York YPAS18BUFASDQ1 — Mini-Split Heat Pump Specifications
York YPAS18BUFASDQ1 (Mini-Split Heat Pump, PD ID 4680179) holds 1 ENERGY STAR certified SKU rated at 25.0 SEER2 — #1,069 of 2,096 (311 tied, beats 34.2% of peers), -0.10 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). York YPAS18BUFASDQ1 — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 25.0 SEER2 and Heating Rating set at 11.0 HSPF2.
- Max SEER2
- 25.0 SEER2
- Heating Rating
- 11.0 HSPF2
- Heating COP
- 2.6 COP
- Cohort Rank
- #1,069/2,096
- Verified Combos
- 1 SKU
- Sample PD ID
- 4680179
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | Peer range |
| 25.0 - 26.2 SEER2 | 785 | This series |
| 26.2 - 27.5 SEER2 | 272 | Peer range |
| 27.5 - 28.8 SEER2 | 150 | Peer range |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |
How does York YPAS18BUFASDQ1 rank across federal compliance and ENERGY STAR cohorts?
York YPAS18BUFASDQ1 ranks #1,069 of 2,096 (tied with 310 others at 25.0 SEER2, more efficient than 34.2% of certified series) for Max SEER2 (-0.10 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (81.0% capacity retention at 5F) (1.5 nominal Tons at 18,000 BTU/h) charged with R-32. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #1,069 of 2,096 (311 tied, beats 34.2% of peers) | -0.10 SEER2 vs 25.1 SEER2 category median |
| Heating HSPF2 vs Cohort | 11.0 HSPF2 | +0.50 HSPF2 vs 10.5 HSPF2 median |
| Peak 95F EER2 vs Cohort | 15.0 EER2 | +1.00 EER2 vs 14.0 EER2 median |
| 5F Cold-Weather Capacity Retention | 81.0% of 47F rating | 5F COP 2.6 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 25.0 SEER2 / 11.0 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 15.0 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (1947/2096 series in category) |
| 2026 Cleaner Refrigerant Rule | R-454B / R-32 READY | Listed refrigerant: R-32; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does York YPAS18BUFASDQ1 require?
Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, York YPAS18BUFASDQ1 estimates reflect 1 certified SKU combination tested under PD ID 4680179.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 720 kWh/yr | $118/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 2,727 kWh/yr | $445/yr at US median |
| Combined Annual Electricity Cost | $563/yr | State range: $438 (NV) to $1,626 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 1,812 kWh/yr | $296/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to York YPAS18BUFASDQ1?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for York YPAS18BUFASDQ1 (PD ID 4680179).
| YPAS18BUFASDQ1 | YPCIB18UFA1DQ | 18,000 BTU/h | 25.0 SEER2 / 11.0 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on York YPAS18BUFASDQ1, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across York YPAS18BUFASDQ1: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for York YPAS18BUFASDQ1 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- York YPAS18BUFASDQ1 uses A2L R-32, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal York YPAS18BUFASDQ1 fit | Single-family replacement needing documented ENERGY STAR PD ID 4680179 with matching indoor air handler. |
| Skip York YPAS18BUFASDQ1 if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable mini-split heat pump models deliver similar efficiency?
Compare York YPAS18BUFASDQ1 against ALBOTT BI08W6-1B5A0 and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does York YPAS18BUFASDQ1 compare with peer Mini-Split Heat Pump units?
York YPAS18BUFASDQ1 holds #1,069 of 2,096 (311 tied, beats 34.2% of peers) out of 2,096 verified mini-split heat pump models (-0.10 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 25.0 SEER2. Closest same-cohort alternatives include ALBOTT BI08W6-1B5A0.
Where is York YPAS18BUFASDQ1 compliant for 2026 US installation?
York YPAS18BUFASDQ1: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does York YPAS18BUFASDQ1 model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, York YPAS18BUFASDQ1 runs 720 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does York YPAS18BUFASDQ1 cover?
York YPAS18BUFASDQ1 covers 18,000-18,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does York YPAS18BUFASDQ1 handle extreme weather or cold snaps?
Yes, York YPAS18BUFASDQ1 carries ENERGY STAR Cold Climate certification (81.0% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern York YPAS18BUFASDQ1?
York YPAS18BUFASDQ1 specifies R-32 compliance (PD ID 4680179); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in York YPAS18BUFASDQ1 reach 25.0 SEER2?
Peak 25.0 SEER2 represents the top tested AHRI pairing for York YPAS18BUFASDQ1 (PD ID 4680179); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to York YPAS18BUFASDQ1?
York YPAS18BUFASDQ1 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include ALBOTT BI08W6-1B5A0.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.