HOUSE KOBO KOBOGJC10BU — Room Air Conditioner Specifications

HOUSE KOBO KOBOGJC10BU (Room Air Conditioner, PD ID 4481449) holds 1 ENERGY STAR certified SKU rated at 14.7 CEER — #380 of 589 (11 tied, beats 33.8% of peers), -0.30 CEER. ENERGY STAR certified room air conditioner (14.7 CEER). HOUSE KOBO KOBOGJC10BU — Room Air Conditioner Specifications benchmarks residential systems using Cooling CEER set at 14.7 CEER and Cohort Rank set at #380/589.

Cooling CEER
14.7 CEER
Cohort Rank
#380/589
Verified Combos
1 SKU
Sample PD ID
4481449
Room Air Conditioner Efficiency Spread across 589 certified series (12.0 to 17.6 CEER)
HOUSE KOBO KOBOGJC10BU Room Air Conditioner Efficiency Spread Distribution Distribution of 589 certified series from 12.0 to 17.6 CEER. HOUSE KOBO KOBOGJC10BU sits at 14.7 CEER; typical midpoint is 15.0 CEER. 5 12.0 14 12.6 78 13.2 96 13.9 233 14.5 13 15.1 140 15.7 2 16.4 8 17.0 Median 15.0 CEER This model: 14.7 CEER (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
12.0 - 12.6 CEER5Peer range
12.6 - 13.2 CEER14Peer range
13.2 - 13.9 CEER78Peer range
13.9 - 14.5 CEER96Peer range
14.5 - 15.1 CEER233This series
15.1 - 15.7 CEER13Peer range
15.7 - 16.4 CEER140Peer range
16.4 - 17.0 CEER2Peer range
17.0 - 17.6 CEER8Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
HOUSE KOBO KOBOGJC10BU residential equipment inspection. ThermalSpec Editorial Photography

How does HOUSE KOBO KOBOGJC10BU rank across federal compliance and ENERGY STAR cohorts?

HOUSE KOBO KOBOGJC10BU ranks #380 of 589 (tied with 10 others at 14.7 CEER, more efficient than 33.8% of certified series) for Max CEER (-0.30 CEER vs 15.0 CEER category median) across 1 certified SKU combination. Straddles Window 115V chassis (0.8 nominal Tons at 10,000 BTU/h) drawing 510.2 kWh/yr (35% less energy than federal baseline).

HOUSE KOBO KOBOGJC10BU Cohort Metrics vs. Room Air Conditioner Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max CEER) #380 of 589 (11 tied, beats 33.8% of peers) -0.30 CEER vs 15.0 CEER category median
Energy Margin vs Federal Std 35% less kWh -4.0% vs 39% median
DOE Annual Test Energy 510.2 kWh/yr -21.7 kWh vs 531.9 kWh median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
2026 Cleaner Refrigerant Rule COMPLIANT A2L Uses R-32 (cleaner low-warming refrigerant standard)
Electrical Supply Circuit 115V Standard 15A/20A 115V household receptacle
Variable-Speed Inverter Compressor INVERTER Variable-Speed

How much annual energy and operating cost does HOUSE KOBO KOBOGJC10BU require?

Modeled utility figures for HOUSE KOBO KOBOGJC10BU (HOUSE KOBO) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max CEER ratings.

Annual_USD = 510.2 kWh/yr (EPA 750-hr test) * $/kWh | Fed_Baseline_kWh = 510.2 / (1 - 0.35)

EPA ENERGY STAR annual kWh test basis at US median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
EPA Rated Annual Energy Consumption510.2 kWh/yr$83.32/yr at US median
State Operating Cost Spread$64.90 (NV)to $240.71/yr (HI)
Energy Saved vs US Federal Baseline274.7 kWh/yr (35%)$44.86/yr saved
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to HOUSE KOBO KOBOGJC10BU?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for HOUSE KOBO KOBOGJC10BU (PD ID 4481449).

KOBOGJC10BU Matched AHRI Coil 10,000 BTU/h

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on HOUSE KOBO KOBOGJC10BU, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across HOUSE KOBO KOBOGJC10BU: headline Max CEER reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for HOUSE KOBO KOBOGJC10BU exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal HOUSE KOBO KOBOGJC10BU fitSingle-family replacement needing documented ENERGY STAR PD ID 4481449 with matching indoor air handler.
Skip HOUSE KOBO KOBOGJC10BU ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable room air conditioner models deliver similar efficiency?

Compare HOUSE KOBO KOBOGJC10BU against GREE GJC10BU-A6DRNJ2A and closely matched room air conditioner units sharing similar Max CEER output and BTU tonnage.

GREE GJC10BU-A6DRNJ2A

14.7 CEER · 35% less kWh · 10,000 BTU/h

GE Profile PHNT10CCH1

14.7 CEER · 35% less kWh · 10,300 BTU/h

GREE GJC12BU-A6DRNJ2A

14.7 CEER · 35% less kWh · 11,500 BTU/h

GE Profile PHNT12CCH1

14.7 CEER · 35% less kWh · 12,200 BTU/h

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does HOUSE KOBO KOBOGJC10BU compare with peer Room Air Conditioner units?

HOUSE KOBO KOBOGJC10BU holds #380 of 589 (11 tied, beats 33.8% of peers) out of 589 verified room air conditioner models (-0.30 CEER vs 15.0 CEER category median), spanning 1 certified SKU up to 14.7 CEER. Closest same-cohort alternatives include GREE GJC10BU-A6DRNJ2A.

DOE Regions

Where is HOUSE KOBO KOBOGJC10BU compliant for 2026 US installation?

HOUSE KOBO KOBOGJC10BU: ENERGY STAR certified room air conditioner (14.7 CEER). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does HOUSE KOBO KOBOGJC10BU model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, HOUSE KOBO KOBOGJC10BU runs 510.2 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does HOUSE KOBO KOBOGJC10BU cover?

HOUSE KOBO KOBOGJC10BU covers 10,000-10,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does HOUSE KOBO KOBOGJC10BU handle extreme weather or cold snaps?

HOUSE KOBO KOBOGJC10BU is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern HOUSE KOBO KOBOGJC10BU?

HOUSE KOBO KOBOGJC10BU specifies R-32 compliance (PD ID 4481449); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in HOUSE KOBO KOBOGJC10BU reach 14.7 CEER?

Peak 14.7 CEER represents the top tested AHRI pairing for HOUSE KOBO KOBOGJC10BU (PD ID 4481449); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to HOUSE KOBO KOBOGJC10BU?

HOUSE KOBO KOBOGJC10BU requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include GREE GJC10BU-A6DRNJ2A.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros