Skip to main content
Mini-Split Heat Pump · ECO-AIR · 1 ENERGY STAR Combinations

ECO-AIR M3OJ-27HFN1-M — Mini-Split Heat Pump Specifications

ECO-AIR M3OJ-27HFN1-M (Mini-Split Heat Pump, PD ID 3891155) holds 1 ENERGY STAR certified SKU rated at 24.6 SEER2 — #1,391 of 2,096 (90 tied, beats 29.4% of peers), -0.50 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). ECO-AIR M3OJ-27HFN1-M — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 24.6 SEER2 and Heating Rating set at 9.5 HSPF2.

Max SEER2
24.6 SEER2
Heating Rating
9.5 HSPF2
Heating COP
2.0 COP
Cohort Rank
#1,391/2,096
Verified Combos
1 SKU
Sample PD ID
3891155
Mini-Split Heat Pump Efficiency Spread across 2096 certified series (23.7 to 35.1 SEER2)
ECO-AIR M3OJ-27HFN1-M Mini-Split Heat Pump Efficiency Spread Distribution Distribution of 2096 certified series from 23.7 to 35.1 SEER2. ECO-AIR M3OJ-27HFN1-M sits at 24.6 SEER2; typical midpoint is 25.1 SEER2. 717 23.7 785 25.0 272 26.2 150 27.5 86 28.8 1 30.0 28 31.3 38 32.6 19 33.8 Median 25.1 SEER2 This model: 24.6 SEER2 (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
23.7 - 25.0 SEER2717This series
25.0 - 26.2 SEER2785Peer range
26.2 - 27.5 SEER2272Peer range
27.5 - 28.8 SEER2150Peer range
28.8 - 30.0 SEER286Peer range
30.0 - 31.3 SEER21Peer range
31.3 - 32.6 SEER228Peer range
32.6 - 33.8 SEER238Peer range
33.8 - 35.1 SEER219Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
ECO-AIR M3OJ-27HFN1-M residential equipment inspection. ThermalSpec Editorial Photography

How does ECO-AIR M3OJ-27HFN1-M rank across federal compliance and ENERGY STAR cohorts?

ECO-AIR M3OJ-27HFN1-M ranks #1,391 of 2,096 (tied with 89 others at 24.6 SEER2, more efficient than 29.4% of certified series) for Max SEER2 (-0.50 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Built with Continuously variable modulation (2.3 nominal Tons at 28,000 BTU/h) charged with R-410A. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.

ECO-AIR M3OJ-27HFN1-M Cohort Metrics vs. Mini-Split Heat Pump Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max SEER2) #1,391 of 2,096 (90 tied, beats 29.4% of peers) -0.50 SEER2 vs 25.1 SEER2 category median
Heating HSPF2 vs Cohort 9.5 HSPF2 -1.00 HSPF2 vs 10.5 HSPF2 median
Peak 95F EER2 vs Cohort 12.7 EER2 -1.30 EER2 vs 14.0 EER2 median
5F Cold-Weather Capacity Retention 67.9% of 47F rating 5F COP 2.0
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Federal North & SE Heat Pump Minimum PASS Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 24.6 SEER2 / 9.5 HSPF2
Southwest Peak-Heat Criterion (AZ/CA/NM/NV) PASS Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 12.7 EER2
ENERGY STAR Cold Climate Spec STANDARD CLIMATE Designed for standard/mixed heating zones
2026 Cleaner Refrigerant Rule OLDER R-410A Listed refrigerant: R-410A; newer R-454B/R-32 splits include indoor leak sensors

How much annual energy and operating cost does ECO-AIR M3OJ-27HFN1-M require?

Annual cost outputs combine ECO-AIR M3OJ-27HFN1-M's 24.6 SEER2 rating and EIA national tariffs across single-family runtime hours.

Cool_kWh = (28,000 BTU/h * 1,000 hrs / 24.6 SEER2) / 1,000 | Heat_kWh = 30,000 kBTU / 9.5 HSPF2

Assumes 1,000 cooling hrs + 30 MMBtu heating at US 51-state median 16.33 c/kWh (range 12.72 c NV to 47.18 c HI)

Operating BasisEstimated ValueSource Basis
Estimated Annual Cooling Energy1,138 kWh/yr$186/yr at US median
Estimated Annual Heating Energy (30 MMBtu)3,158 kWh/yr$516/yr at US median
Combined Annual Electricity Cost$702/yrState range: $546 (NV) to $2,027 (HI)
Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor1,662 kWh/yr$271/yr saved
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to ECO-AIR M3OJ-27HFN1-M?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for ECO-AIR M3OJ-27HFN1-M (PD ID 3891155).

M3OJ-27HFN1-M Matched AHRI Coil 28,000 BTU/h 24.6 SEER2 / 9.5 HSPF2

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on ECO-AIR M3OJ-27HFN1-M, review 3 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across ECO-AIR M3OJ-27HFN1-M: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for ECO-AIR M3OJ-27HFN1-M exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
  • ECO-AIR M3OJ-27HFN1-M lacks ENERGY STAR Cold Climate 5F designation, so electric heat strips or dual-fuel backup matter in Zones 5-8.
Homeowner ScenarioRecommended Verification Path
Ideal ECO-AIR M3OJ-27HFN1-M fitSingle-family replacement needing documented ENERGY STAR PD ID 3891155 with matching indoor air handler.
Skip ECO-AIR M3OJ-27HFN1-M ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable mini-split heat pump models deliver similar efficiency?

Compare ECO-AIR M3OJ-27HFN1-M against 1HVAC ES-27Z-M3B and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.

1HVAC ES-27Z-M3B

24.6 SEER2 · 9.5 HSPF2 · 28,000 BTU/h

AC PRO A3OJ-27HFN1-M

24.6 SEER2 · 9.5 HSPF2 · 28,000 BTU/h

ACIQ ES-27Z-M3B

24.6 SEER2 · 9.5 HSPF2 · 28,000 BTU/h

AIREASE 4DHP2S30M-1P

24.6 SEER2 · 9.3 HSPF2 · 28,000 BTU/h

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does ECO-AIR M3OJ-27HFN1-M compare with peer Mini-Split Heat Pump units?

ECO-AIR M3OJ-27HFN1-M holds #1,391 of 2,096 (90 tied, beats 29.4% of peers) out of 2,096 verified mini-split heat pump models (-0.50 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 24.6 SEER2. Closest same-cohort alternatives include 1HVAC ES-27Z-M3B.

DOE Regions

Where is ECO-AIR M3OJ-27HFN1-M compliant for 2026 US installation?

ECO-AIR M3OJ-27HFN1-M: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does ECO-AIR M3OJ-27HFN1-M model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, ECO-AIR M3OJ-27HFN1-M runs 1,138 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does ECO-AIR M3OJ-27HFN1-M cover?

ECO-AIR M3OJ-27HFN1-M covers 28,000-28,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does ECO-AIR M3OJ-27HFN1-M handle extreme weather or cold snaps?

ECO-AIR M3OJ-27HFN1-M is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern ECO-AIR M3OJ-27HFN1-M?

ECO-AIR M3OJ-27HFN1-M specifies R-410A compliance (PD ID 3891155); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in ECO-AIR M3OJ-27HFN1-M reach 24.6 SEER2?

Peak 24.6 SEER2 represents the top tested AHRI pairing for ECO-AIR M3OJ-27HFN1-M (PD ID 3891155); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to ECO-AIR M3OJ-27HFN1-M?

ECO-AIR M3OJ-27HFN1-M requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include 1HVAC ES-27Z-M3B.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros