Mini-Split Heat Pump · VENTAGEN · 1 ENERGY STAR Combinations

VENTAGEN TSVH12EI2N24TO454 — Mini-Split Heat Pump Specifications

VENTAGEN TSVH12EI2N24TO454 (Mini-Split Heat Pump, PD ID 4577204) holds 1 ENERGY STAR certified SKU rated at 24.0 SEER2 — #1,599 of 2,096 (411 tied, beats 4.2% of peers), -1.10 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). VENTAGEN TSVH12EI2N24TO454 — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 24.0 SEER2 and Heating Rating set at 10.0 HSPF2.

Max SEER2
24.0 SEER2
Heating Rating
10.0 HSPF2
Heating COP
2.1 COP
Cohort Rank
#1,599/2,096
Verified Combos
1 SKU
Sample PD ID
4577204
Mini-Split Heat Pump Efficiency Spread across 2096 certified series (23.7 to 35.1 SEER2)
VENTAGEN TSVH12EI2N24TO454 Mini-Split Heat Pump Efficiency Spread Distribution Distribution of 2096 certified series from 23.7 to 35.1 SEER2. VENTAGEN TSVH12EI2N24TO454 sits at 24.0 SEER2; typical midpoint is 25.1 SEER2. 717 23.7 785 25.0 272 26.2 150 27.5 86 28.8 1 30.0 28 31.3 38 32.6 19 33.8 Median 25.1 SEER2 This model: 24.0 SEER2 (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
23.7 - 25.0 SEER2717This series
25.0 - 26.2 SEER2785Peer range
26.2 - 27.5 SEER2272Peer range
27.5 - 28.8 SEER2150Peer range
28.8 - 30.0 SEER286Peer range
30.0 - 31.3 SEER21Peer range
31.3 - 32.6 SEER228Peer range
32.6 - 33.8 SEER238Peer range
33.8 - 35.1 SEER219Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
VENTAGEN TSVH12EI2N24TO454 residential equipment inspection. ThermalSpec Editorial Photography

How does VENTAGEN TSVH12EI2N24TO454 rank across federal compliance and ENERGY STAR cohorts?

VENTAGEN TSVH12EI2N24TO454 ranks #1,599 of 2,096 (tied with 410 others at 24.0 SEER2, more efficient than 4.2% of certified series) for Max SEER2 (-1.10 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (72.2% capacity retention at 5F) (1.0 nominal Tons at 12,000 BTU/h) charged with R-454B. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.

VENTAGEN TSVH12EI2N24TO454 Cohort Metrics vs. Mini-Split Heat Pump Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max SEER2) #1,599 of 2,096 (411 tied, beats 4.2% of peers) -1.10 SEER2 vs 25.1 SEER2 category median
Heating HSPF2 vs Cohort 10.0 HSPF2 -0.50 HSPF2 vs 10.5 HSPF2 median
Peak 95F EER2 vs Cohort 13.0 EER2 -1.00 EER2 vs 14.0 EER2 median
5F Cold-Weather Capacity Retention 72.2% of 47F rating 5F COP 2.1
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Federal North & SE Heat Pump Minimum PASS Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 24.0 SEER2 / 10.0 HSPF2
Southwest Peak-Heat Criterion (AZ/CA/NM/NV) PASS Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 13.0 EER2
ENERGY STAR Cold Climate Spec CERTIFIED Cold Climate verified (1947/2096 series in category)
2026 Cleaner Refrigerant Rule R-454B / R-32 READY Listed refrigerant: R-454B; newer R-454B/R-32 splits include indoor leak sensors

How much annual energy and operating cost does VENTAGEN TSVH12EI2N24TO454 require?

Annual cost outputs combine VENTAGEN TSVH12EI2N24TO454's 24.0 SEER2 rating and EIA national tariffs across single-family runtime hours.

