Mini-Split Heat Pump · Cadet · 1 ENERGY STAR Combinations

Cadet 500006880 — Mini-Split Heat Pump Specifications

Cadet 500006880 (Mini-Split Heat Pump, PD ID 4623957) holds 1 ENERGY STAR certified SKU rated at 26.0 SEER2 — #595 of 2,096 (Top 33.4%, 106 tied), +0.90 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). Cadet 500006880 — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 26.0 SEER2 and Heating Rating set at 12.5 HSPF2.

Max SEER2
26.0 SEER2
Heating Rating
12.5 HSPF2
Heating COP
1.8 COP
Cohort Rank
#595/2,096
Verified Combos
1 SKU
Sample PD ID
4623957
Mini-Split Heat Pump Efficiency Spread across 2096 certified series (23.7 to 35.1 SEER2)
Cadet 500006880 Mini-Split Heat Pump Efficiency Spread Distribution Distribution of 2096 certified series from 23.7 to 35.1 SEER2. Cadet 500006880 sits at 26.0 SEER2; typical midpoint is 25.1 SEER2. 717 23.7 785 25.0 272 26.2 150 27.5 86 28.8 1 30.0 28 31.3 38 32.6 19 33.8 Median 25.1 SEER2 This model: 26.0 SEER2 (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
23.7 - 25.0 SEER2717Peer range
25.0 - 26.2 SEER2785This series
26.2 - 27.5 SEER2272Peer range
27.5 - 28.8 SEER2150Peer range
28.8 - 30.0 SEER286Peer range
30.0 - 31.3 SEER21Peer range
31.3 - 32.6 SEER228Peer range
32.6 - 33.8 SEER238Peer range
33.8 - 35.1 SEER219Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
Cadet 500006880 residential equipment inspection. ThermalSpec Editorial Photography

How does Cadet 500006880 rank across federal compliance and ENERGY STAR cohorts?

Cadet 500006880 ranks #595 of 2,096 (tied with 105 others at 26.0 SEER2, top 33.4%, more efficient than 66.6% of certified series) for Max SEER2 (+0.90 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (95.8% capacity retention at 5F) (0.8 nominal Tons at 9,000 BTU/h) charged with R-454B. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.

Cadet 500006880 Cohort Metrics vs. Mini-Split Heat Pump Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max SEER2) #595 of 2,096 (Top 33.4%, 106 tied) +0.90 SEER2 vs 25.1 SEER2 category median
Heating HSPF2 vs Cohort 12.5 HSPF2 +2.00 HSPF2 vs 10.5 HSPF2 median
Peak 95F EER2 vs Cohort 15.0 EER2 +1.00 EER2 vs 14.0 EER2 median
5F Cold-Weather Capacity Retention 95.8% of 47F rating 5F COP 1.8
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Federal North & SE Heat Pump Minimum PASS Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 26.0 SEER2 / 12.5 HSPF2
Southwest Peak-Heat Criterion (AZ/CA/NM/NV) PASS Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 15.0 EER2
ENERGY STAR Cold Climate Spec CERTIFIED Cold Climate verified (1947/2096 series in category)
2026 Cleaner Refrigerant Rule R-454B / R-32 READY Listed refrigerant: R-454B; newer R-454B/R-32 splits include indoor leak sensors

How much annual energy and operating cost does Cadet 500006880 require?

Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, Cadet 500006880 estimates reflect 1 certified SKU combination tested under PD ID 4623957.

Cool_kWh = (9,000 BTU/h * 1,000 hrs / 26.0 SEER2) / 1,000 | Heat_kWh = 30,000 kBTU / 12.5 HSPF2

Assumes 1,000 cooling hrs + 30 MMBtu heating at US 51-state median 16.33 c/kWh (range 12.72 c NV to 47.18 c HI)

Operating BasisEstimated ValueSource Basis
Estimated Annual Cooling Energy346 kWh/yr$57/yr at US median
Estimated Annual Heating Energy (30 MMBtu)2,400 kWh/yr$392/yr at US median
Combined Annual Electricity Cost$448/yrState range: $349 (NV) to $1,296 (HI)
Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor1,883 kWh/yr$307/yr saved
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to Cadet 500006880?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Cadet 500006880 (PD ID 4623957).

500006880 500006872 9,000 BTU/h 26.0 SEER2 / 12.5 HSPF2

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Cadet 500006880, review 3 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Cadet 500006880: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for Cadet 500006880 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
  • Cadet 500006880 uses A2L R-454B, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
Homeowner ScenarioRecommended Verification Path
Ideal Cadet 500006880 fitSingle-family replacement needing documented ENERGY STAR PD ID 4623957 with matching indoor air handler.
Skip Cadet 500006880 ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable mini-split heat pump models deliver similar efficiency?

Compare Cadet 500006880 against AC PRO MHPC-H-009BSB and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.

AC PRO MHPC-H-009BSB

26.0 SEER2 · 13.9 HSPF2 · 9,000 BTU/h

ACIQ-09ZS-HP230C

26.0 SEER2 · 13.9 HSPF2 · 9,000 BTU/h

AI AIR CONDITIONING AO24-09N2-M1

26.0 SEER2 · 13.9 HSPF2 · 9,000 BTU/h

Airquest D5CSRAH09AAK

26.0 SEER2 · 13.9 HSPF2 · 9,000 BTU/h

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Cadet 500006880 compare with peer Mini-Split Heat Pump units?

Cadet 500006880 holds #595 of 2,096 (Top 33.4%, 106 tied) out of 2,096 verified mini-split heat pump models (+0.90 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 26.0 SEER2. Closest same-cohort alternatives include AC PRO MHPC-H-009BSB.

DOE Regions

Where is Cadet 500006880 compliant for 2026 US installation?

Cadet 500006880: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Cadet 500006880 model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Cadet 500006880 runs 346 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Cadet 500006880 cover?

Cadet 500006880 covers 9,000-9,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Cadet 500006880 handle extreme weather or cold snaps?

Yes, Cadet 500006880 carries ENERGY STAR Cold Climate certification (95.8% capacity retention at 5 F).

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Cadet 500006880?

Cadet 500006880 specifies R-454B compliance (PD ID 4623957); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in Cadet 500006880 reach 26.0 SEER2?

Peak 26.0 SEER2 represents the top tested AHRI pairing for Cadet 500006880 (PD ID 4623957); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Cadet 500006880?

Cadet 500006880 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include AC PRO MHPC-H-009BSB.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)