EMI MHSZ106DA — Mini-Split Heat Pump Specifications
EMI MHSZ106DA (Mini-Split Heat Pump, PD ID 3996687) holds 2 ENERGY STAR certified SKUs rated at 26.5 SEER2 — #467 of 2,096 (Top 25.9%, 76 tied), +1.40 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). EMI MHSZ106DA — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 26.5 SEER2 and Heating Rating set at 13.6 HSPF2.
- Max SEER2
- 26.5 SEER2
- Heating Rating
- 13.6 HSPF2
- Heating COP
- 2.1 COP
- Cohort Rank
- #467/2,096
- Verified Combos
- 2 SKUs
- Sample PD ID
- 3996687
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | Peer range |
| 25.0 - 26.2 SEER2 | 785 | Peer range |
| 26.2 - 27.5 SEER2 | 272 | This series |
| 27.5 - 28.8 SEER2 | 150 | Peer range |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |
How does EMI MHSZ106DA rank across federal compliance and ENERGY STAR cohorts?
EMI MHSZ106DA ranks #467 of 2,096 (tied with 75 others at 26.5 SEER2, top 25.9%, more efficient than 74.1% of certified series) for Max SEER2 (+1.40 SEER2 vs 25.1 SEER2 category median) across 2 certified SKU combinations. Rated for cold-climate output (107.1% capacity retention at 5F) (0.5 nominal Tons at 6,000 BTU/h) charged with R-410A. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #467 of 2,096 (Top 25.9%, 76 tied) | +1.40 SEER2 vs 25.1 SEER2 category median |
| Heating HSPF2 vs Cohort | 13.6 HSPF2 | +3.10 HSPF2 vs 10.5 HSPF2 median |
| Peak 95F EER2 vs Cohort | 15.8 EER2 | +1.80 EER2 vs 14.0 EER2 median |
| 5F Cold-Weather Capacity Retention | 107.1% of 47F rating | 5F COP 2.1 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 26.5 SEER2 / 13.6 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 15.8 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (1947/2096 series in category) |
| 2026 Cleaner Refrigerant Rule | OLDER R-410A | Listed refrigerant: R-410A; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does EMI MHSZ106DA require?
Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, EMI MHSZ106DA estimates reflect 2 certified SKU combinations tested under PD ID 3996687.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 226 kWh/yr | $37/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 2,206 kWh/yr | $360/yr at US median |
| Combined Annual Electricity Cost | $397/yr | State range: $309 (NV) to $1,147 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 1,988 kWh/yr | $325/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to EMI MHSZ106DA?
Showing 2 certified indoor-outdoor coil combinations from 2 total AHRI matched records filed for EMI MHSZ106DA (PD ID 3996687).
| MHSZ106DA | MHWAL06DA | 6,000 BTU/h | 26.5 SEER2 / 13.6 HSPF2 |
| MHSZ106DA | MHWAL06DA | 6,000 BTU/h | 26.5 SEER2 / 13.6 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on EMI MHSZ106DA, review 2 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across EMI MHSZ106DA: headline Max SEER2 reflects peak tested matches among 2 SKUs, not lower-rated sizes.
- Catalog specs for EMI MHSZ106DA exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal EMI MHSZ106DA fit | Single-family replacement needing documented ENERGY STAR PD ID 3996687 with matching indoor air handler. |
| Skip EMI MHSZ106DA if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable mini-split heat pump models deliver similar efficiency?
Compare EMI MHSZ106DA against 1HVAC ACIQ-06ZPL-HP230B and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does EMI MHSZ106DA compare with peer Mini-Split Heat Pump units?
EMI MHSZ106DA holds #467 of 2,096 (Top 25.9%, 76 tied) out of 2,096 verified mini-split heat pump models (+1.40 SEER2 vs 25.1 SEER2 category median), spanning 2 certified SKUs up to 26.5 SEER2. Closest same-cohort alternatives include 1HVAC ACIQ-06ZPL-HP230B.
Where is EMI MHSZ106DA compliant for 2026 US installation?
EMI MHSZ106DA: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does EMI MHSZ106DA model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, EMI MHSZ106DA runs 226 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does EMI MHSZ106DA cover?
EMI MHSZ106DA covers 6,000-6,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does EMI MHSZ106DA handle extreme weather or cold snaps?
Yes, EMI MHSZ106DA carries ENERGY STAR Cold Climate certification (107.1% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern EMI MHSZ106DA?
EMI MHSZ106DA specifies R-410A compliance (PD ID 3996687); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 2 certified SKUs in EMI MHSZ106DA reach 26.5 SEER2?
Peak 26.5 SEER2 represents the top tested AHRI pairing for EMI MHSZ106DA (PD ID 3996687); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to EMI MHSZ106DA?
EMI MHSZ106DA requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include 1HVAC ACIQ-06ZPL-HP230B.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.