Skip to main content
Mini-Split Heat Pump · Franklin · 2 ENERGY STAR Combinations

Franklin MST183F32MHAA — Mini-Split Heat Pump Specifications

Franklin MST183F32MHAA (Mini-Split Heat Pump, PD ID 4573067) holds 2 ENERGY STAR certified SKUs rated at 27.0 SEER2 — #361 of 2,096 (Top 21.9%, 98 tied), +1.90 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). Franklin MST183F32MHAA — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 27.0 SEER2 and Heating Rating set at 11.0 HSPF2.

Max SEER2
27.0 SEER2
Heating Rating
11.0 HSPF2
Heating COP
2.1 COP
Cohort Rank
#361/2,096
Verified Combos
2 SKUs
Sample PD ID
4573067
Mini-Split Heat Pump Efficiency Spread across 2096 certified series (23.7 to 35.1 SEER2)
Franklin MST183F32MHAA Mini-Split Heat Pump Efficiency Spread Distribution Distribution of 2096 certified series from 23.7 to 35.1 SEER2. Franklin MST183F32MHAA sits at 27.0 SEER2; typical midpoint is 25.1 SEER2. 717 23.7 785 25.0 272 26.2 150 27.5 86 28.8 1 30.0 28 31.3 38 32.6 19 33.8 Median 25.1 SEER2 This model: 27.0 SEER2 (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
23.7 - 25.0 SEER2717Peer range
25.0 - 26.2 SEER2785Peer range
26.2 - 27.5 SEER2272This series
27.5 - 28.8 SEER2150Peer range
28.8 - 30.0 SEER286Peer range
30.0 - 31.3 SEER21Peer range
31.3 - 32.6 SEER228Peer range
32.6 - 33.8 SEER238Peer range
33.8 - 35.1 SEER219Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
Franklin MST183F32MHAA residential equipment inspection. ThermalSpec Editorial Photography

How does Franklin MST183F32MHAA rank across federal compliance and ENERGY STAR cohorts?

Franklin MST183F32MHAA ranks #361 of 2,096 (tied with 97 others at 27.0 SEER2, top 21.9%, more efficient than 78.1% of certified series) for Max SEER2 (+1.90 SEER2 vs 25.1 SEER2 category median) across 2 certified SKU combinations. Rated for cold-climate output (101.0% capacity retention at 5F) (1.6 nominal Tons at 19,000 BTU/h) charged with R-32. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.

Franklin MST183F32MHAA Cohort Metrics vs. Mini-Split Heat Pump Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max SEER2) #361 of 2,096 (Top 21.9%, 98 tied) +1.90 SEER2 vs 25.1 SEER2 category median
Heating HSPF2 vs Cohort 11.0 HSPF2 +0.50 HSPF2 vs 10.5 HSPF2 median
Peak 95F EER2 vs Cohort 16.0 EER2 +2.00 EER2 vs 14.0 EER2 median
5F Cold-Weather Capacity Retention 101.0% of 47F rating 5F COP 2.1
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Federal North & SE Heat Pump Minimum PASS Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 27.0 SEER2 / 11.0 HSPF2
Southwest Peak-Heat Criterion (AZ/CA/NM/NV) PASS Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 16.0 EER2
ENERGY STAR Cold Climate Spec CERTIFIED Cold Climate verified (1947/2096 series in category)
2026 Cleaner Refrigerant Rule R-454B / R-32 READY Listed refrigerant: R-32; newer R-454B/R-32 splits include indoor leak sensors

How much annual energy and operating cost does Franklin MST183F32MHAA require?

Modeled utility figures for Franklin MST183F32MHAA (Franklin) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max SEER2 ratings.

Cool_kWh = (19,000 BTU/h * 1,000 hrs / 27.0 SEER2) / 1,000 | Heat_kWh = 30,000 kBTU / 11.0 HSPF2

Assumes 1,000 cooling hrs + 30 MMBtu heating at US 51-state median 16.33 c/kWh (range 12.72 c NV to 47.18 c HI)

Operating BasisEstimated ValueSource Basis
Estimated Annual Cooling Energy704 kWh/yr$115/yr at US median
Estimated Annual Heating Energy (30 MMBtu)2,727 kWh/yr$445/yr at US median
Combined Annual Electricity Cost$560/yrState range: $436 (NV) to $1,619 (HI)
Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor1,898 kWh/yr$310/yr saved
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to Franklin MST183F32MHAA?

Showing 2 certified indoor-outdoor coil combinations from 2 total AHRI matched records filed for Franklin MST183F32MHAA (PD ID 4573067).

MST183F32MHAA Matched AHRI Coil 19,000 BTU/h 27.0 SEER2 / 11.0 HSPF2
MST183F32MHAA Matched AHRI Coil 19,000 BTU/h 24.5 SEER2 / 11.0 HSPF2

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Franklin MST183F32MHAA, review 3 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Franklin MST183F32MHAA: headline Max SEER2 reflects peak tested matches among 2 SKUs, not lower-rated sizes.
  • Catalog specs for Franklin MST183F32MHAA exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
  • Franklin MST183F32MHAA uses A2L R-32, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
Homeowner ScenarioRecommended Verification Path
Ideal Franklin MST183F32MHAA fitSingle-family replacement needing documented ENERGY STAR PD ID 4573067 with matching indoor air handler.
Skip Franklin MST183F32MHAA ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable mini-split heat pump models deliver similar efficiency?

Compare Franklin MST183F32MHAA against Goodman MST183G32MHAA and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.

Goodman MST183G32MHAA

27.0 SEER2 · 11.0 HSPF2 · 19,000 BTU/h

MDV M3OD31-18HFN8-M1XD

27.0 SEER2 · 11.0 HSPF2 · 19,000 BTU/h

Clima Smart CSU06HEI2NAM0T24

27.0 SEER2 · 10.0 HSPF2 · 20,000 BTU/h

Clima Smart MU-CSU18HEI2NAM0T24-3PO

27.0 SEER2 · 10.0 HSPF2 · 20,000 BTU/h

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Franklin MST183F32MHAA compare with peer Mini-Split Heat Pump units?

Franklin MST183F32MHAA holds #361 of 2,096 (Top 21.9%, 98 tied) out of 2,096 verified mini-split heat pump models (+1.90 SEER2 vs 25.1 SEER2 category median), spanning 2 certified SKUs up to 27.0 SEER2. Closest same-cohort alternatives include Goodman MST183G32MHAA.

DOE Regions

Where is Franklin MST183F32MHAA compliant for 2026 US installation?

Franklin MST183F32MHAA: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Franklin MST183F32MHAA model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Franklin MST183F32MHAA runs 704 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Franklin MST183F32MHAA cover?

Franklin MST183F32MHAA covers 19,000-19,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Franklin MST183F32MHAA handle extreme weather or cold snaps?

Yes, Franklin MST183F32MHAA carries ENERGY STAR Cold Climate certification (101.0% capacity retention at 5 F).

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Franklin MST183F32MHAA?

Franklin MST183F32MHAA specifies R-32 compliance (PD ID 4573067); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 2 certified SKUs in Franklin MST183F32MHAA reach 27.0 SEER2?

Peak 27.0 SEER2 represents the top tested AHRI pairing for Franklin MST183F32MHAA (PD ID 4573067); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Franklin MST183F32MHAA?

Franklin MST183F32MHAA requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Goodman MST183G32MHAA.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 8 pages.

Comparable HVAC Climate & Cost Metros