Breeze33 HSZ12H424ZMO — Mini-Split Heat Pump Specifications
Breeze33 HSZ12H424ZMO (Mini-Split Heat Pump, PD ID 2470171) holds 1 ENERGY STAR certified SKU rated at 24.2 SEER2 — #1,591 of 2,096 (8 tied, beats 23.8% of peers), -0.90 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). Breeze33 HSZ12H424ZMO — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 24.2 SEER2 and Heating Rating set at 10.7 HSPF2.
- Max SEER2
- 24.2 SEER2
- Heating Rating
- 10.7 HSPF2
- Heating COP
- 1.99 COP
- Cohort Rank
- #1,591/2,096
- Verified Combos
- 1 SKU
- Sample PD ID
- 2470171
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | This series |
| 25.0 - 26.2 SEER2 | 785 | Peer range |
| 26.2 - 27.5 SEER2 | 272 | Peer range |
| 27.5 - 28.8 SEER2 | 150 | Peer range |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |
How does Breeze33 HSZ12H424ZMO rank across federal compliance and ENERGY STAR cohorts?
Breeze33 HSZ12H424ZMO ranks #1,591 of 2,096 (tied with 7 others at 24.2 SEER2, more efficient than 23.8% of certified series) for Max SEER2 (-0.90 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (99.2% capacity retention at 5F) (1.0 nominal Tons at 12,000 BTU/h) charged with R-410A. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #1,591 of 2,096 (8 tied, beats 23.8% of peers) | -0.90 SEER2 vs 25.1 SEER2 category median |
| Heating HSPF2 vs Cohort | 10.7 HSPF2 | +0.20 HSPF2 vs 10.5 HSPF2 median |
| Peak 95F EER2 vs Cohort | 13.3 EER2 | -0.70 EER2 vs 14.0 EER2 median |
| 5F Cold-Weather Capacity Retention | 99.2% of 47F rating | 5F COP 1.99 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 24.2 SEER2 / 10.7 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 13.3 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (1947/2096 series in category) |
| 2026 Cleaner Refrigerant Rule | OLDER R-410A | Listed refrigerant: R-410A; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does Breeze33 HSZ12H424ZMO require?
Modeled utility figures for Breeze33 HSZ12H424ZMO (Breeze33) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max SEER2 ratings.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 496 kWh/yr | $81/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 2,804 kWh/yr | $458/yr at US median |
| Combined Annual Electricity Cost | $539/yr | State range: $420 (NV) to $1,557 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 1,539 kWh/yr | $251/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to Breeze33 HSZ12H424ZMO?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Breeze33 HSZ12H424ZMO (PD ID 2470171).
| HSZ12H424ZMO | C12H424ZMI | 12,000 BTU/h | 24.2 SEER2 / 10.7 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Breeze33 HSZ12H424ZMO, review 2 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Breeze33 HSZ12H424ZMO: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Breeze33 HSZ12H424ZMO exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Breeze33 HSZ12H424ZMO fit | Single-family replacement needing documented ENERGY STAR PD ID 2470171 with matching indoor air handler. |
| Skip Breeze33 HSZ12H424ZMO if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable mini-split heat pump models deliver similar efficiency?
Compare Breeze33 HSZ12H424ZMO against DuraSTAR DRA1H12S1A and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Breeze33 HSZ12H424ZMO compare with peer Mini-Split Heat Pump units?
Breeze33 HSZ12H424ZMO holds #1,591 of 2,096 (8 tied, beats 23.8% of peers) out of 2,096 verified mini-split heat pump models (-0.90 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 24.2 SEER2. Closest same-cohort alternatives include DuraSTAR DRA1H12S1A.
Where is Breeze33 HSZ12H424ZMO compliant for 2026 US installation?
Breeze33 HSZ12H424ZMO: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Breeze33 HSZ12H424ZMO model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Breeze33 HSZ12H424ZMO runs 496 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does Breeze33 HSZ12H424ZMO cover?
Breeze33 HSZ12H424ZMO covers 12,000-12,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Breeze33 HSZ12H424ZMO handle extreme weather or cold snaps?
Yes, Breeze33 HSZ12H424ZMO carries ENERGY STAR Cold Climate certification (99.2% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern Breeze33 HSZ12H424ZMO?
Breeze33 HSZ12H424ZMO specifies R-410A compliance (PD ID 2470171); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in Breeze33 HSZ12H424ZMO reach 24.2 SEER2?
Peak 24.2 SEER2 represents the top tested AHRI pairing for Breeze33 HSZ12H424ZMO (PD ID 2470171); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Breeze33 HSZ12H424ZMO?
Breeze33 HSZ12H424ZMO requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include DuraSTAR DRA1H12S1A.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 7 pages.