TCL H27FMHD4XPC — Mini-Split Heat Pump Specifications
TCL H27FMHD4XPC (Mini-Split Heat Pump, PD ID 4691437) holds 2 ENERGY STAR certified SKUs rated at 26.5 SEER2 — #467 of 2,096 (Top 25.9%, 76 tied), +1.40 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). TCL H27FMHD4XPC — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 26.5 SEER2 and Heating Rating set at 10.5 HSPF2.
- Max SEER2
- 26.5 SEER2
- Heating Rating
- 10.5 HSPF2
- Heating COP
- 2.0 COP
- Cohort Rank
- #467/2,096
- Verified Combos
- 2 SKUs
- Sample PD ID
- 4691437
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | Peer range |
| 25.0 - 26.2 SEER2 | 785 | Peer range |
| 26.2 - 27.5 SEER2 | 272 | This series |
| 27.5 - 28.8 SEER2 | 150 | Peer range |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |
How does TCL H27FMHD4XPC rank across federal compliance and ENERGY STAR cohorts?
TCL H27FMHD4XPC ranks #467 of 2,096 (tied with 75 others at 26.5 SEER2, top 25.9%, more efficient than 74.1% of certified series) for Max SEER2 (+1.40 SEER2 vs 25.1 SEER2 category median) across 2 certified SKU combinations. Rated for cold-climate output (96.3% capacity retention at 5F) (2.2 nominal Tons at 27,000 BTU/h) charged with R-454B. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #467 of 2,096 (Top 25.9%, 76 tied) | +1.40 SEER2 vs 25.1 SEER2 category median |
| Heating HSPF2 vs Cohort | 10.5 HSPF2 | Equal to 10.5 HSPF2 median |
| Peak 95F EER2 vs Cohort | 14.0 EER2 | Equal to 14.0 EER2 median |
| 5F Cold-Weather Capacity Retention | 96.3% of 47F rating | 5F COP 2.0 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 26.5 SEER2 / 10.5 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 14.0 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (1947/2096 series in category) |
| 2026 Cleaner Refrigerant Rule | R-454B / R-32 READY | Listed refrigerant: R-454B; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does TCL H27FMHD4XPC require?
Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, TCL H27FMHD4XPC estimates reflect 2 certified SKU combinations tested under PD ID 4691437.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 1,019 kWh/yr | $166/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 2,857 kWh/yr | $467/yr at US median |
| Combined Annual Electricity Cost | $633/yr | State range: $493 (NV) to $1,829 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 2,012 kWh/yr | $329/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to TCL H27FMHD4XPC?
Showing 2 certified indoor-outdoor coil combinations from 2 total AHRI matched records filed for TCL H27FMHD4XPC (PD ID 4691437).
| H27FMHD4XPC | Matched AHRI Coil | 27,000 BTU/h | 26.5 SEER2 / 10.5 HSPF2 |
| H27FMHD4XPC | Matched AHRI Coil | 27,000 BTU/h | 24.2 SEER2 / 10.5 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on TCL H27FMHD4XPC, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across TCL H27FMHD4XPC: headline Max SEER2 reflects peak tested matches among 2 SKUs, not lower-rated sizes.
- Catalog specs for TCL H27FMHD4XPC exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- TCL H27FMHD4XPC uses A2L R-454B, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal TCL H27FMHD4XPC fit | Single-family replacement needing documented ENERGY STAR PD ID 4691437 with matching indoor air handler. |
| Skip TCL H27FMHD4XPC if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable mini-split heat pump models deliver similar efficiency?
Compare TCL H27FMHD4XPC against Clima Smart MU-CSU27HEI2NAM0T24-4PO and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does TCL H27FMHD4XPC compare with peer Mini-Split Heat Pump units?
TCL H27FMHD4XPC holds #467 of 2,096 (Top 25.9%, 76 tied) out of 2,096 verified mini-split heat pump models (+1.40 SEER2 vs 25.1 SEER2 category median), spanning 2 certified SKUs up to 26.5 SEER2. Closest same-cohort alternatives include Clima Smart MU-CSU27HEI2NAM0T24-4PO.
Where is TCL H27FMHD4XPC compliant for 2026 US installation?
TCL H27FMHD4XPC: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does TCL H27FMHD4XPC model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, TCL H27FMHD4XPC runs 1,019 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does TCL H27FMHD4XPC cover?
TCL H27FMHD4XPC covers 27,000-27,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does TCL H27FMHD4XPC handle extreme weather or cold snaps?
Yes, TCL H27FMHD4XPC carries ENERGY STAR Cold Climate certification (96.3% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern TCL H27FMHD4XPC?
TCL H27FMHD4XPC specifies R-454B compliance (PD ID 4691437); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 2 certified SKUs in TCL H27FMHD4XPC reach 26.5 SEER2?
Peak 26.5 SEER2 represents the top tested AHRI pairing for TCL H27FMHD4XPC (PD ID 4691437); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to TCL H27FMHD4XPC?
TCL H27FMHD4XPC requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Clima Smart MU-CSU27HEI2NAM0T24-4PO.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.