Skip to main content
Mini-Split Heat Pump · Hisense · 1 ENERGY STAR Combinations

Hisense AS-15UW3TBW00 — Mini-Split Heat Pump Specifications

Hisense AS-15UW3TBW00 (Mini-Split Heat Pump, PD ID 3999876) holds 1 ENERGY STAR certified SKU rated at 25.6 SEER2 — #737 of 2,096 (Top 36.6%, 32 tied), +0.50 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). Hisense AS-15UW3TBW00 — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 25.6 SEER2 and Heating Rating set at 11.1 HSPF2.

Max SEER2
25.6 SEER2
Heating Rating
11.1 HSPF2
Heating COP
2.25 COP
Cohort Rank
#737/2,096
Verified Combos
1 SKU
Sample PD ID
3999876
Mini-Split Heat Pump Efficiency Spread across 2096 certified series (23.7 to 35.1 SEER2)
Hisense AS-15UW3TBW00 Mini-Split Heat Pump Efficiency Spread Distribution Distribution of 2096 certified series from 23.7 to 35.1 SEER2. Hisense AS-15UW3TBW00 sits at 25.6 SEER2; typical midpoint is 25.1 SEER2. 717 23.7 785 25.0 272 26.2 150 27.5 86 28.8 1 30.0 28 31.3 38 32.6 19 33.8 Median 25.1 SEER2 This model: 25.6 SEER2 (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
23.7 - 25.0 SEER2717Peer range
25.0 - 26.2 SEER2785This series
26.2 - 27.5 SEER2272Peer range
27.5 - 28.8 SEER2150Peer range
28.8 - 30.0 SEER286Peer range
30.0 - 31.3 SEER21Peer range
31.3 - 32.6 SEER228Peer range
32.6 - 33.8 SEER238Peer range
33.8 - 35.1 SEER219Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
Hisense AS-15UW3TBW00 residential equipment inspection. ThermalSpec Editorial Photography

How does Hisense AS-15UW3TBW00 rank across federal compliance and ENERGY STAR cohorts?

Hisense AS-15UW3TBW00 ranks #737 of 2,096 (tied with 31 others at 25.6 SEER2, top 36.6%, more efficient than 63.4% of certified series) for Max SEER2 (+0.50 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (80.3% capacity retention at 5F) (1.2 nominal Tons at 15,000 BTU/h) charged with R-454B. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.

Hisense AS-15UW3TBW00 Cohort Metrics vs. Mini-Split Heat Pump Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max SEER2) #737 of 2,096 (Top 36.6%, 32 tied) +0.50 SEER2 vs 25.1 SEER2 category median
Heating HSPF2 vs Cohort 11.1 HSPF2 +0.60 HSPF2 vs 10.5 HSPF2 median
Peak 95F EER2 vs Cohort 13.65 EER2 -0.35 EER2 vs 14.0 EER2 median
5F Cold-Weather Capacity Retention 80.3% of 47F rating 5F COP 2.25
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Federal North & SE Heat Pump Minimum PASS Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 25.6 SEER2 / 11.1 HSPF2
Southwest Peak-Heat Criterion (AZ/CA/NM/NV) PASS Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 13.65 EER2
ENERGY STAR Cold Climate Spec CERTIFIED Cold Climate verified (1947/2096 series in category)
2026 Cleaner Refrigerant Rule R-454B / R-32 READY Listed refrigerant: R-454B; newer R-454B/R-32 splits include indoor leak sensors

How much annual energy and operating cost does Hisense AS-15UW3TBW00 require?

Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, Hisense AS-15UW3TBW00 estimates reflect 1 certified SKU combination tested under PD ID 3999876.

Cool_kWh = (15,000 BTU/h * 1,000 hrs / 25.6 SEER2) / 1,000 | Heat_kWh = 30,000 kBTU / 11.1 HSPF2

Assumes 1,000 cooling hrs + 30 MMBtu heating at US 51-state median 16.33 c/kWh (range 12.72 c NV to 47.18 c HI)

Operating BasisEstimated ValueSource Basis
Estimated Annual Cooling Energy586 kWh/yr$96/yr at US median
Estimated Annual Heating Energy (30 MMBtu)2,703 kWh/yr$441/yr at US median
Combined Annual Electricity Cost$537/yrState range: $418 (NV) to $1,552 (HI)
Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor1,760 kWh/yr$287/yr saved
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to Hisense AS-15UW3TBW00?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Hisense AS-15UW3TBW00 (PD ID 3999876).

AS-15UW3TBW00 AS-15UW3TBW**00 15,000 BTU/h 25.6 SEER2 / 11.1 HSPF2

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Hisense AS-15UW3TBW00, review 3 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Hisense AS-15UW3TBW00: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for Hisense AS-15UW3TBW00 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
  • Hisense AS-15UW3TBW00 uses A2L R-454B, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
Homeowner ScenarioRecommended Verification Path
Ideal Hisense AS-15UW3TBW00 fitSingle-family replacement needing documented ENERGY STAR PD ID 3999876 with matching indoor air handler.
Skip Hisense AS-15UW3TBW00 ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable mini-split heat pump models deliver similar efficiency?

Compare Hisense AS-15UW3TBW00 against Gridless GRID15OHHV and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.

Gridless GRID15OHHV

25.6 SEER2 · 11.1 HSPF2 · 15,000 BTU/h

HAXXAIR HVHZ-15A2U

25.6 SEER2 · 11.1 HSPF2 · 15,000 BTU/h

Zephyr ZE-15UB32O

25.6 SEER2 · 11.1 HSPF2 · 15,000 BTU/h

AI AIR CONDITIONING AO35-18N2-M1H

25.6 SEER2 · 16.2 HSPF2 · 18,000 BTU/h

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Hisense AS-15UW3TBW00 compare with peer Mini-Split Heat Pump units?

Hisense AS-15UW3TBW00 holds #737 of 2,096 (Top 36.6%, 32 tied) out of 2,096 verified mini-split heat pump models (+0.50 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 25.6 SEER2. Closest same-cohort alternatives include Gridless GRID15OHHV.

DOE Regions

Where is Hisense AS-15UW3TBW00 compliant for 2026 US installation?

Hisense AS-15UW3TBW00: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Hisense AS-15UW3TBW00 model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Hisense AS-15UW3TBW00 runs 586 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Hisense AS-15UW3TBW00 cover?

Hisense AS-15UW3TBW00 covers 15,000-15,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Hisense AS-15UW3TBW00 handle extreme weather or cold snaps?

Yes, Hisense AS-15UW3TBW00 carries ENERGY STAR Cold Climate certification (80.3% capacity retention at 5 F).

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Hisense AS-15UW3TBW00?

Hisense AS-15UW3TBW00 specifies R-454B compliance (PD ID 3999876); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in Hisense AS-15UW3TBW00 reach 25.6 SEER2?

Peak 25.6 SEER2 represents the top tested AHRI pairing for Hisense AS-15UW3TBW00 (PD ID 3999876); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Hisense AS-15UW3TBW00?

Hisense AS-15UW3TBW00 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Gridless GRID15OHHV.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros