Sea Breeze WA324ZREB (Room Air Conditioner, PD ID 3943245) holds 1 ENERGY STAR certified SKU rated at 13.3 CEER — #554 of 589 (17 tied, beats 3.2% of peers), -1.70 CEER. ENERGY STAR certified room air conditioner (13.3 CEER). Sea Breeze WA324ZREB — Room Air Conditioner Specifications benchmarks residential systems using Cooling CEER set at 13.3 CEER and Cohort Rank set at #554/589.

Cooling CEER
13.3 CEER
Cohort Rank
#554/589
Verified Combos
1 SKU
Sample PD ID
3943245
Room Air Conditioner Efficiency Spread across 589 certified series (12.0 to 17.6 CEER)
Sea Breeze WA324ZREB Room Air Conditioner Efficiency Spread Distribution Distribution of 589 certified series from 12.0 to 17.6 CEER. Sea Breeze WA324ZREB sits at 13.3 CEER; typical midpoint is 15.0 CEER. 5 12.0 14 12.6 78 13.2 96 13.9 233 14.5 13 15.1 140 15.7 2 16.4 8 17.0 Median 15.0 CEER This model: 13.3 CEER (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
12.0 - 12.6 CEER5Peer range
12.6 - 13.2 CEER14Peer range
13.2 - 13.9 CEER78This series
13.9 - 14.5 CEER96Peer range
14.5 - 15.1 CEER233Peer range
15.1 - 15.7 CEER13Peer range
15.7 - 16.4 CEER140Peer range
16.4 - 17.0 CEER2Peer range
17.0 - 17.6 CEER8Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
Sea Breeze WA324ZREB residential equipment inspection. ThermalSpec Editorial Photography

How does Sea Breeze WA324ZREB rank across federal compliance and ENERGY STAR cohorts?

Sea Breeze WA324ZREB ranks #554 of 589 (tied with 16 others at 13.3 CEER, more efficient than 3.2% of certified series) for Max CEER (-1.70 CEER vs 15.0 CEER category median) across 1 certified SKU combination. Does Not Straddle Window or Windowsill 230V chassis (2.0 nominal Tons at 24,000 BTU/h) drawing 1353.4 kWh/yr (41% less energy than federal baseline).

Sea Breeze WA324ZREB Cohort Metrics vs. Room Air Conditioner Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max CEER) #554 of 589 (17 tied, beats 3.2% of peers) -1.70 CEER vs 15.0 CEER category median
Energy Margin vs Federal Std 41% less kWh +2.0% vs 39% median
DOE Annual Test Energy 1,353.4 kWh/yr +821.5 kWh vs 531.9 kWh median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
2026 Cleaner Refrigerant Rule COMPLIANT A2L Uses R-32 (cleaner low-warming refrigerant standard)
Electrical Supply Circuit 230V Requires dedicated 208/230V NEMA 6-15/6-20 receptacle
Variable-Speed Inverter Compressor INVERTER Variable-Speed

How much annual energy and operating cost does Sea Breeze WA324ZREB require?

Annual cost outputs combine Sea Breeze WA324ZREB's 13.3 CEER rating and EIA national tariffs across single-family runtime hours.

Annual_USD = 1353.4 kWh/yr (EPA 750-hr test) * $/kWh | Fed_Baseline_kWh = 1353.4 / (1 - 0.41)

EPA ENERGY STAR annual kWh test basis at US median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
EPA Rated Annual Energy Consumption1353.4 kWh/yr$221.01/yr at US median
State Operating Cost Spread$172.15 (NV)to $638.53/yr (HI)
Energy Saved vs US Federal Baseline940.5 kWh/yr (41%)$153.58/yr saved
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to Sea Breeze WA324ZREB?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Sea Breeze WA324ZREB (PD ID 3943245).

WA324ZREB Matched AHRI Coil 24,000 BTU/h

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Sea Breeze WA324ZREB, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Sea Breeze WA324ZREB: headline Max CEER reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for Sea Breeze WA324ZREB exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal Sea Breeze WA324ZREB fitSingle-family replacement needing documented ENERGY STAR PD ID 3943245 with matching indoor air handler.
Skip Sea Breeze WA324ZREB ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable room air conditioner models deliver similar efficiency?

Compare Sea Breeze WA324ZREB against Comfort Aire RADS-253R03 and closely matched room air conditioner units sharing similar Max CEER output and BTU tonnage.

Comfort Aire RADS-253R03

13.3 CEER · 41% less kWh · 24,000 BTU/h

Frigidaire FHWW245WE2

13.3 CEER · 41% less kWh · 24,000 BTU/h

Keplerx KBRC24RSVE2

13.3 CEER · 41% less kWh · 24,000 BTU/h

Keystone KSTAW242WA

13.3 CEER · 41% less kWh · 24,000 BTU/h

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Sea Breeze WA324ZREB compare with peer Room Air Conditioner units?

Sea Breeze WA324ZREB holds #554 of 589 (17 tied, beats 3.2% of peers) out of 589 verified room air conditioner models (-1.70 CEER vs 15.0 CEER category median), spanning 1 certified SKU up to 13.3 CEER. Closest same-cohort alternatives include Comfort Aire RADS-253R03.

DOE Regions

Where is Sea Breeze WA324ZREB compliant for 2026 US installation?

Sea Breeze WA324ZREB: ENERGY STAR certified room air conditioner (13.3 CEER). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Sea Breeze WA324ZREB model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Sea Breeze WA324ZREB runs 1353.4 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Sea Breeze WA324ZREB cover?

Sea Breeze WA324ZREB covers 24,000-24,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Sea Breeze WA324ZREB handle extreme weather or cold snaps?

Sea Breeze WA324ZREB is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Sea Breeze WA324ZREB?

Sea Breeze WA324ZREB specifies R-32 compliance (PD ID 3943245); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in Sea Breeze WA324ZREB reach 13.3 CEER?

Peak 13.3 CEER represents the top tested AHRI pairing for Sea Breeze WA324ZREB (PD ID 3943245); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Sea Breeze WA324ZREB?

Sea Breeze WA324ZREB requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Comfort Aire RADS-253R03.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros