Innovair MOS18H2BM0A — Mini-Split Heat Pump Specifications
Innovair MOS18H2BM0A (Mini-Split Heat Pump, PD ID 4015745) holds 1 ENERGY STAR certified SKU rated at 23.8 SEER2 — #2,071 of 2,096 (17 tied, beats 0.4% of peers), -1.30 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). Innovair MOS18H2BM0A — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 23.8 SEER2 and Heating Rating set at 13.5 HSPF2.
- Max SEER2
- 23.8 SEER2
- Heating Rating
- 13.5 HSPF2
- Heating COP
- 2.16 COP
- Cohort Rank
- #2,071/2,096
- Verified Combos
- 1 SKU
- Sample PD ID
- 4015745
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | This series |
| 25.0 - 26.2 SEER2 | 785 | Peer range |
| 26.2 - 27.5 SEER2 | 272 | Peer range |
| 27.5 - 28.8 SEER2 | 150 | Peer range |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |
How does Innovair MOS18H2BM0A rank across federal compliance and ENERGY STAR cohorts?
Innovair MOS18H2BM0A ranks #2,071 of 2,096 (tied with 16 others at 23.8 SEER2, more efficient than 0.4% of certified series) for Max SEER2 (-1.30 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (77.1% capacity retention at 5F) (1.3 nominal Tons at 16,000 BTU/h) charged with R-454B. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #2,071 of 2,096 (17 tied, beats 0.4% of peers) | -1.30 SEER2 vs 25.1 SEER2 category median |
| Heating HSPF2 vs Cohort | 13.5 HSPF2 | +3.00 HSPF2 vs 10.5 HSPF2 median |
| Peak 95F EER2 vs Cohort | 12.5 EER2 | -1.50 EER2 vs 14.0 EER2 median |
| 5F Cold-Weather Capacity Retention | 77.1% of 47F rating | 5F COP 2.16 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 23.8 SEER2 / 13.5 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 12.5 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (1947/2096 series in category) |
| 2026 Cleaner Refrigerant Rule | R-454B / R-32 READY | Listed refrigerant: R-454B; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does Innovair MOS18H2BM0A require?
Modeled utility figures for Innovair MOS18H2BM0A (Innovair) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max SEER2 ratings.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 672 kWh/yr | $110/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 2,222 kWh/yr | $363/yr at US median |
| Combined Annual Electricity Cost | $473/yr | State range: $368 (NV) to $1,365 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 2,225 kWh/yr | $363/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to Innovair MOS18H2BM0A?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Innovair MOS18H2BM0A (PD ID 4015745).
| MOS18H2BM0A | MCW16H2BHRA | 16,000 BTU/h | 23.8 SEER2 / 13.5 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Innovair MOS18H2BM0A, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Innovair MOS18H2BM0A: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Innovair MOS18H2BM0A exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- Innovair MOS18H2BM0A uses A2L R-454B, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Innovair MOS18H2BM0A fit | Single-family replacement needing documented ENERGY STAR PD ID 4015745 with matching indoor air handler. |
| Skip Innovair MOS18H2BM0A if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable mini-split heat pump models deliver similar efficiency?
Compare Innovair MOS18H2BM0A against AC PRO MHPC-H-018BSB and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Innovair MOS18H2BM0A compare with peer Mini-Split Heat Pump units?
Innovair MOS18H2BM0A holds #2,071 of 2,096 (17 tied, beats 0.4% of peers) out of 2,096 verified mini-split heat pump models (-1.30 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 23.8 SEER2. Closest same-cohort alternatives include AC PRO MHPC-H-018BSB.
Where is Innovair MOS18H2BM0A compliant for 2026 US installation?
Innovair MOS18H2BM0A: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Innovair MOS18H2BM0A model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Innovair MOS18H2BM0A runs 672 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does Innovair MOS18H2BM0A cover?
Innovair MOS18H2BM0A covers 16,000-16,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Innovair MOS18H2BM0A handle extreme weather or cold snaps?
Yes, Innovair MOS18H2BM0A carries ENERGY STAR Cold Climate certification (77.1% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern Innovair MOS18H2BM0A?
Innovair MOS18H2BM0A specifies R-454B compliance (PD ID 4015745); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in Innovair MOS18H2BM0A reach 23.8 SEER2?
Peak 23.8 SEER2 represents the top tested AHRI pairing for Innovair MOS18H2BM0A (PD ID 4015745); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Innovair MOS18H2BM0A?
Innovair MOS18H2BM0A requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include AC PRO MHPC-H-018BSB.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.