Samsung Mini-Split Heat Pumps — ENERGY STAR Certified Models

ThermalSpec indexes 17 Samsung mini-split heat pumps models spanning 9,000-24,000 BTU/h, anchored by AR09DXFAMWKX (26.0 SEER2) and AC018DXSCCG (23.8 SEER2). Samsung Mini-Split Heat Pumps — ENERGY STAR Certified Models benchmarks residential systems using Certified Models set at 17 and Rating Span set at 23.8 SEER2 - 26.0 SEER2. Values trace to primary federal, state, or OEM filings supporting Samsung Mini-Split Heat Pumps — ENERGY STAR Certified Models across single-family housing.

Certified Models
17
Rating Span
23.8 SEER2 - 26.0 SEER2
Capacity Range
9,000-24,000 BTU/h
AHRI Combinations
27
Cold Climate Units
15
Category Median
25.1 SEER2
Residential air handler cabinet with galvanized ductwork and brazed copper piping
Samsung Mini-Split Heat Pumps — ENERGY STAR Certified Models editorial reference. ThermalSpec Editorial Photography

How does Samsung's mini-split heat pumps portfolio cover capacity, refrigerants, and safety?

Samsung covers 9,000-24,000 BTU/h in mini-split heat pumps across 17 canonical models and 27 AHRI combinations, with 15 Cold Climate certified models and R-32. Ratings span 23.8 SEER2 up to 26.0 SEER2 (category median 25.1 SEER2, certified through 2026-04-17). CPSC records show 0 residential HVAC recall notices matching Samsung; check exact AHRI matched pairings on individual model sheets.

Showing 17 entries

Which verified records belong in Samsung Mini-Split Heat Pumps — ENERGY STAR Certified Models?

Compare all 17 verified entries below. Click any column header to sort numerically or alphabetically, then select any row for full benchmark citations.

All 17 ENERGY STAR Samsung Mini-Split Heat Pumps Models
Samsung AR09DXFAMWKX 25.0 SEER2 9.0 HSPF2 9,000 BTU/h 2
Samsung AR70H09CACWX 25.0 SEER2 10.5 HSPF2 9,000 BTU/h 2
Samsung AR70H09CAEBX 25.0 SEER2 10.5 HSPF2 9,000 BTU/h 2
Samsung MWLE009S6S-1P 25.0 SEER2 10.5 HSPF2 9,000 BTU/h 2
Samsung MWPE009S6S-1P 25.0 SEER2 10.5 HSPF2 9,000 BTU/h 2
Samsung AR12DXFAMWKX 24.0 SEER2 9.0 HSPF2 12,000 BTU/h 2
Samsung AR70H12CACWX 24.0 SEER2 10.5 HSPF2 12,000 BTU/h 2
Samsung AR70H12CAEBX 24.0 SEER2 10.5 HSPF2 12,000 BTU/h 2
Samsung MWLE012S6S-1P 24.0 SEER2 10.5 HSPF2 12,000 BTU/h 2
Samsung MWPE012S6S-1P 24.0 SEER2 10.5 HSPF2 12,000 BTU/h 2
Samsung AM024HCMDCG 26.0 SEER2 10.7 HSPF2 24,000 BTU/h 1
Samsung AR09DXDABWKX 25.0 SEER2 10.5 HSPF2 9,000 BTU/h 1
Samsung AR09DXDACWKX 25.0 SEER2 10.5 HSPF2 9,000 BTU/h 1
Samsung AR12DXDABWKX 24.0 SEER2 10.5 HSPF2 12,000 BTU/h 1
Samsung AR12DXDACWKX 24.0 SEER2 10.5 HSPF2 12,000 BTU/h 1
Samsung AC018DXADCG 23.8 SEER2 9.3 HSPF2 18,000 BTU/h 1
Samsung AC018DXSCCG 23.8 SEER2 9.6 HSPF2 18,000 BTU/h 1

Which top Samsung mini-split heat pumps anchor this lineup?

Select any of the 4 verified listings below to open detailed specifications, safety boundaries, and source links.

Samsung25.0 SEER2

Samsung AR09DXFAMWKX

9.0 HSPF2 | 9,000 BTU/h | 2 SKUs

Samsung25.0 SEER2

Samsung AR70H09CACWX

10.5 HSPF2 | 9,000 BTU/h | 2 SKUs

Samsung25.0 SEER2

Samsung AR70H09CAEBX

10.5 HSPF2 | 9,000 BTU/h | 2 SKUs

Samsung25.0 SEER2

Samsung MWLE009S6S-1P

10.5 HSPF2 | 9,000 BTU/h | 2 SKUs

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Samsung Mini-Split Heat Pumps, review 3 important real-world limits and verify local licensing and permit rules directly.

  • Cohort spread across Samsung: 23.8 SEER2 entry units differ substantially from flagship AR09DXFAMWKX (26.0 SEER2).
  • Verify indoor coil AHRI pairing on PD ID 3621246 and 3621190 before pulling state mechanical permits.
  • Equipment catalog metrics exclude ductwork upgrades, A2L leak sensors where applicable, and municipal inspection fees.
Homeowner ScenarioRecommended Verification Path
Best fit for SamsungHomes matched to 9,000-24,000 BTU/h seeking R-32 compliance and verified ENERGY STAR documentation.
Skip or verify further ifExisting ductwork pushes total static pressure above 0.50 in. w.c. or 3-phase commercial wiring is present.

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Samsung Peak

Which Samsung mini-split heat pumps model reaches the highest 26.0 SEER2 rating?

AR09DXFAMWKX tops Samsung's 17 ENERGY STAR mini-split heat pumps models at 26.0 SEER2 across 2 AHRI matches (PD ID 3621246).

Lineup Span

How broad is Samsung's mini-split heat pumps efficiency and BTU range?

Samsung spans 23.8 SEER2 (AC018DXSCCG) up to 26.0 SEER2 (AR09DXFAMWKX) across 9,000-24,000 BTU/h, compared with the 25.1 SEER2 category median.

AHRI Pairs

How many AHRI combinations support Samsung mini-split heat pumps?

Current ENERGY STAR datasets document 27 verified indoor-outdoor AHRI combinations distributed across 17 canonical Samsung models.

Cold / Fuel

What refrigerants or fuels power Samsung mini-split heat pumps?

Samsung mini-split heat pumps listings record R-32, with 15 Cold Climate certified models inside the mini-split heat pumps cohort.

DOE Regions

Where are Samsung mini-split heat pumps compliant under 2026 federal rules?

Models meeting 13.4 SEER2 qualify in the North; 14.3 SEER2 (plus 11.7 EER2 or 9.8 at 15.2+ SEER2) is needed for Southwest split cooling, while split heat pumps require 14.3 SEER2 / 7.5 HSPF2 nationwide.

CPSC Recalls

Are any CPSC safety recalls linked to Samsung residential HVAC products?

ThermalSpec counts 0 residential HVAC CPSC filings referencing Samsung; verify model serial prefixes at /recalls/ before installation or service.

25C Tax Credit

Do Samsung mini-split heat pumps receive federal Section 25C credits in 2026?

No — IRS Section 25C credits terminated December 31, 2025 ($0 federal tax credit for Samsung in 2026). Check state HOMES/HEAR and local utility ENERGY STAR rebates using PD ID 3621246.

Sizing Rule

How should homeowners select among Samsung's 17 mini-split heat pumps models?

Match Samsung model capacity (9,000-24,000 BTU/h) using an ACCA Manual J room-by-room heat load and <= 0.50 in. w.c. static pressure check rather than old unit tonnage.

Sources

Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)