Goodman MSH093E23MCAA — Mini-Split Heat Pump Specifications
Goodman MSH093E23MCAA (Mini-Split Heat Pump, PD ID 3999935) holds 1 ENERGY STAR certified SKU rated at 25.0 SEER2 — #1,069 of 2,096 (311 tied, beats 34.2% of peers), -0.10 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). Goodman MSH093E23MCAA — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 25.0 SEER2 and Heating Rating set at 11.0 HSPF2.
- Max SEER2
- 25.0 SEER2
- Heating Rating
- 11.0 HSPF2
- Heating COP
- 1.59 COP
- Cohort Rank
- #1,069/2,096
- Verified Combos
- 1 SKU
- Sample PD ID
- 3999935
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | Peer range |
| 25.0 - 26.2 SEER2 | 785 | This series |
| 26.2 - 27.5 SEER2 | 272 | Peer range |
| 27.5 - 28.8 SEER2 | 150 | Peer range |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |
How does Goodman MSH093E23MCAA rank across federal compliance and ENERGY STAR cohorts?
Goodman MSH093E23MCAA ranks #1,069 of 2,096 (tied with 310 others at 25.0 SEER2, more efficient than 34.2% of certified series) for Max SEER2 (-0.10 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Built with Continuously variable modulation (0.8 nominal Tons at 9,000 BTU/h) charged with R-410A. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #1,069 of 2,096 (311 tied, beats 34.2% of peers) | -0.10 SEER2 vs 25.1 SEER2 category median |
| Heating HSPF2 vs Cohort | 11.0 HSPF2 | +0.50 HSPF2 vs 10.5 HSPF2 median |
| Peak 95F EER2 vs Cohort | 15.6 EER2 | +1.60 EER2 vs 14.0 EER2 median |
| 5F Cold-Weather Capacity Retention | 85.2% of 47F rating | 5F COP 1.59 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 25.0 SEER2 / 11.0 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 15.6 EER2 |
| ENERGY STAR Cold Climate Spec | STANDARD CLIMATE | Designed for standard/mixed heating zones |
| 2026 Cleaner Refrigerant Rule | OLDER R-410A | Listed refrigerant: R-410A; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does Goodman MSH093E23MCAA require?
Annual cost outputs combine Goodman MSH093E23MCAA's 25.0 SEER2 rating and EIA national tariffs across single-family runtime hours.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 360 kWh/yr | $59/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 2,727 kWh/yr | $445/yr at US median |
| Combined Annual Electricity Cost | $504/yr | State range: $393 (NV) to $1,456 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 1,542 kWh/yr | $252/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to Goodman MSH093E23MCAA?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Goodman MSH093E23MCAA (PD ID 3999935).
| MSH093E23MCAA | MSH093E23AXAA | 9,000 BTU/h | 25.0 SEER2 / 11.0 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Goodman MSH093E23MCAA, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Goodman MSH093E23MCAA: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Goodman MSH093E23MCAA exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- Goodman MSH093E23MCAA lacks ENERGY STAR Cold Climate 5F designation, so electric heat strips or dual-fuel backup matter in Zones 5-8.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Goodman MSH093E23MCAA fit | Single-family replacement needing documented ENERGY STAR PD ID 3999935 with matching indoor air handler. |
| Skip Goodman MSH093E23MCAA if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable mini-split heat pump models deliver similar efficiency?
Compare Goodman MSH093E23MCAA against ApooDr ASG24-09H1B and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Goodman MSH093E23MCAA compare with peer Mini-Split Heat Pump units?
Goodman MSH093E23MCAA holds #1,069 of 2,096 (311 tied, beats 34.2% of peers) out of 2,096 verified mini-split heat pump models (-0.10 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 25.0 SEER2. Closest same-cohort alternatives include ApooDr ASG24-09H1B.
Where is Goodman MSH093E23MCAA compliant for 2026 US installation?
Goodman MSH093E23MCAA: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Goodman MSH093E23MCAA model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Goodman MSH093E23MCAA runs 360 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does Goodman MSH093E23MCAA cover?
Goodman MSH093E23MCAA covers 9,000-9,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Goodman MSH093E23MCAA handle extreme weather or cold snaps?
Goodman MSH093E23MCAA is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.
What refrigerant class and 2026 tax credit rules govern Goodman MSH093E23MCAA?
Goodman MSH093E23MCAA specifies R-410A compliance (PD ID 3999935); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in Goodman MSH093E23MCAA reach 25.0 SEER2?
Peak 25.0 SEER2 represents the top tested AHRI pairing for Goodman MSH093E23MCAA (PD ID 3999935); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Goodman MSH093E23MCAA?
Goodman MSH093E23MCAA requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include ApooDr ASG24-09H1B.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.