DIYCOOL ACIQ-09ZPL-HP230B — Mini-Split Heat Pump Specifications
DIYCOOL ACIQ-09ZPL-HP230B (Mini-Split Heat Pump, PD ID 2448411) holds 3 ENERGY STAR certified SKUs rated at 28.1 SEER2 — #196 of 2,096 (Top 11.9%, 54 tied), +3.00 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). DIYCOOL ACIQ-09ZPL-HP230B — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 28.1 SEER2 and Heating Rating set at 12.4 HSPF2.
- Max SEER2
- 28.1 SEER2
- Heating Rating
- 12.4 HSPF2
- Heating COP
- 2.0 COP
- Cohort Rank
- #196/2,096
- Verified Combos
- 3 SKUs
- Sample PD ID
- 2448411
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | Peer range |
| 25.0 - 26.2 SEER2 | 785 | Peer range |
| 26.2 - 27.5 SEER2 | 272 | Peer range |
| 27.5 - 28.8 SEER2 | 150 | This series |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |
How does DIYCOOL ACIQ-09ZPL-HP230B rank across federal compliance and ENERGY STAR cohorts?
DIYCOOL ACIQ-09ZPL-HP230B ranks #196 of 2,096 (tied with 53 others at 28.1 SEER2, top 11.9%, more efficient than 88.1% of certified series) for Max SEER2 (+3.00 SEER2 vs 25.1 SEER2 category median) across 3 certified SKU combinations. Rated for cold-climate output (96.3% capacity retention at 5F) (0.8 nominal Tons at 9,000 BTU/h) charged with R-410A. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #196 of 2,096 (Top 11.9%, 54 tied) | +3.00 SEER2 vs 25.1 SEER2 category median |
| Heating HSPF2 vs Cohort | 12.4 HSPF2 | +1.90 HSPF2 vs 10.5 HSPF2 median |
| Peak 95F EER2 vs Cohort | 16.2 EER2 | +2.20 EER2 vs 14.0 EER2 median |
| 5F Cold-Weather Capacity Retention | 96.3% of 47F rating | 5F COP 2.0 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 28.1 SEER2 / 12.4 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 16.2 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (1947/2096 series in category) |
| 2026 Cleaner Refrigerant Rule | OLDER R-410A | Listed refrigerant: R-410A; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does DIYCOOL ACIQ-09ZPL-HP230B require?
Annual cost outputs combine DIYCOOL ACIQ-09ZPL-HP230B's 28.1 SEER2 rating and EIA national tariffs across single-family runtime hours.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 320 kWh/yr | $52/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 2,419 kWh/yr | $395/yr at US median |
| Combined Annual Electricity Cost | $447/yr | State range: $348 (NV) to $1,292 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 1,890 kWh/yr | $309/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to DIYCOOL ACIQ-09ZPL-HP230B?
Showing 3 certified indoor-outdoor coil combinations from 3 total AHRI matched records filed for DIYCOOL ACIQ-09ZPL-HP230B (PD ID 2448411).
| ACIQ-09ZPL-HP230B | ACIQ-09W-HH-MC | 9,000 BTU/h | 28.1 SEER2 / 11.5 HSPF2 |
| ACIQ-09ZPL-HP230B | ACIQ-09W-HH-MB | 9,000 BTU/h | 28.1 SEER2 / 11.5 HSPF2 |
| ACIQ-09ZPL-HP230B | SCC-0609-HH-M | 9,000 BTU/h | 24.0 SEER2 / 12.4 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on DIYCOOL ACIQ-09ZPL-HP230B, review 2 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across DIYCOOL ACIQ-09ZPL-HP230B: headline Max SEER2 reflects peak tested matches among 3 SKUs, not lower-rated sizes.
- Catalog specs for DIYCOOL ACIQ-09ZPL-HP230B exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal DIYCOOL ACIQ-09ZPL-HP230B fit | Single-family replacement needing documented ENERGY STAR PD ID 2448411 with matching indoor air handler. |
| Skip DIYCOOL ACIQ-09ZPL-HP230B if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable mini-split heat pump models deliver similar efficiency?
Compare DIYCOOL ACIQ-09ZPL-HP230B against 1HVAC ACIQ-09ZPL-HP230B and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does DIYCOOL ACIQ-09ZPL-HP230B compare with peer Mini-Split Heat Pump units?
DIYCOOL ACIQ-09ZPL-HP230B holds #196 of 2,096 (Top 11.9%, 54 tied) out of 2,096 verified mini-split heat pump models (+3.00 SEER2 vs 25.1 SEER2 category median), spanning 3 certified SKUs up to 28.1 SEER2. Closest same-cohort alternatives include 1HVAC ACIQ-09ZPL-HP230B.
Where is DIYCOOL ACIQ-09ZPL-HP230B compliant for 2026 US installation?
DIYCOOL ACIQ-09ZPL-HP230B: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does DIYCOOL ACIQ-09ZPL-HP230B model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, DIYCOOL ACIQ-09ZPL-HP230B runs 320 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does DIYCOOL ACIQ-09ZPL-HP230B cover?
DIYCOOL ACIQ-09ZPL-HP230B covers 9,000-9,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does DIYCOOL ACIQ-09ZPL-HP230B handle extreme weather or cold snaps?
Yes, DIYCOOL ACIQ-09ZPL-HP230B carries ENERGY STAR Cold Climate certification (96.3% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern DIYCOOL ACIQ-09ZPL-HP230B?
DIYCOOL ACIQ-09ZPL-HP230B specifies R-410A compliance (PD ID 2448411); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 3 certified SKUs in DIYCOOL ACIQ-09ZPL-HP230B reach 28.1 SEER2?
Peak 28.1 SEER2 represents the top tested AHRI pairing for DIYCOOL ACIQ-09ZPL-HP230B (PD ID 2448411); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to DIYCOOL ACIQ-09ZPL-HP230B?
DIYCOOL ACIQ-09ZPL-HP230B requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include 1HVAC ACIQ-09ZPL-HP230B.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages