InfinityLiving EZ-18Z-M2B — Mini-Split Heat Pump Specifications
InfinityLiving EZ-18Z-M2B (Mini-Split Heat Pump, PD ID 3997808) holds 1 ENERGY STAR certified SKU rated at 23.9 SEER2 — #2,010 of 2,096 (61 tied, beats 1.2% of peers), -1.20 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). InfinityLiving EZ-18Z-M2B — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 23.9 SEER2 and Heating Rating set at 10.0 HSPF2.
- Max SEER2
- 23.9 SEER2
- Heating Rating
- 10.0 HSPF2
- Heating COP
- 2.3 COP
- Cohort Rank
- #2,010/2,096
- Verified Combos
- 1 SKU
- Sample PD ID
- 3997808
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | This series |
| 25.0 - 26.2 SEER2 | 785 | Peer range |
| 26.2 - 27.5 SEER2 | 272 | Peer range |
| 27.5 - 28.8 SEER2 | 150 | Peer range |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |
How does InfinityLiving EZ-18Z-M2B rank across federal compliance and ENERGY STAR cohorts?
InfinityLiving EZ-18Z-M2B ranks #2,010 of 2,096 (tied with 60 others at 23.9 SEER2, more efficient than 1.2% of certified series) for Max SEER2 (-1.20 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (73.9% capacity retention at 5F) (1.5 nominal Tons at 18,000 BTU/h) charged with R-454B. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #2,010 of 2,096 (61 tied, beats 1.2% of peers) | -1.20 SEER2 vs 25.1 SEER2 category median |
| Heating HSPF2 vs Cohort | 10.0 HSPF2 | -0.50 HSPF2 vs 10.5 HSPF2 median |
| Peak 95F EER2 vs Cohort | 13.0 EER2 | -1.00 EER2 vs 14.0 EER2 median |
| 5F Cold-Weather Capacity Retention | 73.9% of 47F rating | 5F COP 2.3 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 23.9 SEER2 / 10.0 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 13.0 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (1947/2096 series in category) |
| 2026 Cleaner Refrigerant Rule | R-454B / R-32 READY | Listed refrigerant: R-454B; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does InfinityLiving EZ-18Z-M2B require?
Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, InfinityLiving EZ-18Z-M2B estimates reflect 1 certified SKU combination tested under PD ID 3997808.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 753 kWh/yr | $123/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 3,000 kWh/yr | $490/yr at US median |
| Combined Annual Electricity Cost | $613/yr | State range: $477 (NV) to $1,771 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 1,506 kWh/yr | $246/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to InfinityLiving EZ-18Z-M2B?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for InfinityLiving EZ-18Z-M2B (PD ID 3997808).
| EZ-18Z-M2B | Matched AHRI Coil | 18,000 BTU/h | 23.9 SEER2 / 10.0 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on InfinityLiving EZ-18Z-M2B, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across InfinityLiving EZ-18Z-M2B: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for InfinityLiving EZ-18Z-M2B exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- InfinityLiving EZ-18Z-M2B uses A2L R-454B, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal InfinityLiving EZ-18Z-M2B fit | Single-family replacement needing documented ENERGY STAR PD ID 3997808 with matching indoor air handler. |
| Skip InfinityLiving EZ-18Z-M2B if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable mini-split heat pump models deliver similar efficiency?
Compare InfinityLiving EZ-18Z-M2B against 1HVAC EZ-18Z-M2B and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does InfinityLiving EZ-18Z-M2B compare with peer Mini-Split Heat Pump units?
InfinityLiving EZ-18Z-M2B holds #2,010 of 2,096 (61 tied, beats 1.2% of peers) out of 2,096 verified mini-split heat pump models (-1.20 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 23.9 SEER2. Closest same-cohort alternatives include 1HVAC EZ-18Z-M2B.
Where is InfinityLiving EZ-18Z-M2B compliant for 2026 US installation?
InfinityLiving EZ-18Z-M2B: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does InfinityLiving EZ-18Z-M2B model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, InfinityLiving EZ-18Z-M2B runs 753 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does InfinityLiving EZ-18Z-M2B cover?
InfinityLiving EZ-18Z-M2B covers 18,000-18,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does InfinityLiving EZ-18Z-M2B handle extreme weather or cold snaps?
Yes, InfinityLiving EZ-18Z-M2B carries ENERGY STAR Cold Climate certification (73.9% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern InfinityLiving EZ-18Z-M2B?
InfinityLiving EZ-18Z-M2B specifies R-454B compliance (PD ID 3997808); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in InfinityLiving EZ-18Z-M2B reach 23.9 SEER2?
Peak 23.9 SEER2 represents the top tested AHRI pairing for InfinityLiving EZ-18Z-M2B (PD ID 3997808); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to InfinityLiving EZ-18Z-M2B?
InfinityLiving EZ-18Z-M2B requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include 1HVAC EZ-18Z-M2B.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)