SLIMAIR SHC09AE2AG — Mini-Split Heat Pump Specifications
SLIMAIR SHC09AE2AG (Mini-Split Heat Pump, PD ID 4624005) holds 2 ENERGY STAR certified SKUs rated at 24.6 SEER2 — #1,391 of 2,096 (90 tied, beats 29.4% of peers), -0.50 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). SLIMAIR SHC09AE2AG — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 24.6 SEER2 and Heating Rating set at 13.0 HSPF2.
- Max SEER2
- 24.6 SEER2
- Heating Rating
- 13.0 HSPF2
- Heating COP
- 2.33 COP
- Cohort Rank
- #1,391/2,096
- Verified Combos
- 2 SKUs
- Sample PD ID
- 4624005
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | This series |
| 25.0 - 26.2 SEER2 | 785 | Peer range |
| 26.2 - 27.5 SEER2 | 272 | Peer range |
| 27.5 - 28.8 SEER2 | 150 | Peer range |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |
How does SLIMAIR SHC09AE2AG rank across federal compliance and ENERGY STAR cohorts?
SLIMAIR SHC09AE2AG ranks #1,391 of 2,096 (tied with 89 others at 24.6 SEER2, more efficient than 29.4% of certified series) for Max SEER2 (-0.50 SEER2 vs 25.1 SEER2 category median) across 2 certified SKU combinations. Rated for cold-climate output (82.0% capacity retention at 5F) (0.8 nominal Tons at 9,000 BTU/h) charged with R-454B. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #1,391 of 2,096 (90 tied, beats 29.4% of peers) | -0.50 SEER2 vs 25.1 SEER2 category median |
| Heating HSPF2 vs Cohort | 13.0 HSPF2 | +2.50 HSPF2 vs 10.5 HSPF2 median |
| Peak 95F EER2 vs Cohort | 14.7 EER2 | +0.70 EER2 vs 14.0 EER2 median |
| 5F Cold-Weather Capacity Retention | 82.0% of 47F rating | 5F COP 2.33 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 24.6 SEER2 / 13.0 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 14.7 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (1947/2096 series in category) |
| 2026 Cleaner Refrigerant Rule | R-454B / R-32 READY | Listed refrigerant: R-454B; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does SLIMAIR SHC09AE2AG require?
Modeled utility figures for SLIMAIR SHC09AE2AG (SLIMAIR) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max SEER2 ratings.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 366 kWh/yr | $60/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 2,308 kWh/yr | $377/yr at US median |
| Combined Annual Electricity Cost | $437/yr | State range: $340 (NV) to $1,262 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 1,955 kWh/yr | $319/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to SLIMAIR SHC09AE2AG?
Showing 2 certified indoor-outdoor coil combinations from 2 total AHRI matched records filed for SLIMAIR SHC09AE2AG (PD ID 4624005).
| SHC09AE2AG | SHMWS09AE2AG | 9,000 BTU/h | 24.6 SEER2 / 13.0 HSPF2 |
| SHC09AE2AG | SHM09AE2AG | 9,000 BTU/h | 24.6 SEER2 / 13.0 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on SLIMAIR SHC09AE2AG, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across SLIMAIR SHC09AE2AG: headline Max SEER2 reflects peak tested matches among 2 SKUs, not lower-rated sizes.
- Catalog specs for SLIMAIR SHC09AE2AG exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- SLIMAIR SHC09AE2AG uses A2L R-454B, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal SLIMAIR SHC09AE2AG fit | Single-family replacement needing documented ENERGY STAR PD ID 4624005 with matching indoor air handler. |
| Skip SLIMAIR SHC09AE2AG if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable mini-split heat pump models deliver similar efficiency?
Compare SLIMAIR SHC09AE2AG against 1HVAC ACIQ-09ZS-HP230C and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does SLIMAIR SHC09AE2AG compare with peer Mini-Split Heat Pump units?
SLIMAIR SHC09AE2AG holds #1,391 of 2,096 (90 tied, beats 29.4% of peers) out of 2,096 verified mini-split heat pump models (-0.50 SEER2 vs 25.1 SEER2 category median), spanning 2 certified SKUs up to 24.6 SEER2. Closest same-cohort alternatives include 1HVAC ACIQ-09ZS-HP230C.
Where is SLIMAIR SHC09AE2AG compliant for 2026 US installation?
SLIMAIR SHC09AE2AG: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does SLIMAIR SHC09AE2AG model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, SLIMAIR SHC09AE2AG runs 366 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does SLIMAIR SHC09AE2AG cover?
SLIMAIR SHC09AE2AG covers 9,000-9,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does SLIMAIR SHC09AE2AG handle extreme weather or cold snaps?
Yes, SLIMAIR SHC09AE2AG carries ENERGY STAR Cold Climate certification (82.0% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern SLIMAIR SHC09AE2AG?
SLIMAIR SHC09AE2AG specifies R-454B compliance (PD ID 4624005); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 2 certified SKUs in SLIMAIR SHC09AE2AG reach 24.6 SEER2?
Peak 24.6 SEER2 represents the top tested AHRI pairing for SLIMAIR SHC09AE2AG (PD ID 4624005); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to SLIMAIR SHC09AE2AG?
SLIMAIR SHC09AE2AG requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include 1HVAC ACIQ-09ZS-HP230C.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.