GE Profile AHTR14AC*# — Room Air Conditioner Specifications
GE Profile AHTR14AC*# (Room Air Conditioner, PD ID 2684129) holds 1 ENERGY STAR certified SKU rated at 14.7 CEER — #380 of 589 (11 tied, beats 33.8% of peers), -0.30 CEER. ENERGY STAR certified room air conditioner (14.7 CEER). GE Profile AHTR14AC*# — Room Air Conditioner Specifications benchmarks residential systems using Cooling CEER set at 14.7 CEER and Cohort Rank set at #380/589.
- Cooling CEER
- 14.7 CEER
- Cohort Rank
- #380/589
- Verified Combos
- 1 SKU
- Sample PD ID
- 2684129
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 12.0 - 12.6 CEER | 5 | Peer range |
| 12.6 - 13.2 CEER | 14 | Peer range |
| 13.2 - 13.9 CEER | 78 | Peer range |
| 13.9 - 14.5 CEER | 96 | Peer range |
| 14.5 - 15.1 CEER | 233 | This series |
| 15.1 - 15.7 CEER | 13 | Peer range |
| 15.7 - 16.4 CEER | 140 | Peer range |
| 16.4 - 17.0 CEER | 2 | Peer range |
| 17.0 - 17.6 CEER | 8 | Peer range |
How does GE Profile AHTR14AC*# rank across federal compliance and ENERGY STAR cohorts?
GE Profile AHTR14AC*# ranks #380 of 589 (tied with 10 others at 14.7 CEER, more efficient than 33.8% of certified series) for Max CEER (-0.30 CEER vs 15.0 CEER category median) across 1 certified SKU combination. Does Not Straddle Window or Windowsill 115V chassis (1.1 nominal Tons at 13,500 BTU/h) drawing 688.8 kWh/yr (35% less energy than federal baseline).
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max CEER) | #380 of 589 (11 tied, beats 33.8% of peers) | -0.30 CEER vs 15.0 CEER category median |
| Energy Margin vs Federal Std | 35% less kWh | -4.0% vs 39% median |
| DOE Annual Test Energy | 688.8 kWh/yr | +156.9 kWh vs 531.9 kWh median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| 2026 Cleaner Refrigerant Rule | COMPLIANT A2L | Uses R-32 (cleaner low-warming refrigerant standard) |
| Electrical Supply Circuit | 115V | Standard 15A/20A 115V household receptacle |
| Variable-Speed Inverter Compressor | INVERTER | Variable-Speed |
How much annual energy and operating cost does GE Profile AHTR14AC*# require?
Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, GE Profile AHTR14AC*# estimates reflect 1 certified SKU combination tested under PD ID 2684129.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| EPA Rated Annual Energy Consumption | 688.8 kWh/yr | $112.48/yr at US median |
| State Operating Cost Spread | $87.62 (NV) | to $324.98/yr (HI) |
| Energy Saved vs US Federal Baseline | 370.9 kWh/yr (35%) | $60.57/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to GE Profile AHTR14AC*#?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for GE Profile AHTR14AC*# (PD ID 2684129).
| AHTR14AC*# | Matched AHRI Coil | 13,500 BTU/h |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on GE Profile AHTR14AC*#, review 2 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across GE Profile AHTR14AC*#: headline Max CEER reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for GE Profile AHTR14AC*# exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal GE Profile AHTR14AC*# fit | Single-family replacement needing documented ENERGY STAR PD ID 2684129 with matching indoor air handler. |
| Skip GE Profile AHTR14AC*# if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable room air conditioner models deliver similar efficiency?
Compare GE Profile AHTR14AC*# against Friedrich KCVM14B10A and closely matched room air conditioner units sharing similar Max CEER output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does GE Profile AHTR14AC*# compare with peer Room Air Conditioner units?
GE Profile AHTR14AC*# holds #380 of 589 (11 tied, beats 33.8% of peers) out of 589 verified room air conditioner models (-0.30 CEER vs 15.0 CEER category median), spanning 1 certified SKU up to 14.7 CEER. Closest same-cohort alternatives include Friedrich KCVM14B10A.
Where is GE Profile AHTR14AC*# compliant for 2026 US installation?
GE Profile AHTR14AC*#: ENERGY STAR certified room air conditioner (14.7 CEER). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does GE Profile AHTR14AC*# model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, GE Profile AHTR14AC*# runs 688.8 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does GE Profile AHTR14AC*# cover?
GE Profile AHTR14AC*# covers 13,500-13,500 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does GE Profile AHTR14AC*# handle extreme weather or cold snaps?
GE Profile AHTR14AC*# is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.
What refrigerant class and 2026 tax credit rules govern GE Profile AHTR14AC*#?
GE Profile AHTR14AC*# specifies R-32 compliance (PD ID 2684129); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in GE Profile AHTR14AC*# reach 14.7 CEER?
Peak 14.7 CEER represents the top tested AHRI pairing for GE Profile AHTR14AC*# (PD ID 2684129); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to GE Profile AHTR14AC*#?
GE Profile AHTR14AC*# requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Friedrich KCVM14B10A.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)