Goodman MSH093G22MCAA — Mini-Split Heat Pump Specifications
Goodman MSH093G22MCAA (Mini-Split Heat Pump, PD ID 3423467) holds 1 ENERGY STAR certified SKU rated at 26.4 SEER2 — #543 of 2,096 (Top 26.8%, 19 tied), +1.30 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). Goodman MSH093G22MCAA — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 26.4 SEER2 and Heating Rating set at 11.6 HSPF2.
- Max SEER2
- 26.4 SEER2
- Heating Rating
- 11.6 HSPF2
- Heating COP
- 1.85 COP
- Cohort Rank
- #543/2,096
- Verified Combos
- 1 SKU
- Sample PD ID
- 3423467
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | Peer range |
| 25.0 - 26.2 SEER2 | 785 | Peer range |
| 26.2 - 27.5 SEER2 | 272 | This series |
| 27.5 - 28.8 SEER2 | 150 | Peer range |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |
How does Goodman MSH093G22MCAA rank across federal compliance and ENERGY STAR cohorts?
Goodman MSH093G22MCAA ranks #543 of 2,096 (tied with 18 others at 26.4 SEER2, top 26.8%, more efficient than 73.2% of certified series) for Max SEER2 (+1.30 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (91.7% capacity retention at 5F) (0.8 nominal Tons at 9,000 BTU/h) charged with R-410A. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #543 of 2,096 (Top 26.8%, 19 tied) | +1.30 SEER2 vs 25.1 SEER2 category median |
| Heating HSPF2 vs Cohort | 11.6 HSPF2 | +1.10 HSPF2 vs 10.5 HSPF2 median |
| Peak 95F EER2 vs Cohort | 15.8 EER2 | +1.80 EER2 vs 14.0 EER2 median |
| 5F Cold-Weather Capacity Retention | 91.7% of 47F rating | 5F COP 1.85 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 26.4 SEER2 / 11.6 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 15.8 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (1947/2096 series in category) |
| 2026 Cleaner Refrigerant Rule | OLDER R-410A | Listed refrigerant: R-410A; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does Goodman MSH093G22MCAA require?
Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, Goodman MSH093G22MCAA estimates reflect 1 certified SKU combination tested under PD ID 3423467.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 341 kWh/yr | $56/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 2,586 kWh/yr | $422/yr at US median |
| Combined Annual Electricity Cost | $478/yr | State range: $372 (NV) to $1,381 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 1,702 kWh/yr | $278/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to Goodman MSH093G22MCAA?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Goodman MSH093G22MCAA (PD ID 3423467).
| MSH093G22MCAA | MSH093G22AXAA | 9,000 BTU/h | 26.4 SEER2 / 11.6 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Goodman MSH093G22MCAA, review 2 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Goodman MSH093G22MCAA: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Goodman MSH093G22MCAA exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Goodman MSH093G22MCAA fit | Single-family replacement needing documented ENERGY STAR PD ID 3423467 with matching indoor air handler. |
| Skip Goodman MSH093G22MCAA if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable mini-split heat pump models deliver similar efficiency?
Compare Goodman MSH093G22MCAA against AI AIR CONDITIONING AO25-09N1-M1H and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Goodman MSH093G22MCAA compare with peer Mini-Split Heat Pump units?
Goodman MSH093G22MCAA holds #543 of 2,096 (Top 26.8%, 19 tied) out of 2,096 verified mini-split heat pump models (+1.30 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 26.4 SEER2. Closest same-cohort alternatives include AI AIR CONDITIONING AO25-09N1-M1H.
Where is Goodman MSH093G22MCAA compliant for 2026 US installation?
Goodman MSH093G22MCAA: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Goodman MSH093G22MCAA model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Goodman MSH093G22MCAA runs 341 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does Goodman MSH093G22MCAA cover?
Goodman MSH093G22MCAA covers 9,000-9,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Goodman MSH093G22MCAA handle extreme weather or cold snaps?
Yes, Goodman MSH093G22MCAA carries ENERGY STAR Cold Climate certification (91.7% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern Goodman MSH093G22MCAA?
Goodman MSH093G22MCAA specifies R-410A compliance (PD ID 3423467); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in Goodman MSH093G22MCAA reach 26.4 SEER2?
Peak 26.4 SEER2 represents the top tested AHRI pairing for Goodman MSH093G22MCAA (PD ID 3423467); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Goodman MSH093G22MCAA?
Goodman MSH093G22MCAA requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include AI AIR CONDITIONING AO25-09N1-M1H.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.