Skip to main content
Room Air Conditioner · Whirlpool · 1 ENERGY STAR Combinations

Whirlpool WHAW050EX — Room Air Conditioner Specifications

Whirlpool WHAW050EX (Room Air Conditioner, PD ID 4713634) holds 1 ENERGY STAR certified SKU rated at 13.1 CEER — #575 of 589 (Beats 2.4% of peers), -1.90 CEER. ENERGY STAR certified room air conditioner (13.1 CEER). Whirlpool WHAW050EX — Room Air Conditioner Specifications benchmarks residential systems using Cooling CEER set at 13.1 CEER and Cohort Rank set at #575/589.

Cooling CEER
13.1 CEER
Cohort Rank
#575/589
Verified Combos
1 SKU
Sample PD ID
4713634
Room Air Conditioner Efficiency Spread across 589 certified series (12.0 to 17.6 CEER)
Whirlpool WHAW050EX Room Air Conditioner Efficiency Spread Distribution Distribution of 589 certified series from 12.0 to 17.6 CEER. Whirlpool WHAW050EX sits at 13.1 CEER; typical midpoint is 15.0 CEER. 5 12.0 14 12.6 78 13.2 96 13.9 233 14.5 13 15.1 140 15.7 2 16.4 8 17.0 Median 15.0 CEER This model: 13.1 CEER (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
12.0 - 12.6 CEER5Peer range
12.6 - 13.2 CEER14This series
13.2 - 13.9 CEER78Peer range
13.9 - 14.5 CEER96Peer range
14.5 - 15.1 CEER233Peer range
15.1 - 15.7 CEER13Peer range
15.7 - 16.4 CEER140Peer range
16.4 - 17.0 CEER2Peer range
17.0 - 17.6 CEER8Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
Whirlpool WHAW050EX residential equipment inspection. ThermalSpec Editorial Photography

How does Whirlpool WHAW050EX rank across federal compliance and ENERGY STAR cohorts?

Whirlpool WHAW050EX ranks #575 of 589 (more efficient than 2.4% of certified series) for Max CEER (-1.90 CEER vs 15.0 CEER category median) across 1 certified SKU combination. Straddles Window 115V chassis (0.4 nominal Tons at 5,000 BTU/h) drawing 286.3 kWh/yr (19% less energy than federal baseline). Zero CPSC residential HVAC recall filings match Whirlpool in ThermalSpec's current SaferProducts feed.

Whirlpool WHAW050EX Cohort Metrics vs. Room Air Conditioner Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max CEER) #575 of 589 (Beats 2.4% of peers) -1.90 CEER vs 15.0 CEER category median
Energy Margin vs Federal Std 19% less kWh -20.0% vs 39% median
DOE Annual Test Energy 286.3 kWh/yr -245.6 kWh vs 531.9 kWh median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
2026 Cleaner Refrigerant Rule COMPLIANT A2L Uses R-32 (cleaner low-warming refrigerant standard)
Electrical Supply Circuit 115V Standard 15A/20A 115V household receptacle
Variable-Speed Inverter Compressor INVERTER Variable-Speed

How much annual energy and operating cost does Whirlpool WHAW050EX require?

Modeled utility figures for Whirlpool WHAW050EX (Whirlpool) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max CEER ratings.

Annual_USD = 286.3 kWh/yr (EPA 750-hr test) * $/kWh | Fed_Baseline_kWh = 286.3 / (1 - 0.19)

EPA ENERGY STAR annual kWh test basis at US median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
EPA Rated Annual Energy Consumption286.3 kWh/yr$46.75/yr at US median
State Operating Cost Spread$36.42 (NV)to $135.08/yr (HI)
Energy Saved vs US Federal Baseline67.2 kWh/yr (19%)$10.97/yr saved
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to Whirlpool WHAW050EX?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Whirlpool WHAW050EX (PD ID 4713634).

WHAW050EX Matched AHRI Coil 5,000 BTU/h

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Whirlpool WHAW050EX, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Whirlpool WHAW050EX: headline Max CEER reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for Whirlpool WHAW050EX exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal Whirlpool WHAW050EX fitSingle-family replacement needing documented ENERGY STAR PD ID 4713634 with matching indoor air handler.
Skip Whirlpool WHAW050EX ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable room air conditioner models deliver similar efficiency?

Compare Whirlpool WHAW050EX against GE Appliances AWGP08W**# and closely matched room air conditioner units sharing similar Max CEER output and BTU tonnage.

GE Appliances AWGP08W**#

13.2 CEER · 35% less kWh · 8,000 BTU/h

Friedrich WCVT10B10A

13.0 CEER · 37% less kWh · 11,000 BTU/h

GE Appliances AWGP12W**#

13.2 CEER · 35% less kWh · 11,000 BTU/h

Friedrich WCVT10B30A

13.0 CEER · 37% less kWh · 11,100 BTU/h

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Whirlpool WHAW050EX compare with peer Room Air Conditioner units?

Whirlpool WHAW050EX holds #575 of 589 (Beats 2.4% of peers) out of 589 verified room air conditioner models (-1.90 CEER vs 15.0 CEER category median), spanning 1 certified SKU up to 13.1 CEER. Closest same-cohort alternatives include GE Appliances AWGP08W**#.

DOE Regions

Where is Whirlpool WHAW050EX compliant for 2026 US installation?

Whirlpool WHAW050EX: ENERGY STAR certified room air conditioner (13.1 CEER). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Whirlpool WHAW050EX model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Whirlpool WHAW050EX runs 286.3 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Whirlpool WHAW050EX cover?

Whirlpool WHAW050EX covers 5,000-5,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Whirlpool WHAW050EX handle extreme weather or cold snaps?

Whirlpool WHAW050EX is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Whirlpool WHAW050EX?

Whirlpool WHAW050EX specifies R-32 compliance (PD ID 4713634); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in Whirlpool WHAW050EX reach 13.1 CEER?

Peak 13.1 CEER represents the top tested AHRI pairing for Whirlpool WHAW050EX (PD ID 4713634); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Whirlpool WHAW050EX?

Whirlpool WHAW050EX requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include GE Appliances AWGP08W**#.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 8 pages.

Comparable HVAC Climate & Cost Metros