts?

First Alert THX1200** ties with 3 peers at 2.59 W (the cohort floor across 116 certified thermostats) for Network Standby (+1.99 W vs 0.60 W category median) across 1 certified SKU combination. Supports Bluetooth, Other, Wi-Fi with +/-0.63 F static accuracy and 2.59 W network standby. Zero CPSC residential HVAC recall filings match First Alert in ThermalSpec's current SaferProducts feed.

First Alert THX1200** Cohort Metrics vs. Smart Thermostat Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Network Standby) #113 of 116 (4 tied at floor) +1.99 W vs 0.60 W category median
Static Temp Accuracy +/-0.63 F +0.12 F vs 0.51 F median
Idle-to-Standby Timeout 47.0 min ENERGY STAR CT Spec
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Low Network Standby Power (<= 1.0 W) STANDARD DRAW Measured 2.59 W average network standby vs 0.6 W category median
Thermostat Static Accuracy (<= 0.5 F) STANDARD Lab static accuracy +/-0.63 F vs 0.51 F category median
24VAC Common Wire & Control Interfaces CONNECTED Methods: Bluetooth, Other, Wi-Fi; check O (Carrier/Trane) vs B (Rheem/Ruud) reversing valve

How much annual energy and operating cost does First Alert THX1200** require?

Modeled utility figures for First Alert THX1200** (First Alert) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Network Standby ratings.

Standby_kWh = (2.59 W * 8,760 hrs) / 1,000 | Standby_USD = Standby_kWh * $0.1633/kWh

Continuous 24/7/365 network standby draw priced at US 51-state median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
Continuous Standby Electricity (8,760 hrs)22.69 kWh/yr$3.71/yr
State Standby Cost Spread$2.89 (NV)to $10.71/yr (HI)
Static Control Band (+/-F)+/-0.63 FLower band tightens setpoint deadband cycling
Split Heat Pump Reversing Valve & 24VAC O/B Control Flow
Split Heat Pump Refrigerant Cycle and 24VAC Reversing Valve Path Technical schematic connecting Outdoor Compressor, 4-Way Reversing Valve (O vs B 24VAC coil), TXV Expansion Valve, and Indoor Evaporator A-Coil. Outdoor Condenser COMP 14.3 SEER2 Min 4-Way Valve O = Cool (Carrier/Trane) B = Heat (Rheem/Ruud) TXV / EEV Metering Indoor A-Coil 7.5 HSPF2 Min 24VAC Reversing Valve & Refrigerant Path (Federal Standard) Vapor Suction Line (5/8" to 1-1/8" insulated) <-> Liquid Line (3/8" OD)

Cooling mode energizes O terminal on Carrier, Trane, Lennox, Goodman, and Bosch; Rheem and Ruud energize B on heating.

Which AHRI certified SKU combinations belong to First Alert THX1200**?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for First Alert THX1200** (PD ID 4429195).

THX1200** Matched AHRI Coil —

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on First Alert THX1200**, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across First Alert THX1200**: headline Network Standby reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for First Alert THX1200** exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal First Alert THX1200** fitSingle-family replacement needing documented ENERGY STAR PD ID 4429195 with matching indoor air handler.
Skip First Alert THX1200** ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable smart thermostat models deliver similar efficiency?

Compare First Alert THX1200** against Resideo C4-SMART-THERM and closely matched smart thermostat units sharing similar Network Standby output and BTU tonnage.

Resideo C4-SMART-THERM

2.59 W · +/-0.63 F · Bluetooth, Other, Wi-Fi

First Alert THX1100**

2.59 W · +/-0.63 F · Bluetooth, Other, Wi-Fi

First Alert X8V*****

2.59 W · +/-0.63 F · Bluetooth, Other, Wi-Fi

Alarm.com ADC-T40K-HQ-AT

1.99 W · +/-0.19 F · Bluetooth, Other, Wi-Fi, Z-Wave

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does First Alert THX1200** compare with peer Smart Thermostat units?

First Alert THX1200** holds #113 of 116 (4 tied at floor) out of 116 verified smart thermostat models (+1.99 W vs 0.60 W category median), spanning 1 certified SKU up to 2.59 W standby. Closest same-cohort alternatives include Resideo C4-SMART-THERM.

DOE Regions

Where is First Alert THX1200** compliant for 2026 US installation?

First Alert THX1200**: ENERGY STAR certified connected thermostat evaluated for static temperature accuracy and network standby watts. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does First Alert THX1200** model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, First Alert THX1200** runs 22.69 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does First Alert THX1200** cover?

First Alert THX1200** covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does First Alert THX1200** handle extreme weather or cold snaps?

First Alert THX1200** delivers steady fuel combustion independent of outdoor air temperature.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern First Alert THX1200**?

First Alert THX1200** specifies sealed combustion compliance (PD ID 4429195); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in First Alert THX1200** reach 2.59 W standby?

Peak 2.59 W standby represents the top tested AHRI pairing for First Alert THX1200** (PD ID 4429195); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to First Alert THX1200**?

First Alert THX1200** requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Resideo C4-SMART-THERM.

Sources

Verified numerical figures and rules trace to the 3 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Smart Thermostats Dataset (7p2p-wkbf) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
  3. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros