Room Air Conditioner · Kuhl · 1 ENERGY STAR Combinations

Kuhl KCVL28B30B — Room Air Conditioner Specifications

Kuhl KCVL28B30B (Room Air Conditioner, PD ID 4654734) holds 1 ENERGY STAR certified SKU rated at 13.8 CEER — #493 of 589 (12 tied, beats 14.4% of peers), -1.20 CEER. ENERGY STAR certified room air conditioner (13.8 CEER). Kuhl KCVL28B30B — Room Air Conditioner Specifications benchmarks residential systems using Cooling CEER set at 13.8 CEER and Cohort Rank set at #493/589.

Cooling CEER
13.8 CEER
Cohort Rank
#493/589
Verified Combos
1 SKU
Sample PD ID
4654734
Room Air Conditioner Efficiency Spread across 589 certified series (12.0 to 17.6 CEER)
Kuhl KCVL28B30B Room Air Conditioner Efficiency Spread Distribution Distribution of 589 certified series from 12.0 to 17.6 CEER. Kuhl KCVL28B30B sits at 13.8 CEER; typical midpoint is 15.0 CEER. 5 12.0 14 12.6 78 13.2 96 13.9 233 14.5 13 15.1 140 15.7 2 16.4 8 17.0 Median 15.0 CEER This model: 13.8 CEER (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
12.0 - 12.6 CEER5Peer range
12.6 - 13.2 CEER14Peer range
13.2 - 13.9 CEER78This series
13.9 - 14.5 CEER96Peer range
14.5 - 15.1 CEER233Peer range
15.1 - 15.7 CEER13Peer range
15.7 - 16.4 CEER140Peer range
16.4 - 17.0 CEER2Peer range
17.0 - 17.6 CEER8Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
Kuhl KCVL28B30B residential equipment inspection. ThermalSpec Editorial Photography

How does Kuhl KCVL28B30B rank across federal compliance and ENERGY STAR cohorts?

Kuhl KCVL28B30B ranks #493 of 589 (tied with 11 others at 13.8 CEER, more efficient than 14.4% of certified series) for Max CEER (-1.20 CEER vs 15.0 CEER category median) across 1 certified SKU combination. Straddles Windowsill 230V chassis (2.4 nominal Tons at 28,900 BTU/h) drawing 1570.7 kWh/yr (53% less energy than federal baseline).

Kuhl KCVL28B30B Cohort Metrics vs. Room Air Conditioner Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max CEER) #493 of 589 (12 tied, beats 14.4% of peers) -1.20 CEER vs 15.0 CEER category median
Energy Margin vs Federal Std 53% less kWh +14.0% vs 39% median
DOE Annual Test Energy 1,570.7 kWh/yr +1,038.8 kWh vs 531.9 kWh median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
2026 Cleaner Refrigerant Rule COMPLIANT A2L Uses R-32 (cleaner low-warming refrigerant standard)
Electrical Supply Circuit 230V Requires dedicated 208/230V NEMA 6-15/6-20 receptacle
Variable-Speed Inverter Compressor INVERTER Variable-Speed

How much annual energy and operating cost does Kuhl KCVL28B30B require?

Annual cost outputs combine Kuhl KCVL28B30B's 13.8 CEER rating and EIA national tariffs across single-family runtime hours.

Annual_USD = 1570.7 kWh/yr (EPA 750-hr test) * $/kWh | Fed_Baseline_kWh = 1570.7 / (1 - 0.53)

EPA ENERGY STAR annual kWh test basis at US median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
EPA Rated Annual Energy Consumption1570.7 kWh/yr$256.50/yr at US median
State Operating Cost Spread$199.79 (NV)to $741.06/yr (HI)
Energy Saved vs US Federal Baseline1771.2 kWh/yr (53%)$289.24/yr saved
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to Kuhl KCVL28B30B?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Kuhl KCVL28B30B (PD ID 4654734).

KCVL28B30B Matched AHRI Coil 28,900 BTU/h

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Kuhl KCVL28B30B, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Kuhl KCVL28B30B: headline Max CEER reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for Kuhl KCVL28B30B exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal Kuhl KCVL28B30B fitSingle-family replacement needing documented ENERGY STAR PD ID 4654734 with matching indoor air handler.
Skip Kuhl KCVL28B30B ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable room air conditioner models deliver similar efficiency?

Compare Kuhl KCVL28B30B against Frigidaire FHWW245WF2 and closely matched room air conditioner units sharing similar Max CEER output and BTU tonnage.

Frigidaire FHWW245WF2

13.8 CEER · 47% less kWh · 24,000 BTU/h

GE Appliances AWHV24***#

13.8 CEER · 47% less kWh · 24,000 BTU/h

Midea MAW24RV1KWT

13.8 CEER · 47% less kWh · 24,000 BTU/h

Midea MAW24S2KWT-A

13.8 CEER · 47% less kWh · 24,000 BTU/h

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Kuhl KCVL28B30B compare with peer Room Air Conditioner units?

Kuhl KCVL28B30B holds #493 of 589 (12 tied, beats 14.4% of peers) out of 589 verified room air conditioner models (-1.20 CEER vs 15.0 CEER category median), spanning 1 certified SKU up to 13.8 CEER. Closest same-cohort alternatives include Frigidaire FHWW245WF2.

DOE Regions

Where is Kuhl KCVL28B30B compliant for 2026 US installation?

Kuhl KCVL28B30B: ENERGY STAR certified room air conditioner (13.8 CEER). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Kuhl KCVL28B30B model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Kuhl KCVL28B30B runs 1570.7 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Kuhl KCVL28B30B cover?

Kuhl KCVL28B30B covers 28,900-28,900 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Kuhl KCVL28B30B handle extreme weather or cold snaps?

Kuhl KCVL28B30B is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Kuhl KCVL28B30B?

Kuhl KCVL28B30B specifies R-32 compliance (PD ID 4654734); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in Kuhl KCVL28B30B reach 13.8 CEER?

Peak 13.8 CEER represents the top tested AHRI pairing for Kuhl KCVL28B30B (PD ID 4654734); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Kuhl KCVL28B30B?

Kuhl KCVL28B30B requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Frigidaire FHWW245WF2.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)