Mitsubishi Electric MUFZ-KJ09NAHZ*** — Mini-Split Heat Pump Specifications
Mitsubishi Electric MUFZ-KJ09NAHZ*** (Mini-Split Heat Pump, PD ID 2415708) holds 3 ENERGY STAR certified SKUs rated at 28.7 SEER2 — #173 of 2,096 (Top 8.3%, 3 tied), +3.60 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). Mitsubishi Electric MUFZ-KJ09NAHZ*** — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 28.7 SEER2 and Heating Rating set at 11.3 HSPF2.
- Max SEER2
- 28.7 SEER2
- Heating Rating
- 11.3 HSPF2
- Cohort Rank
- #173/2,096
- Verified Combos
- 3 SKUs
- Sample PD ID
- 2415708
- Federal AC Minimum
- 13.4 - 14.3 SEER2
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | Peer range |
| 25.0 - 26.2 SEER2 | 785 | Peer range |
| 26.2 - 27.5 SEER2 | 272 | Peer range |
| 27.5 - 28.8 SEER2 | 150 | This series |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |
How does Mitsubishi Electric MUFZ-KJ09NAHZ*** rank across federal compliance and ENERGY STAR cohorts?
Mitsubishi Electric MUFZ-KJ09NAHZ*** ranks #173 of 2,096 (tied with 2 others at 28.7 SEER2, top 8.3%, more efficient than 91.7% of certified series) for Max SEER2 (+3.60 SEER2 vs 25.1 SEER2 category median) across 3 certified SKU combinations. Built with Continuously variable modulation (0.8 nominal Tons at 9,000 BTU/h) charged with R-410A. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #173 of 2,096 (Top 8.3%, 3 tied) | +3.60 SEER2 vs 25.1 SEER2 category median |
| Heating HSPF2 vs Cohort | 11.3 HSPF2 | +0.80 HSPF2 vs 10.5 HSPF2 median |
| Peak 95F EER2 vs Cohort | 15.8 EER2 | +1.80 EER2 vs 14.0 EER2 median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 28.7 SEER2 / 11.3 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 15.8 EER2 |
| ENERGY STAR Cold Climate Spec | STANDARD CLIMATE | Designed for standard/mixed heating zones |
| 2026 Cleaner Refrigerant Rule | OLDER R-410A | Listed refrigerant: R-410A; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does Mitsubishi Electric MUFZ-KJ09NAHZ*** require?
Modeled utility figures for Mitsubishi Electric MUFZ-KJ09NAHZ*** (Mitsubishi Electric) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max SEER2 ratings.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 314 kWh/yr | $51/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 2,655 kWh/yr | $434/yr at US median |
| Combined Annual Electricity Cost | $485/yr | State range: $378 (NV) to $1,401 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 1,660 kWh/yr | $271/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to Mitsubishi Electric MUFZ-KJ09NAHZ***?
Showing 3 certified indoor-outdoor coil combinations from 3 total AHRI matched records filed for Mitsubishi Electric MUFZ-KJ09NAHZ*** (PD ID 2415708).
| MUFZ-KJ09NAHZ*** | MFZ-KJ09NA*** | 9,000 BTU/h | 28.7 SEER2 / 11.3 HSPF2 |
| MUFZ-KJ09NAHZ*** | NAXFKS09A112A* | 9,000 BTU/h | 28.7 SEER2 / 11.3 HSPF2 |
| MUFZ-KJ09NAHZ*** | NTXFKS09A112A* | 9,000 BTU/h | 28.7 SEER2 / 11.3 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Mitsubishi Electric MUFZ-KJ09NAHZ***, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Mitsubishi Electric MUFZ-KJ09NAHZ***: headline Max SEER2 reflects peak tested matches among 3 SKUs, not lower-rated sizes.
- Catalog specs for Mitsubishi Electric MUFZ-KJ09NAHZ*** exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- Mitsubishi Electric MUFZ-KJ09NAHZ*** lacks ENERGY STAR Cold Climate 5F designation, so electric heat strips or dual-fuel backup matter in Zones 5-8.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Mitsubishi Electric MUFZ-KJ09NAHZ*** fit | Single-family replacement needing documented ENERGY STAR PD ID 2415708 with matching indoor air handler. |
| Skip Mitsubishi Electric MUFZ-KJ09NAHZ*** if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable mini-split heat pump models deliver similar efficiency?
Compare Mitsubishi Electric MUFZ-KJ09NAHZ*** against Trane / Mitsubishi Electric NTXSPF09A112A* and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Mitsubishi Electric MUFZ-KJ09NAHZ*** compare with peer Mini-Split Heat Pump units?
Mitsubishi Electric MUFZ-KJ09NAHZ*** holds #173 of 2,096 (Top 8.3%, 3 tied) out of 2,096 verified mini-split heat pump models (+3.60 SEER2 vs 25.1 SEER2 category median), spanning 3 certified SKUs up to 28.7 SEER2. Closest same-cohort alternatives include Trane / Mitsubishi Electric NTXSPF09A112A*.
Where is Mitsubishi Electric MUFZ-KJ09NAHZ*** compliant for 2026 US installation?
Mitsubishi Electric MUFZ-KJ09NAHZ***: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Mitsubishi Electric MUFZ-KJ09NAHZ*** model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Mitsubishi Electric MUFZ-KJ09NAHZ*** runs 314 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does Mitsubishi Electric MUFZ-KJ09NAHZ*** cover?
Mitsubishi Electric MUFZ-KJ09NAHZ*** covers 9,000-9,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Mitsubishi Electric MUFZ-KJ09NAHZ*** handle extreme weather or cold snaps?
Mitsubishi Electric MUFZ-KJ09NAHZ*** is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.
What refrigerant class and 2026 tax credit rules govern Mitsubishi Electric MUFZ-KJ09NAHZ***?
Mitsubishi Electric MUFZ-KJ09NAHZ*** specifies R-410A compliance (PD ID 2415708); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 3 certified SKUs in Mitsubishi Electric MUFZ-KJ09NAHZ*** reach 28.7 SEER2?
Peak 28.7 SEER2 represents the top tested AHRI pairing for Mitsubishi Electric MUFZ-KJ09NAHZ*** (PD ID 2415708); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Mitsubishi Electric MUFZ-KJ09NAHZ***?
Mitsubishi Electric MUFZ-KJ09NAHZ*** requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Trane / Mitsubishi Electric NTXSPF09A112A*.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages