SUPREME SUPMZ18R454 — Mini-Split Heat Pump Specifications
SUPREME SUPMZ18R454 (Mini-Split Heat Pump, PD ID 4717648) holds 1 ENERGY STAR certified SKU rated at 27.0 SEER2 — #361 of 2,096 (Top 21.9%, 98 tied), +1.90 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). SUPREME SUPMZ18R454 — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 27.0 SEER2 and Heating Rating set at 10.0 HSPF2.
- Max SEER2
- 27.0 SEER2
- Heating Rating
- 10.0 HSPF2
- Heating COP
- 2.0 COP
- Cohort Rank
- #361/2,096
- Verified Combos
- 1 SKU
- Sample PD ID
- 4717648
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | Peer range |
| 25.0 - 26.2 SEER2 | 785 | Peer range |
| 26.2 - 27.5 SEER2 | 272 | This series |
| 27.5 - 28.8 SEER2 | 150 | Peer range |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |
How does SUPREME SUPMZ18R454 rank across federal compliance and ENERGY STAR cohorts?
SUPREME SUPMZ18R454 ranks #361 of 2,096 (tied with 97 others at 27.0 SEER2, top 21.9%, more efficient than 78.1% of certified series) for Max SEER2 (+1.90 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (99.0% capacity retention at 5F) (1.7 nominal Tons at 20,000 BTU/h) charged with R-454B. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #361 of 2,096 (Top 21.9%, 98 tied) | +1.90 SEER2 vs 25.1 SEER2 category median |
| Heating HSPF2 vs Cohort | 10.0 HSPF2 | -0.50 HSPF2 vs 10.5 HSPF2 median |
| Peak 95F EER2 vs Cohort | 15.0 EER2 | +1.00 EER2 vs 14.0 EER2 median |
| 5F Cold-Weather Capacity Retention | 99.0% of 47F rating | 5F COP 2.0 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 27.0 SEER2 / 10.0 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 15.0 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (1947/2096 series in category) |
| 2026 Cleaner Refrigerant Rule | R-454B / R-32 READY | Listed refrigerant: R-454B; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does SUPREME SUPMZ18R454 require?
Annual cost outputs combine SUPREME SUPMZ18R454's 27.0 SEER2 rating and EIA national tariffs across single-family runtime hours.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 741 kWh/yr | $121/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 3,000 kWh/yr | $490/yr at US median |
| Combined Annual Electricity Cost | $611/yr | State range: $476 (NV) to $1,765 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 1,658 kWh/yr | $271/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to SUPREME SUPMZ18R454?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for SUPREME SUPMZ18R454 (PD ID 4717648).
| SUPMZ18R454 | Matched AHRI Coil | 20,000 BTU/h | 27.0 SEER2 / 10.0 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on SUPREME SUPMZ18R454, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across SUPREME SUPMZ18R454: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for SUPREME SUPMZ18R454 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- SUPREME SUPMZ18R454 uses A2L R-454B, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal SUPREME SUPMZ18R454 fit | Single-family replacement needing documented ENERGY STAR PD ID 4717648 with matching indoor air handler. |
| Skip SUPREME SUPMZ18R454 if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable mini-split heat pump models deliver similar efficiency?
Compare SUPREME SUPMZ18R454 against Clima Smart CSU06HEI2NAM0T24 and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does SUPREME SUPMZ18R454 compare with peer Mini-Split Heat Pump units?
SUPREME SUPMZ18R454 holds #361 of 2,096 (Top 21.9%, 98 tied) out of 2,096 verified mini-split heat pump models (+1.90 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 27.0 SEER2. Closest same-cohort alternatives include Clima Smart CSU06HEI2NAM0T24.
Where is SUPREME SUPMZ18R454 compliant for 2026 US installation?
SUPREME SUPMZ18R454: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does SUPREME SUPMZ18R454 model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, SUPREME SUPMZ18R454 runs 741 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does SUPREME SUPMZ18R454 cover?
SUPREME SUPMZ18R454 covers 20,000-20,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does SUPREME SUPMZ18R454 handle extreme weather or cold snaps?
Yes, SUPREME SUPMZ18R454 carries ENERGY STAR Cold Climate certification (99.0% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern SUPREME SUPMZ18R454?
SUPREME SUPMZ18R454 specifies R-454B compliance (PD ID 4717648); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in SUPREME SUPMZ18R454 reach 27.0 SEER2?
Peak 27.0 SEER2 represents the top tested AHRI pairing for SUPREME SUPMZ18R454 (PD ID 4717648); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to SUPREME SUPMZ18R454?
SUPREME SUPMZ18R454 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Clima Smart CSU06HEI2NAM0T24.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.