Skip to main content
Room Air Conditioner · Midea · 1 ENERGY STAR Combinations

Midea MAW14V1YWT-S — Room Air Conditioner Specifications

Midea MAW14V1YWT-S (Room Air Conditioner, PD ID 4498968) holds 1 ENERGY STAR certified SKU rated at 15.0 CEER — #185 of 589 (195 tied at median), Equal to 15.0 CEER category median. ENERGY STAR certified room air conditioner (15.0 CEER). Midea MAW14V1YWT-S — Room Air Conditioner Specifications benchmarks residential systems using Cooling CEER set at 15.0 CEER and Cohort Rank set at #185/589.

Cooling CEER
15.0 CEER
Cohort Rank
#185/589
Verified Combos
1 SKU
Sample PD ID
4498968
Room Air Conditioner Efficiency Spread across 589 certified series (12.0 to 17.6 CEER)
Midea MAW14V1YWT-S Room Air Conditioner Efficiency Spread Distribution Distribution of 589 certified series from 12.0 to 17.6 CEER. Midea MAW14V1YWT-S sits at 15.0 CEER; typical midpoint is 15.0 CEER. 5 12.0 14 12.6 78 13.2 96 13.9 233 14.5 13 15.1 140 15.7 2 16.4 8 17.0 Median 15.0 CEER This model: 15.0 CEER (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
12.0 - 12.6 CEER5Peer range
12.6 - 13.2 CEER14Peer range
13.2 - 13.9 CEER78Peer range
13.9 - 14.5 CEER96Peer range
14.5 - 15.1 CEER233This series
15.1 - 15.7 CEER13Peer range
15.7 - 16.4 CEER140Peer range
16.4 - 17.0 CEER2Peer range
17.0 - 17.6 CEER8Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
Midea MAW14V1YWT-S residential equipment inspection. ThermalSpec Editorial Photography

How does Midea MAW14V1YWT-S rank across federal compliance and ENERGY STAR cohorts?

Midea MAW14V1YWT-S ranks #185 of 589 (tied with 194 others at 15.0 CEER, more efficient than 35.7% of certified series) for Max CEER (Equal to 15.0 CEER category median) across 1 certified SKU combination. Does Not Straddle Window or Windowsill 115V chassis (1.2 nominal Tons at 14,000 BTU/h) drawing 700.0 kWh/yr (40% less energy than federal baseline).

Midea MAW14V1YWT-S Cohort Metrics vs. Room Air Conditioner Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max CEER) #185 of 589 (195 tied at median) Equal to 15.0 CEER category median
Energy Margin vs Federal Std 40% less kWh +1.0% vs 39% median
DOE Annual Test Energy 700.0 kWh/yr +168.1 kWh vs 531.9 kWh median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
2026 Cleaner Refrigerant Rule COMPLIANT A2L Uses R-32 (cleaner low-warming refrigerant standard)
Electrical Supply Circuit 115V Standard 15A/20A 115V household receptacle
Variable-Speed Inverter Compressor INVERTER Variable-Speed

How much annual energy and operating cost does Midea MAW14V1YWT-S require?

Modeled utility figures for Midea MAW14V1YWT-S (Midea) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max CEER ratings.

Annual_USD = 700.0 kWh/yr (EPA 750-hr test) * $/kWh | Fed_Baseline_kWh = 700.0 / (1 - 0.40)

EPA ENERGY STAR annual kWh test basis at US median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
EPA Rated Annual Energy Consumption700.0 kWh/yr$114.31/yr at US median
State Operating Cost Spread$89.04 (NV)to $330.26/yr (HI)
Energy Saved vs US Federal Baseline466.7 kWh/yr (40%)$76.21/yr saved
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to Midea MAW14V1YWT-S?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Midea MAW14V1YWT-S (PD ID 4498968).

MAW14V1YWT-S Matched AHRI Coil 14,000 BTU/h

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Midea MAW14V1YWT-S, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Midea MAW14V1YWT-S: headline Max CEER reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for Midea MAW14V1YWT-S exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal Midea MAW14V1YWT-S fitSingle-family replacement needing documented ENERGY STAR PD ID 4498968 with matching indoor air handler.
Skip Midea MAW14V1YWT-S ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable room air conditioner models deliver similar efficiency?

Compare Midea MAW14V1YWT-S against Danby DAC140EBIBDB and closely matched room air conditioner units sharing similar Max CEER output and BTU tonnage.

Danby DAC140EBIBDB

15.0 CEER · 40% less kWh · 14,000 BTU/h

ELEMENT EHWR14BE

15.0 CEER · 40% less kWh · 14,000 BTU/h

Frigidaire FHWW145WE1

15.0 CEER · 40% less kWh · 14,000 BTU/h

GE Profile PWDV14W**#

15.0 CEER · 40% less kWh · 14,000 BTU/h

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Midea MAW14V1YWT-S compare with peer Room Air Conditioner units?

Midea MAW14V1YWT-S holds #185 of 589 (195 tied at median) out of 589 verified room air conditioner models (Equal to 15.0 CEER category median), spanning 1 certified SKU up to 15.0 CEER. Closest same-cohort alternatives include Danby DAC140EBIBDB.

DOE Regions

Where is Midea MAW14V1YWT-S compliant for 2026 US installation?

Midea MAW14V1YWT-S: ENERGY STAR certified room air conditioner (15.0 CEER). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Midea MAW14V1YWT-S model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Midea MAW14V1YWT-S runs 700.0 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Midea MAW14V1YWT-S cover?

Midea MAW14V1YWT-S covers 14,000-14,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Midea MAW14V1YWT-S handle extreme weather or cold snaps?

Midea MAW14V1YWT-S is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Midea MAW14V1YWT-S?

Midea MAW14V1YWT-S specifies R-32 compliance (PD ID 4498968); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in Midea MAW14V1YWT-S reach 15.0 CEER?

Peak 15.0 CEER represents the top tested AHRI pairing for Midea MAW14V1YWT-S (PD ID 4498968); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Midea MAW14V1YWT-S?

Midea MAW14V1YWT-S requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Danby DAC140EBIBDB.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros