Midea MW10MSWBA6RCM — Room Air Conditioner Specifications
Midea MW10MSWBA6RCM (Room Air Conditioner, PD ID 2620522) holds 1 ENERGY STAR certified SKU rated at 15.0 CEER — #185 of 589 (195 tied at median), Equal to 15.0 CEER category median. ENERGY STAR certified room air conditioner (15.0 CEER). Midea MW10MSWBA6RCM — Room Air Conditioner Specifications benchmarks residential systems using Cooling CEER set at 15.0 CEER and Cohort Rank set at #185/589.
- Cooling CEER
- 15.0 CEER
- Cohort Rank
- #185/589
- Verified Combos
- 1 SKU
- Sample PD ID
- 2620522
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 12.0 - 12.6 CEER | 5 | Peer range |
| 12.6 - 13.2 CEER | 14 | Peer range |
| 13.2 - 13.9 CEER | 78 | Peer range |
| 13.9 - 14.5 CEER | 96 | Peer range |
| 14.5 - 15.1 CEER | 233 | This series |
| 15.1 - 15.7 CEER | 13 | Peer range |
| 15.7 - 16.4 CEER | 140 | Peer range |
| 16.4 - 17.0 CEER | 2 | Peer range |
| 17.0 - 17.6 CEER | 8 | Peer range |
How does Midea MW10MSWBA6RCM rank across federal compliance and ENERGY STAR cohorts?
Midea MW10MSWBA6RCM ranks #185 of 589 (tied with 194 others at 15.0 CEER, more efficient than 35.7% of certified series) for Max CEER (Equal to 15.0 CEER category median) across 1 certified SKU combination. Straddles Window 115V chassis (0.8 nominal Tons at 10,000 BTU/h) drawing 500.0 kWh/yr (38% less energy than federal baseline).
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max CEER) | #185 of 589 (195 tied at median) | Equal to 15.0 CEER category median |
| Energy Margin vs Federal Std | 38% less kWh | -1.0% vs 39% median |
| DOE Annual Test Energy | 500.0 kWh/yr | -31.9 kWh vs 531.9 kWh median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| 2026 Cleaner Refrigerant Rule | COMPLIANT A2L | Uses R-32 (cleaner low-warming refrigerant standard) |
| Electrical Supply Circuit | 115V | Standard 15A/20A 115V household receptacle |
| Variable-Speed Inverter Compressor | INVERTER | Variable-Speed |
How much annual energy and operating cost does Midea MW10MSWBA6RCM require?
Annual cost outputs combine Midea MW10MSWBA6RCM's 15.0 CEER rating and EIA national tariffs across single-family runtime hours.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| EPA Rated Annual Energy Consumption | 500.0 kWh/yr | $81.65/yr at US median |
| State Operating Cost Spread | $63.60 (NV) | to $235.90/yr (HI) |
| Energy Saved vs US Federal Baseline | 306.5 kWh/yr (38%) | $50.05/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to Midea MW10MSWBA6RCM?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Midea MW10MSWBA6RCM (PD ID 2620522).
| MW10MSWBA6RCM | Matched AHRI Coil | 10,000 BTU/h |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Midea MW10MSWBA6RCM, review 2 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Midea MW10MSWBA6RCM: headline Max CEER reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Midea MW10MSWBA6RCM exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Midea MW10MSWBA6RCM fit | Single-family replacement needing documented ENERGY STAR PD ID 2620522 with matching indoor air handler. |
| Skip Midea MW10MSWBA6RCM if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable room air conditioner models deliver similar efficiency?
Compare Midea MW10MSWBA6RCM against BLACK+DECKER BD10NWES and closely matched room air conditioner units sharing similar Max CEER output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Midea MW10MSWBA6RCM compare with peer Room Air Conditioner units?
Midea MW10MSWBA6RCM holds #185 of 589 (195 tied at median) out of 589 verified room air conditioner models (Equal to 15.0 CEER category median), spanning 1 certified SKU up to 15.0 CEER. Closest same-cohort alternatives include BLACK+DECKER BD10NWES.
Where is Midea MW10MSWBA6RCM compliant for 2026 US installation?
Midea MW10MSWBA6RCM: ENERGY STAR certified room air conditioner (15.0 CEER). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Midea MW10MSWBA6RCM model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Midea MW10MSWBA6RCM runs 500.0 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does Midea MW10MSWBA6RCM cover?
Midea MW10MSWBA6RCM covers 10,000-10,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Midea MW10MSWBA6RCM handle extreme weather or cold snaps?
Midea MW10MSWBA6RCM is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.
What refrigerant class and 2026 tax credit rules govern Midea MW10MSWBA6RCM?
Midea MW10MSWBA6RCM specifies R-32 compliance (PD ID 2620522); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in Midea MW10MSWBA6RCM reach 15.0 CEER?
Peak 15.0 CEER represents the top tested AHRI pairing for Midea MW10MSWBA6RCM (PD ID 2620522); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Midea MW10MSWBA6RCM?
Midea MW10MSWBA6RCM requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include BLACK+DECKER BD10NWES.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)