Skip to main content
Smart Thermostat · American Standard · 1 ENERGY STAR Combinations

American Standard ACONT824AS52DB — Smart Thermostat Specifications

American Standard ACONT824AS52DB (Smart Thermostat, PD ID 2337840) holds 1 ENERGY STAR certified SKU rated at 1.9W Standby — #105 of 116 (2 tied, lower than 8.6% of peers), +1.30 W. ENERGY STAR certified connected thermostat evaluated for static temperature accuracy and network standby watts. American Standard ACONT824AS52DB — Smart Thermostat Specifications benchmarks residential systems using Cohort Rank set at #105/116 and Verified Combos set at 1 SKU.

Cohort Rank
#105/116
Verified Combos
1 SKU
Sample PD ID
2337840
Federal AC Minimum
13.4 - 14.3 SEER2
Smart Thermostat Efficiency Spread across 116 certified series (0.0 to 2.6 W)
American Standard ACONT824AS52DB Smart Thermostat Efficiency Spread Distribution Distribution of 116 certified series from 0.0 to 2.6 W. American Standard ACONT824AS52DB sits at 1.9 W; typical midpoint is 0.6 W. 25 0.0 34 0.3 11 0.6 8 0.9 12 1.2 12 1.5 6 1.7 4 2.0 4 2.3 Median 0.6 W This model: 1.9 W (Lower standby draw is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
0.0 - 0.3 W25Peer range
0.3 - 0.6 W34Peer range
0.6 - 0.9 W11Peer range
0.9 - 1.2 W8Peer range
1.2 - 1.5 W12Peer range
1.5 - 1.7 W12Peer range
1.7 - 2.0 W6This series
2.0 - 2.3 W4Peer range
2.3 - 2.6 W4Peer range
Color-coded low-voltage thermostat wires terminated into brass wall plate terminals
American Standard ACONT824AS52DB residential equipment inspection. ThermalSpec Editorial Photography

How does American Standard ACONT824AS52DB rank across federal compliance and ENERGY STAR cohorts?

American Standard ACONT824AS52DB ranks #105 of 116 (tied with 1 other at 1.90 W, lower standby draw than 8.6% of certified thermostats) for Network Standby (+1.30 W vs 0.60 W category median) across 1 certified SKU combination. Supports Wi-Fi, Z-Wave with +/-0.73 F static accuracy and 1.9 W network standby. Zero CPSC residential HVAC recall filings match American Standard in ThermalSpec's current SaferProducts feed.

American Standard ACONT824AS52DB Cohort Metrics vs. Smart Thermostat Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Network Standby) #105 of 116 (2 tied, lower than 8.6% of peers) +1.30 W vs 0.60 W category median
Static Temp Accuracy +/-0.73 F +0.22 F vs 0.51 F median
Idle-to-Standby Timeout 30.0 min ENERGY STAR CT Spec
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Low Network Standby Power (<= 1.0 W) STANDARD DRAW Measured 1.9 W average network standby vs 0.6 W category median
Thermostat Static Accuracy (<= 0.5 F) STANDARD Lab static accuracy +/-0.73 F vs 0.51 F category median
24VAC Common Wire & Control Interfaces CONNECTED Methods: Wi-Fi, Z-Wave; check O (Carrier/Trane) vs B (Rheem/Ruud) reversing valve

How much annual energy and operating cost does American Standard ACONT824AS52DB require?

Annual cost outputs combine American Standard ACONT824AS52DB's 1.9 W rating and EIA national tariffs across single-family runtime hours.

Standby_kWh = (1.9 W * 8,760 hrs) / 1,000 | Standby_USD = Standby_kWh * $0.1633/kWh

Continuous 24/7/365 network standby draw priced at US 51-state median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
Continuous Standby Electricity (8,760 hrs)16.64 kWh/yr$2.72/yr
State Standby Cost Spread$2.12 (NV)to $7.85/yr (HI)
Static Control Band (+/-F)+/-0.73 FLower band tightens setpoint deadband cycling
Split Heat Pump Reversing Valve & 24VAC O/B Control Flow
Split Heat Pump Refrigerant Cycle and 24VAC Reversing Valve Path Technical schematic connecting Outdoor Compressor, 4-Way Reversing Valve (O vs B 24VAC coil), TXV Expansion Valve, and Indoor Evaporator A-Coil. Outdoor Condenser COMP 14.3 SEER2 Min 4-Way Valve O = Cool (Carrier/Trane) B = Heat (Rheem/Ruud) TXV / EEV Metering Indoor A-Coil 7.5 HSPF2 Min 24VAC Reversing Valve & Refrigerant Path (Federal Standard) Vapor Suction Line (5/8" to 1-1/8" insulated) <-> Liquid Line (3/8" OD)

Cooling mode energizes O terminal on Carrier, Trane, Lennox, Goodman, and Bosch; Rheem and Ruud energize B on heating.

Which AHRI certified SKU combinations belong to American Standard ACONT824AS52DB?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for American Standard ACONT824AS52DB (PD ID 2337840).

ACONT824AS52DB Matched AHRI Coil —

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on American Standard ACONT824AS52DB, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across American Standard ACONT824AS52DB: headline Network Standby reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for American Standard ACONT824AS52DB exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal American Standard ACONT824AS52DB fitSingle-family replacement needing documented ENERGY STAR PD ID 2337840 with matching indoor air handler.
Skip American Standard ACONT824AS52DB ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable smart thermostat models deliver similar efficiency?

Compare American Standard ACONT824AS52DB against Trane TCONT824AS52DB and closely matched smart thermostat units sharing similar Network Standby output and BTU tonnage.

Trane TCONT824AS52DB

1.9 W · +/-0.73 F · Wi-Fi, Z-Wave

NUVE Smart Thermostat SAMO

1.89 W · +/-1.69 F · Wi-Fi

Ecobee EB-STATE6*

1.83 W · +/-0.53 F · Bluetooth, Other, Wi-Fi

Alarm.com ADC-T40K-HQ-AT

1.99 W · +/-0.19 F · Bluetooth, Other, Wi-Fi, Z-Wave

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does American Standard ACONT824AS52DB compare with peer Smart Thermostat units?

American Standard ACONT824AS52DB holds #105 of 116 (2 tied, lower than 8.6% of peers) out of 116 verified smart thermostat models (+1.30 W vs 0.60 W category median), spanning 1 certified SKU up to 1.9 W standby. Closest same-cohort alternatives include Trane TCONT824AS52DB.

DOE Regions

Where is American Standard ACONT824AS52DB compliant for 2026 US installation?

American Standard ACONT824AS52DB: ENERGY STAR certified connected thermostat evaluated for static temperature accuracy and network standby watts. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does American Standard ACONT824AS52DB model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, American Standard ACONT824AS52DB runs 16.64 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does American Standard ACONT824AS52DB cover?

American Standard ACONT824AS52DB covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does American Standard ACONT824AS52DB handle extreme weather or cold snaps?

American Standard ACONT824AS52DB delivers steady fuel combustion independent of outdoor air temperature.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern American Standard ACONT824AS52DB?

American Standard ACONT824AS52DB specifies sealed combustion compliance (PD ID 2337840); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in American Standard ACONT824AS52DB reach 1.9 W standby?

Peak 1.9 W standby represents the top tested AHRI pairing for American Standard ACONT824AS52DB (PD ID 2337840); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to American Standard ACONT824AS52DB?

American Standard ACONT824AS52DB requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Trane TCONT824AS52DB.

Sources

Verified numerical figures and rules trace to the 3 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Smart Thermostats Dataset (7p2p-wkbf) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
  3. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.