Room Air Conditioner · Friedrich · 1 ENERGY STAR Combinations

Friedrich CCV18A30A — Room Air Conditioner Specifications

Friedrich CCV18A30A (Room Air Conditioner, PD ID 3478068) holds 1 ENERGY STAR certified SKU rated at 14.4 CEER — #397 of 589 (31 tied, beats 27.5% of peers), -0.60 CEER. ENERGY STAR certified room air conditioner (14.4 CEER). Friedrich CCV18A30A — Room Air Conditioner Specifications benchmarks residential systems using Cooling CEER set at 14.4 CEER and Cohort Rank set at #397/589.

Cooling CEER
14.4 CEER
Cohort Rank
#397/589
Verified Combos
1 SKU
Sample PD ID
3478068
Room Air Conditioner Efficiency Spread across 589 certified series (12.0 to 17.6 CEER)
Friedrich CCV18A30A Room Air Conditioner Efficiency Spread Distribution Distribution of 589 certified series from 12.0 to 17.6 CEER. Friedrich CCV18A30A sits at 14.4 CEER; typical midpoint is 15.0 CEER. 5 12.0 14 12.6 78 13.2 96 13.9 233 14.5 13 15.1 140 15.7 2 16.4 8 17.0 Median 15.0 CEER This model: 14.4 CEER (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
12.0 - 12.6 CEER5Peer range
12.6 - 13.2 CEER14Peer range
13.2 - 13.9 CEER78Peer range
13.9 - 14.5 CEER96This series
14.5 - 15.1 CEER233Peer range
15.1 - 15.7 CEER13Peer range
15.7 - 16.4 CEER140Peer range
16.4 - 17.0 CEER2Peer range
17.0 - 17.6 CEER8Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
Friedrich CCV18A30A residential equipment inspection. ThermalSpec Editorial Photography

How does Friedrich CCV18A30A rank across federal compliance and ENERGY STAR cohorts?

Friedrich CCV18A30A ranks #397 of 589 (tied with 30 others at 14.4 CEER, more efficient than 27.5% of certified series) for Max CEER (-0.60 CEER vs 15.0 CEER category median) across 1 certified SKU combination. Straddles Window 230V chassis (1.5 nominal Tons at 18,000 BTU/h) drawing 937.5 kWh/yr (35% less energy than federal baseline).

Friedrich CCV18A30A Cohort Metrics vs. Room Air Conditioner Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max CEER) #397 of 589 (31 tied, beats 27.5% of peers) -0.60 CEER vs 15.0 CEER category median
Energy Margin vs Federal Std 35% less kWh -4.0% vs 39% median
DOE Annual Test Energy 937.5 kWh/yr +405.6 kWh vs 531.9 kWh median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
2026 Cleaner Refrigerant Rule COMPLIANT A2L Uses R-32 (cleaner low-warming refrigerant standard)
Electrical Supply Circuit 230V Requires dedicated 208/230V NEMA 6-15/6-20 receptacle
Variable-Speed Inverter Compressor INVERTER Variable-Speed

How much annual energy and operating cost does Friedrich CCV18A30A require?

Annual cost outputs combine Friedrich CCV18A30A's 14.4 CEER rating and EIA national tariffs across single-family runtime hours.

Annual_USD = 937.5 kWh/yr (EPA 750-hr test) * $/kWh | Fed_Baseline_kWh = 937.5 / (1 - 0.35)

EPA ENERGY STAR annual kWh test basis at US median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
EPA Rated Annual Energy Consumption937.5 kWh/yr$153.09/yr at US median
State Operating Cost Spread$119.25 (NV)to $442.31/yr (HI)
Energy Saved vs US Federal Baseline504.8 kWh/yr (35%)$82.43/yr saved
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to Friedrich CCV18A30A?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Friedrich CCV18A30A (PD ID 3478068).

CCV18A30A Matched AHRI Coil 18,000 BTU/h

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Friedrich CCV18A30A, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Friedrich CCV18A30A: headline Max CEER reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for Friedrich CCV18A30A exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal Friedrich CCV18A30A fitSingle-family replacement needing documented ENERGY STAR PD ID 3478068 with matching indoor air handler.
Skip Friedrich CCV18A30A ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable room air conditioner models deliver similar efficiency?

Compare Friedrich CCV18A30A against HEMA DS-2W1822CI and closely matched room air conditioner units sharing similar Max CEER output and BTU tonnage.

HEMA DS-2W1822CI

14.4 CEER · 35% less kWh · 18,000 BTU/h

TCL H18W4KW

14.4 CEER · 35% less kWh · 18,000 BTU/h

TCL H18W4KW-CA

14.4 CEER · 35% less kWh · 18,000 BTU/h

TCL T18WQ2S

14.4 CEER · 35% less kWh · 18,000 BTU/h

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Friedrich CCV18A30A compare with peer Room Air Conditioner units?

Friedrich CCV18A30A holds #397 of 589 (31 tied, beats 27.5% of peers) out of 589 verified room air conditioner models (-0.60 CEER vs 15.0 CEER category median), spanning 1 certified SKU up to 14.4 CEER. Closest same-cohort alternatives include HEMA DS-2W1822CI.

DOE Regions

Where is Friedrich CCV18A30A compliant for 2026 US installation?

Friedrich CCV18A30A: ENERGY STAR certified room air conditioner (14.4 CEER). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Friedrich CCV18A30A model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Friedrich CCV18A30A runs 937.5 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Friedrich CCV18A30A cover?

Friedrich CCV18A30A covers 18,000-18,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Friedrich CCV18A30A handle extreme weather or cold snaps?

Friedrich CCV18A30A is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Friedrich CCV18A30A?

Friedrich CCV18A30A specifies R-32 compliance (PD ID 3478068); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in Friedrich CCV18A30A reach 14.4 CEER?

Peak 14.4 CEER represents the top tested AHRI pairing for Friedrich CCV18A30A (PD ID 3478068); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Friedrich CCV18A30A?

Friedrich CCV18A30A requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include HEMA DS-2W1822CI.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros