Clima Smart MU-CSU36HEI2NAM0T24-5PO — Mini-Split Heat Pump Specifications
Clima Smart MU-CSU36HEI2NAM0T24-5PO (Mini-Split Heat Pump, PD ID 4520652) holds 1 ENERGY STAR certified SKU rated at 25.0 SEER2 — #1,069 of 2,096 (311 tied, beats 34.2% of peers), -0.10 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). Clima Smart MU-CSU36HEI2NAM0T24-5PO — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 25.0 SEER2 and Heating Rating set at 10.0 HSPF2.
- Max SEER2
- 25.0 SEER2
- Heating Rating
- 10.0 HSPF2
- Heating COP
- 2.0 COP
- Cohort Rank
- #1,069/2,096
- Verified Combos
- 1 SKU
- Sample PD ID
- 4520652
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | Peer range |
| 25.0 - 26.2 SEER2 | 785 | This series |
| 26.2 - 27.5 SEER2 | 272 | Peer range |
| 27.5 - 28.8 SEER2 | 150 | Peer range |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |
How does Clima Smart MU-CSU36HEI2NAM0T24-5PO rank across federal compliance and ENERGY STAR cohorts?
Clima Smart MU-CSU36HEI2NAM0T24-5PO ranks #1,069 of 2,096 (tied with 310 others at 25.0 SEER2, more efficient than 34.2% of certified series) for Max SEER2 (-0.10 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (83.3% capacity retention at 5F) (3.0 nominal Tons at 36,000 BTU/h) charged with R-454B. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #1,069 of 2,096 (311 tied, beats 34.2% of peers) | -0.10 SEER2 vs 25.1 SEER2 category median |
| Heating HSPF2 vs Cohort | 10.0 HSPF2 | -0.50 HSPF2 vs 10.5 HSPF2 median |
| Peak 95F EER2 vs Cohort | 13.6 EER2 | -0.40 EER2 vs 14.0 EER2 median |
| 5F Cold-Weather Capacity Retention | 83.3% of 47F rating | 5F COP 2.0 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 25.0 SEER2 / 10.0 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 13.6 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (1947/2096 series in category) |
| 2026 Cleaner Refrigerant Rule | R-454B / R-32 READY | Listed refrigerant: R-454B; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does Clima Smart MU-CSU36HEI2NAM0T24-5PO require?
Modeled utility figures for Clima Smart MU-CSU36HEI2NAM0T24-5PO (Clima Smart) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max SEER2 ratings.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 1,440 kWh/yr | $235/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 3,000 kWh/yr | $490/yr at US median |
| Combined Annual Electricity Cost | $725/yr | State range: $565 (NV) to $2,095 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 2,077 kWh/yr | $339/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to Clima Smart MU-CSU36HEI2NAM0T24-5PO?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Clima Smart MU-CSU36HEI2NAM0T24-5PO (PD ID 4520652).
| MU-CSU36HEI2NAM0T24-5PO | Matched AHRI Coil | 36,000 BTU/h | 25.0 SEER2 / 10.0 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Clima Smart MU-CSU36HEI2NAM0T24-5PO, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Clima Smart MU-CSU36HEI2NAM0T24-5PO: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Clima Smart MU-CSU36HEI2NAM0T24-5PO exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- Clima Smart MU-CSU36HEI2NAM0T24-5PO uses A2L R-454B, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Clima Smart MU-CSU36HEI2NAM0T24-5PO fit | Single-family replacement needing documented ENERGY STAR PD ID 4520652 with matching indoor air handler. |
| Skip Clima Smart MU-CSU36HEI2NAM0T24-5PO if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable mini-split heat pump models deliver similar efficiency?
Compare Clima Smart MU-CSU36HEI2NAM0T24-5PO against DELLA 048-TPH-MODU-1D5 and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Clima Smart MU-CSU36HEI2NAM0T24-5PO compare with peer Mini-Split Heat Pump units?
Clima Smart MU-CSU36HEI2NAM0T24-5PO holds #1,069 of 2,096 (311 tied, beats 34.2% of peers) out of 2,096 verified mini-split heat pump models (-0.10 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 25.0 SEER2. Closest same-cohort alternatives include DELLA 048-TPH-MODU-1D5.
Where is Clima Smart MU-CSU36HEI2NAM0T24-5PO compliant for 2026 US installation?
Clima Smart MU-CSU36HEI2NAM0T24-5PO: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Clima Smart MU-CSU36HEI2NAM0T24-5PO model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Clima Smart MU-CSU36HEI2NAM0T24-5PO runs 1,440 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does Clima Smart MU-CSU36HEI2NAM0T24-5PO cover?
Clima Smart MU-CSU36HEI2NAM0T24-5PO covers 36,000-36,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Clima Smart MU-CSU36HEI2NAM0T24-5PO handle extreme weather or cold snaps?
Yes, Clima Smart MU-CSU36HEI2NAM0T24-5PO carries ENERGY STAR Cold Climate certification (83.3% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern Clima Smart MU-CSU36HEI2NAM0T24-5PO?
Clima Smart MU-CSU36HEI2NAM0T24-5PO specifies R-454B compliance (PD ID 4520652); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in Clima Smart MU-CSU36HEI2NAM0T24-5PO reach 25.0 SEER2?
Peak 25.0 SEER2 represents the top tested AHRI pairing for Clima Smart MU-CSU36HEI2NAM0T24-5PO (PD ID 4520652); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Clima Smart MU-CSU36HEI2NAM0T24-5PO?
Clima Smart MU-CSU36HEI2NAM0T24-5PO requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include DELLA 048-TPH-MODU-1D5.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.