HOUSE KOBO KOBOGJC08BU — Room Air Conditioner Specifications

HOUSE KOBO KOBOGJC08BU (Room Air Conditioner, PD ID 4481448) holds 1 ENERGY STAR certified SKU rated at 15.5 CEER — #152 of 589 (Top 26.1%, 3 tied), +0.50 CEER. ENERGY STAR certified room air conditioner (15.5 CEER). HOUSE KOBO KOBOGJC08BU — Room Air Conditioner Specifications benchmarks residential systems using Cooling CEER set at 15.5 CEER and Cohort Rank set at #152/589.

Cooling CEER
15.5 CEER
Cohort Rank
#152/589
Verified Combos
1 SKU
Sample PD ID
4481448
Room Air Conditioner Efficiency Spread across 589 certified series (12.0 to 17.6 CEER)
HOUSE KOBO KOBOGJC08BU Room Air Conditioner Efficiency Spread Distribution Distribution of 589 certified series from 12.0 to 17.6 CEER. HOUSE KOBO KOBOGJC08BU sits at 15.5 CEER; typical midpoint is 15.0 CEER. 5 12.0 14 12.6 78 13.2 96 13.9 233 14.5 13 15.1 140 15.7 2 16.4 8 17.0 Median 15.0 CEER This model: 15.5 CEER (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
12.0 - 12.6 CEER5Peer range
12.6 - 13.2 CEER14Peer range
13.2 - 13.9 CEER78Peer range
13.9 - 14.5 CEER96Peer range
14.5 - 15.1 CEER233Peer range
15.1 - 15.7 CEER13This series
15.7 - 16.4 CEER140Peer range
16.4 - 17.0 CEER2Peer range
17.0 - 17.6 CEER8Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
HOUSE KOBO KOBOGJC08BU residential equipment inspection. ThermalSpec Editorial Photography

How does HOUSE KOBO KOBOGJC08BU rank across federal compliance and ENERGY STAR cohorts?

HOUSE KOBO KOBOGJC08BU ranks #152 of 589 (tied with 2 others at 15.5 CEER, top 26.1%, more efficient than 73.9% of certified series) for Max CEER (+0.50 CEER vs 15.0 CEER category median) across 1 certified SKU combination. Straddles Window 115V chassis (0.7 nominal Tons at 8,100 BTU/h) drawing 391.9 kWh/yr (42% less energy than federal baseline).

HOUSE KOBO KOBOGJC08BU Cohort Metrics vs. Room Air Conditioner Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max CEER) #152 of 589 (Top 26.1%, 3 tied) +0.50 CEER vs 15.0 CEER category median
Energy Margin vs Federal Std 42% less kWh +3.0% vs 39% median
DOE Annual Test Energy 391.9 kWh/yr -140.0 kWh vs 531.9 kWh median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
2026 Cleaner Refrigerant Rule COMPLIANT A2L Uses R-32 (cleaner low-warming refrigerant standard)
Electrical Supply Circuit 115V Standard 15A/20A 115V household receptacle
Variable-Speed Inverter Compressor INVERTER Variable-Speed

How much annual energy and operating cost does HOUSE KOBO KOBOGJC08BU require?

Annual cost outputs combine HOUSE KOBO KOBOGJC08BU's 15.5 CEER rating and EIA national tariffs across single-family runtime hours.

Annual_USD = 391.9 kWh/yr (EPA 750-hr test) * $/kWh | Fed_Baseline_kWh = 391.9 / (1 - 0.42)

EPA ENERGY STAR annual kWh test basis at US median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
EPA Rated Annual Energy Consumption391.9 kWh/yr$64.00/yr at US median
State Operating Cost Spread$49.85 (NV)to $184.90/yr (HI)
Energy Saved vs US Federal Baseline283.8 kWh/yr (42%)$46.34/yr saved
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to HOUSE KOBO KOBOGJC08BU?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for HOUSE KOBO KOBOGJC08BU (PD ID 4481448).

KOBOGJC08BU Matched AHRI Coil 8,100 BTU/h

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on HOUSE KOBO KOBOGJC08BU, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across HOUSE KOBO KOBOGJC08BU: headline Max CEER reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for HOUSE KOBO KOBOGJC08BU exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal HOUSE KOBO KOBOGJC08BU fitSingle-family replacement needing documented ENERGY STAR PD ID 4481448 with matching indoor air handler.
Skip HOUSE KOBO KOBOGJC08BU ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable room air conditioner models deliver similar efficiency?

Compare HOUSE KOBO KOBOGJC08BU against LG LW8022IVSM and closely matched room air conditioner units sharing similar Max CEER output and BTU tonnage.

LG LW8022IVSM

15.5 CEER · 42% less kWh · 8,000 BTU/h

LG LW6023IVSM

15.5 CEER · 41% less kWh · 6,000 BTU/h

GE Profile AHTR12ACH2

15.4 CEER · 41% less kWh · 12,200 BTU/h

GE Profile AHTR10ACH2

15.7 CEER · 44% less kWh · 10,100 BTU/h

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does HOUSE KOBO KOBOGJC08BU compare with peer Room Air Conditioner units?

HOUSE KOBO KOBOGJC08BU holds #152 of 589 (Top 26.1%, 3 tied) out of 589 verified room air conditioner models (+0.50 CEER vs 15.0 CEER category median), spanning 1 certified SKU up to 15.5 CEER. Closest same-cohort alternatives include LG LW8022IVSM.

DOE Regions

Where is HOUSE KOBO KOBOGJC08BU compliant for 2026 US installation?

HOUSE KOBO KOBOGJC08BU: ENERGY STAR certified room air conditioner (15.5 CEER). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does HOUSE KOBO KOBOGJC08BU model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, HOUSE KOBO KOBOGJC08BU runs 391.9 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does HOUSE KOBO KOBOGJC08BU cover?

HOUSE KOBO KOBOGJC08BU covers 8,100-8,100 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does HOUSE KOBO KOBOGJC08BU handle extreme weather or cold snaps?

HOUSE KOBO KOBOGJC08BU is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern HOUSE KOBO KOBOGJC08BU?

HOUSE KOBO KOBOGJC08BU specifies R-32 compliance (PD ID 4481448); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in HOUSE KOBO KOBOGJC08BU reach 15.5 CEER?

Peak 15.5 CEER represents the top tested AHRI pairing for HOUSE KOBO KOBOGJC08BU (PD ID 4481448); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to HOUSE KOBO KOBOGJC08BU?

HOUSE KOBO KOBOGJC08BU requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include LG LW8022IVSM.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 7 pages.

Comparable HVAC Climate & Cost Metros