Skip to main content
Room Air Conditioner · Frigidaire Gallery · 1 ENERGY STAR Combinations

Frigidaire Gallery GHWW085TF1 — Room Air Conditioner Specifications

Frigidaire Gallery GHWW085TF1 (Room Air Conditioner, PD ID 4699254) holds 1 ENERGY STAR certified SKU rated at 15.1 CEER — #164 of 589 (Top 31.2%, 21 tied), +0.10 CEER. ENERGY STAR certified room air conditioner (15.1 CEER). Frigidaire Gallery GHWW085TF1 — Room Air Conditioner Specifications benchmarks residential systems using Cooling CEER set at 15.1 CEER and Cohort Rank set at #164/589.

Cooling CEER
15.1 CEER
Cohort Rank
#164/589
Verified Combos
1 SKU
Sample PD ID
4699254
Room Air Conditioner Efficiency Spread across 589 certified series (12.0 to 17.6 CEER)
Frigidaire Gallery GHWW085TF1 Room Air Conditioner Efficiency Spread Distribution Distribution of 589 certified series from 12.0 to 17.6 CEER. Frigidaire Gallery GHWW085TF1 sits at 15.1 CEER; typical midpoint is 15.0 CEER. 5 12.0 14 12.6 78 13.2 96 13.9 233 14.5 13 15.1 140 15.7 2 16.4 8 17.0 Median 15.0 CEER This model: 15.1 CEER (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
12.0 - 12.6 CEER5Peer range
12.6 - 13.2 CEER14Peer range
13.2 - 13.9 CEER78Peer range
13.9 - 14.5 CEER96Peer range
14.5 - 15.1 CEER233This series
15.1 - 15.7 CEER13Peer range
15.7 - 16.4 CEER140Peer range
16.4 - 17.0 CEER2Peer range
17.0 - 17.6 CEER8Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
Frigidaire Gallery GHWW085TF1 residential equipment inspection. ThermalSpec Editorial Photography

How does Frigidaire Gallery GHWW085TF1 rank across federal compliance and ENERGY STAR cohorts?

Frigidaire Gallery GHWW085TF1 ranks #164 of 589 (tied with 20 others at 15.1 CEER, top 31.2%, more efficient than 68.8% of certified series) for Max CEER (+0.10 CEER vs 15.0 CEER category median) across 1 certified SKU combination. Does Not Straddle Window or Windowsill 115V chassis (0.7 nominal Tons at 7,800 BTU/h) drawing 387.4 kWh/yr (37% less energy than federal baseline).

Frigidaire Gallery GHWW085TF1 Cohort Metrics vs. Room Air Conditioner Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max CEER) #164 of 589 (Top 31.2%, 21 tied) +0.10 CEER vs 15.0 CEER category median
Energy Margin vs Federal Std 37% less kWh -2.0% vs 39% median
DOE Annual Test Energy 387.4 kWh/yr -144.5 kWh vs 531.9 kWh median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
2026 Cleaner Refrigerant Rule COMPLIANT A2L Uses R-32 (cleaner low-warming refrigerant standard)
Electrical Supply Circuit 115V Standard 15A/20A 115V household receptacle
Variable-Speed Inverter Compressor INVERTER Variable-Speed

How much annual energy and operating cost does Frigidaire Gallery GHWW085TF1 require?

Annual cost outputs combine Frigidaire Gallery GHWW085TF1's 15.1 CEER rating and EIA national tariffs across single-family runtime hours.

Annual_USD = 387.4 kWh/yr (EPA 750-hr test) * $/kWh | Fed_Baseline_kWh = 387.4 / (1 - 0.37)

EPA ENERGY STAR annual kWh test basis at US median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
EPA Rated Annual Energy Consumption387.4 kWh/yr$63.26/yr at US median
State Operating Cost Spread$49.28 (NV)to $182.78/yr (HI)
Energy Saved vs US Federal Baseline227.5 kWh/yr (37%)$37.15/yr saved
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to Frigidaire Gallery GHWW085TF1?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Frigidaire Gallery GHWW085TF1 (PD ID 4699254).

GHWW085TF1 Matched AHRI Coil 7,800 BTU/h

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Frigidaire Gallery GHWW085TF1, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Frigidaire Gallery GHWW085TF1: headline Max CEER reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for Frigidaire Gallery GHWW085TF1 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal Frigidaire Gallery GHWW085TF1 fitSingle-family replacement needing documented ENERGY STAR PD ID 4699254 with matching indoor air handler.
Skip Frigidaire Gallery GHWW085TF1 ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable room air conditioner models deliver similar efficiency?

Compare Frigidaire Gallery GHWW085TF1 against Midea MAW08Q1CWK and closely matched room air conditioner units sharing similar Max CEER output and BTU tonnage.

Midea MAW08Q1CWK

15.1 CEER · 37% less kWh · 7,800 BTU/h

Midea MAW08U1KWT-A

15.1 CEER · 37% less kWh · 7,800 BTU/h

Midea MAW08U1KWT-M

15.1 CEER · 37% less kWh · 7,800 BTU/h

Midea MAW08V1KWT-A

15.1 CEER · 37% less kWh · 7,800 BTU/h

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Frigidaire Gallery GHWW085TF1 compare with peer Room Air Conditioner units?

Frigidaire Gallery GHWW085TF1 holds #164 of 589 (Top 31.2%, 21 tied) out of 589 verified room air conditioner models (+0.10 CEER vs 15.0 CEER category median), spanning 1 certified SKU up to 15.1 CEER. Closest same-cohort alternatives include Midea MAW08Q1CWK.

DOE Regions

Where is Frigidaire Gallery GHWW085TF1 compliant for 2026 US installation?

Frigidaire Gallery GHWW085TF1: ENERGY STAR certified room air conditioner (15.1 CEER). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Frigidaire Gallery GHWW085TF1 model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Frigidaire Gallery GHWW085TF1 runs 387.4 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Frigidaire Gallery GHWW085TF1 cover?

Frigidaire Gallery GHWW085TF1 covers 7,800-7,800 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Frigidaire Gallery GHWW085TF1 handle extreme weather or cold snaps?

Frigidaire Gallery GHWW085TF1 is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Frigidaire Gallery GHWW085TF1?

Frigidaire Gallery GHWW085TF1 specifies R-32 compliance (PD ID 4699254); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in Frigidaire Gallery GHWW085TF1 reach 15.1 CEER?

Peak 15.1 CEER represents the top tested AHRI pairing for Frigidaire Gallery GHWW085TF1 (PD ID 4699254); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Frigidaire Gallery GHWW085TF1?

Frigidaire Gallery GHWW085TF1 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Midea MAW08Q1CWK.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros