GREE GS24HP230V1RYO — Mini-Split Heat Pump Specifications
GREE GS24HP230V1RYO (Mini-Split Heat Pump, PD ID 4610404) holds 1 ENERGY STAR certified SKU rated at 27.0 SEER2 — #361 of 2,096 (Top 21.9%, 98 tied), +1.90 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). GREE GS24HP230V1RYO — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 27.0 SEER2 and Heating Rating set at 10.0 HSPF2.
- Max SEER2
- 27.0 SEER2
- Heating Rating
- 10.0 HSPF2
- Heating COP
- 1.8 COP
- Cohort Rank
- #361/2,096
- Verified Combos
- 1 SKU
- Sample PD ID
- 4610404
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | Peer range |
| 25.0 - 26.2 SEER2 | 785 | Peer range |
| 26.2 - 27.5 SEER2 | 272 | This series |
| 27.5 - 28.8 SEER2 | 150 | Peer range |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |
How does GREE GS24HP230V1RYO rank across federal compliance and ENERGY STAR cohorts?
GREE GS24HP230V1RYO ranks #361 of 2,096 (tied with 97 others at 27.0 SEER2, top 21.9%, more efficient than 78.1% of certified series) for Max SEER2 (+1.90 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (100.0% capacity retention at 5F) (1.8 nominal Tons at 22,000 BTU/h) charged with R-32. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #361 of 2,096 (Top 21.9%, 98 tied) | +1.90 SEER2 vs 25.1 SEER2 category median |
| Heating HSPF2 vs Cohort | 10.0 HSPF2 | -0.50 HSPF2 vs 10.5 HSPF2 median |
| Peak 95F EER2 vs Cohort | 13.95 EER2 | -0.05 EER2 vs 14.0 EER2 median |
| 5F Cold-Weather Capacity Retention | 100.0% of 47F rating | 5F COP 1.8 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 27.0 SEER2 / 10.0 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 13.95 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (1947/2096 series in category) |
| 2026 Cleaner Refrigerant Rule | R-454B / R-32 READY | Listed refrigerant: R-32; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does GREE GS24HP230V1RYO require?
Annual cost outputs combine GREE GS24HP230V1RYO's 27.0 SEER2 rating and EIA national tariffs across single-family runtime hours.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 815 kWh/yr | $133/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 3,000 kWh/yr | $490/yr at US median |
| Combined Annual Electricity Cost | $623/yr | State range: $485 (NV) to $1,800 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 1,723 kWh/yr | $281/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to GREE GS24HP230V1RYO?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for GREE GS24HP230V1RYO (PD ID 4610404).
| GS24HP230V1RYO | GS24HP230V1RYI | 22,000 BTU/h | 27.0 SEER2 / 10.0 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on GREE GS24HP230V1RYO, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across GREE GS24HP230V1RYO: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for GREE GS24HP230V1RYO exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- GREE GS24HP230V1RYO uses A2L R-32, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal GREE GS24HP230V1RYO fit | Single-family replacement needing documented ENERGY STAR PD ID 4610404 with matching indoor air handler. |
| Skip GREE GS24HP230V1RYO if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable mini-split heat pump models deliver similar efficiency?
Compare GREE GS24HP230V1RYO against BLUERIDGE BXS6Z24UC0 and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does GREE GS24HP230V1RYO compare with peer Mini-Split Heat Pump units?
GREE GS24HP230V1RYO holds #361 of 2,096 (Top 21.9%, 98 tied) out of 2,096 verified mini-split heat pump models (+1.90 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 27.0 SEER2. Closest same-cohort alternatives include BLUERIDGE BXS6Z24UC0.
Where is GREE GS24HP230V1RYO compliant for 2026 US installation?
GREE GS24HP230V1RYO: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does GREE GS24HP230V1RYO model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, GREE GS24HP230V1RYO runs 815 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does GREE GS24HP230V1RYO cover?
GREE GS24HP230V1RYO covers 22,000-22,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does GREE GS24HP230V1RYO handle extreme weather or cold snaps?
Yes, GREE GS24HP230V1RYO carries ENERGY STAR Cold Climate certification (100.0% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern GREE GS24HP230V1RYO?
GREE GS24HP230V1RYO specifies R-32 compliance (PD ID 4610404); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in GREE GS24HP230V1RYO reach 27.0 SEER2?
Peak 27.0 SEER2 represents the top tested AHRI pairing for GREE GS24HP230V1RYO (PD ID 4610404); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to GREE GS24HP230V1RYO?
GREE GS24HP230V1RYO requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include BLUERIDGE BXS6Z24UC0.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.