Star Air Kontrol SAK-18-24MS/220 — Mini-Split Heat Pump Specifications
Star Air Kontrol SAK-18-24MS/220 (Mini-Split Heat Pump, PD ID 3542721) holds 1 ENERGY STAR certified SKU rated at 23.7 SEER2 — #2,088 of 2,096 (9 tied at floor), -1.40 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). Star Air Kontrol SAK-18-24MS/220 — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 23.7 SEER2 and Heating Rating set at 10.3 HSPF2.
- Max SEER2
- 23.7 SEER2
- Heating Rating
- 10.3 HSPF2
- Heating COP
- 2.39 COP
- Cohort Rank
- #2,088/2,096
- Verified Combos
- 1 SKU
- Sample PD ID
- 3542721
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | This series |
| 25.0 - 26.2 SEER2 | 785 | Peer range |
| 26.2 - 27.5 SEER2 | 272 | Peer range |
| 27.5 - 28.8 SEER2 | 150 | Peer range |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |
How does Star Air Kontrol SAK-18-24MS/220 rank across federal compliance and ENERGY STAR cohorts?
Star Air Kontrol SAK-18-24MS/220 ties with 8 peers at 23.7 SEER2 (the cohort floor across 2,096 certified series) for Max SEER2 (-1.40 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (70.0% capacity retention at 5F) (1.5 nominal Tons at 18,000 BTU/h) charged with R-410A. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #2,088 of 2,096 (9 tied at floor) | -1.40 SEER2 vs 25.1 SEER2 category median |
| Heating HSPF2 vs Cohort | 10.3 HSPF2 | -0.20 HSPF2 vs 10.5 HSPF2 median |
| Peak 95F EER2 vs Cohort | 13.5 EER2 | -0.50 EER2 vs 14.0 EER2 median |
| 5F Cold-Weather Capacity Retention | 70.0% of 47F rating | 5F COP 2.39 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 23.7 SEER2 / 10.3 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 13.5 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (1947/2096 series in category) |
| 2026 Cleaner Refrigerant Rule | OLDER R-410A | Listed refrigerant: R-410A; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does Star Air Kontrol SAK-18-24MS/220 require?
Annual cost outputs combine Star Air Kontrol SAK-18-24MS/220's 23.7 SEER2 rating and EIA national tariffs across single-family runtime hours.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 759 kWh/yr | $124/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 2,913 kWh/yr | $476/yr at US median |
| Combined Annual Electricity Cost | $600/yr | State range: $467 (NV) to $1,732 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 1,587 kWh/yr | $259/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to Star Air Kontrol SAK-18-24MS/220?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Star Air Kontrol SAK-18-24MS/220 (PD ID 3542721).
| SAK-18-24MS/220 | SAK-18-24MS/220 | 18,000 BTU/h | 23.7 SEER2 / 10.3 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Star Air Kontrol SAK-18-24MS/220, review 2 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Star Air Kontrol SAK-18-24MS/220: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Star Air Kontrol SAK-18-24MS/220 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Star Air Kontrol SAK-18-24MS/220 fit | Single-family replacement needing documented ENERGY STAR PD ID 3542721 with matching indoor air handler. |
| Skip Star Air Kontrol SAK-18-24MS/220 if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable mini-split heat pump models deliver similar efficiency?
Compare Star Air Kontrol SAK-18-24MS/220 against ApooDr ASG24-18H1B and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Star Air Kontrol SAK-18-24MS/220 compare with peer Mini-Split Heat Pump units?
Star Air Kontrol SAK-18-24MS/220 holds #2,088 of 2,096 (9 tied at floor) out of 2,096 verified mini-split heat pump models (-1.40 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 23.7 SEER2. Closest same-cohort alternatives include ApooDr ASG24-18H1B.
Where is Star Air Kontrol SAK-18-24MS/220 compliant for 2026 US installation?
Star Air Kontrol SAK-18-24MS/220: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Star Air Kontrol SAK-18-24MS/220 model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Star Air Kontrol SAK-18-24MS/220 runs 759 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does Star Air Kontrol SAK-18-24MS/220 cover?
Star Air Kontrol SAK-18-24MS/220 covers 18,000-18,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Star Air Kontrol SAK-18-24MS/220 handle extreme weather or cold snaps?
Yes, Star Air Kontrol SAK-18-24MS/220 carries ENERGY STAR Cold Climate certification (70.0% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern Star Air Kontrol SAK-18-24MS/220?
Star Air Kontrol SAK-18-24MS/220 specifies R-410A compliance (PD ID 3542721); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in Star Air Kontrol SAK-18-24MS/220 reach 23.7 SEER2?
Peak 23.7 SEER2 represents the top tested AHRI pairing for Star Air Kontrol SAK-18-24MS/220 (PD ID 3542721); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Star Air Kontrol SAK-18-24MS/220?
Star Air Kontrol SAK-18-24MS/220 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include ApooDr ASG24-18H1B.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.