Cool_kWh = (12,000 BTU/h * 1,000 hrs / 24.0 SEER2) / 1,000 | Heat_kWh = 30,000 kBTU / 10.0 HSPF2

Assumes 1,000 cooling hrs + 30 MMBtu heating at US 51-state median 16.33 c/kWh (range 12.72 c NV to 47.18 c HI)

Operating BasisEstimated ValueSource Basis
Estimated Annual Cooling Energy500 kWh/yr$82/yr at US median
Estimated Annual Heating Energy (30 MMBtu)3,000 kWh/yr$490/yr at US median
Combined Annual Electricity Cost$572/yrState range: $445 (NV) to $1,651 (HI)
Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor1,339 kWh/yr$219/yr saved
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to VENTAGEN TSVH12EI2N24TO454?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for VENTAGEN TSVH12EI2N24TO454 (PD ID 4577204).

TSVH12EI2N24TO454 TSVH12EI2N24TI454 12,000 BTU/h 24.0 SEER2 / 10.0 HSPF2

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on VENTAGEN TSVH12EI2N24TO454, review 3 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across VENTAGEN TSVH12EI2N24TO454: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for VENTAGEN TSVH12EI2N24TO454 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
  • VENTAGEN TSVH12EI2N24TO454 uses A2L R-454B, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
Homeowner ScenarioRecommended Verification Path
Ideal VENTAGEN TSVH12EI2N24TO454 fitSingle-family replacement needing documented ENERGY STAR PD ID 4577204 with matching indoor air handler.
Skip VENTAGEN TSVH12EI2N24TO454 ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable mini-split heat pump models deliver similar efficiency?

Compare VENTAGEN TSVH12EI2N24TO454 against NOVAIR LEA12SZ-R32-O and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.

NOVAIR LEA12SZ-R32-O

24.0 SEER2 · 10.0 HSPF2 · 12,000 BTU/h

PerfectAire 4PAMSHH12-SZO

24.0 SEER2 · 10.5 HSPF2 · 12,000 BTU/h

Pioneer YN012GLSI24RPG

24.0 SEER2 · 10.0 HSPF2 · 12,000 BTU/h

Pioneer YN012GLUI25RPQ

24.0 SEER2 · 9.5 HSPF2 · 12,000 BTU/h

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does VENTAGEN TSVH12EI2N24TO454 compare with peer Mini-Split Heat Pump units?

VENTAGEN TSVH12EI2N24TO454 holds #1,599 of 2,096 (411 tied, beats 4.2% of peers) out of 2,096 verified mini-split heat pump models (-1.10 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 24.0 SEER2. Closest same-cohort alternatives include NOVAIR LEA12SZ-R32-O.

DOE Regions

Where is VENTAGEN TSVH12EI2N24TO454 compliant for 2026 US installation?

VENTAGEN TSVH12EI2N24TO454: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does VENTAGEN TSVH12EI2N24TO454 model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, VENTAGEN TSVH12EI2N24TO454 runs 500 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does VENTAGEN TSVH12EI2N24TO454 cover?

VENTAGEN TSVH12EI2N24TO454 covers 12,000-12,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does VENTAGEN TSVH12EI2N24TO454 handle extreme weather or cold snaps?

Yes, VENTAGEN TSVH12EI2N24TO454 carries ENERGY STAR Cold Climate certification (72.2% capacity retention at 5 F).

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern VENTAGEN TSVH12EI2N24TO454?

VENTAGEN TSVH12EI2N24TO454 specifies R-454B compliance (PD ID 4577204); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in VENTAGEN TSVH12EI2N24TO454 reach 24.0 SEER2?

Peak 24.0 SEER2 represents the top tested AHRI pairing for VENTAGEN TSVH12EI2N24TO454 (PD ID 4577204); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to VENTAGEN TSVH12EI2N24TO454?

VENTAGEN TSVH12EI2N24TO454 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include NOVAIR LEA12SZ-R32-O.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)