BLUERIDGE BXS4Z12UCV — Mini-Split Heat Pump Specifications

BLUERIDGE BXS4Z12UCV (Mini-Split Heat Pump, PD ID 4428984) holds 1 ENERGY STAR certified SKU rated at 24.5 SEER2 — #1,481 of 2,096 (108 tied, beats 24.2% of peers), -0.60 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). BLUERIDGE BXS4Z12UCV — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 24.5 SEER2 and Heating Rating set at 9.5 HSPF2.

Max SEER2
24.5 SEER2
Heating Rating
9.5 HSPF2
Heating COP
1.95 COP
Cohort Rank
#1,481/2,096
Verified Combos
1 SKU
Sample PD ID
4428984
Mini-Split Heat Pump Efficiency Spread across 2096 certified series (23.7 to 35.1 SEER2)
BLUERIDGE BXS4Z12UCV Mini-Split Heat Pump Efficiency Spread Distribution Distribution of 2096 certified series from 23.7 to 35.1 SEER2. BLUERIDGE BXS4Z12UCV sits at 24.5 SEER2; typical midpoint is 25.1 SEER2. 717 23.7 785 25.0 272 26.2 150 27.5 86 28.8 1 30.0 28 31.3 38 32.6 19 33.8 Median 25.1 SEER2 This model: 24.5 SEER2 (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
23.7 - 25.0 SEER2717This series
25.0 - 26.2 SEER2785Peer range
26.2 - 27.5 SEER2272Peer range
27.5 - 28.8 SEER2150Peer range
28.8 - 30.0 SEER286Peer range
30.0 - 31.3 SEER21Peer range
31.3 - 32.6 SEER228Peer range
32.6 - 33.8 SEER238Peer range
33.8 - 35.1 SEER219Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
BLUERIDGE BXS4Z12UCV residential equipment inspection. ThermalSpec Editorial Photography

How does BLUERIDGE BXS4Z12UCV rank across federal compliance and ENERGY STAR cohorts?

BLUERIDGE BXS4Z12UCV ranks #1,481 of 2,096 (tied with 107 others at 24.5 SEER2, more efficient than 24.2% of certified series) for Max SEER2 (-0.60 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (79.2% capacity retention at 5F) (1.0 nominal Tons at 12,000 BTU/h) charged with R-32. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.

BLUERIDGE BXS4Z12UCV Cohort Metrics vs. Mini-Split Heat Pump Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max SEER2) #1,481 of 2,096 (108 tied, beats 24.2% of peers) -0.60 SEER2 vs 25.1 SEER2 category median
Heating HSPF2 vs Cohort 9.5 HSPF2 -1.00 HSPF2 vs 10.5 HSPF2 median
Peak 95F EER2 vs Cohort 13.0 EER2 -1.00 EER2 vs 14.0 EER2 median
5F Cold-Weather Capacity Retention 79.2% of 47F rating 5F COP 1.95
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Federal North & SE Heat Pump Minimum PASS Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 24.5 SEER2 / 9.5 HSPF2
Southwest Peak-Heat Criterion (AZ/CA/NM/NV) PASS Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 13.0 EER2
ENERGY STAR Cold Climate Spec CERTIFIED Cold Climate verified (1947/2096 series in category)
2026 Cleaner Refrigerant Rule R-454B / R-32 READY Listed refrigerant: R-32; newer R-454B/R-32 splits include indoor leak sensors

How much annual energy and operating cost does BLUERIDGE BXS4Z12UCV require?

Annual cost outputs combine BLUERIDGE BXS4Z12UCV's 24.5 SEER2 rating and EIA national tariffs across single-family runtime hours.

Cool_kWh = (12,000 BTU/h * 1,000 hrs / 24.5 SEER2) / 1,000 | Heat_kWh = 30,000 kBTU / 9.5 HSPF2

Assumes 1,000 cooling hrs + 30 MMBtu heating at US 51-state median 16.33 c/kWh (range 12.72 c NV to 47.18 c HI)

Operating BasisEstimated ValueSource Basis
Estimated Annual Cooling Energy490 kWh/yr$80/yr at US median
Estimated Annual Heating Energy (30 MMBtu)3,158 kWh/yr$516/yr at US median
Combined Annual Electricity Cost$596/yrState range: $464 (NV) to $1,721 (HI)
Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor1,191 kWh/yr$194/yr saved
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to BLUERIDGE BXS4Z12UCV?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for BLUERIDGE BXS4Z12UCV (PD ID 4428984).

BXS4Z12UCV BXS4Z12WMV 12,000 BTU/h 24.5 SEER2 / 9.5 HSPF2

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on BLUERIDGE BXS4Z12UCV, review 3 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across BLUERIDGE BXS4Z12UCV: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for BLUERIDGE BXS4Z12UCV exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
  • BLUERIDGE BXS4Z12UCV uses A2L R-32, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
Homeowner ScenarioRecommended Verification Path
Ideal BLUERIDGE BXS4Z12UCV fitSingle-family replacement needing documented ENERGY STAR PD ID 4428984 with matching indoor air handler.
Skip BLUERIDGE BXS4Z12UCV ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable mini-split heat pump models deliver similar efficiency?

Compare BLUERIDGE BXS4Z12UCV against AireForce DXH12PSK3IH and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.

AireForce DXH12PSK3IH

24.5 SEER2 · 9.5 HSPF2 · 12,000 BTU/h

Airtemp DXH12PSK3IH

24.5 SEER2 · 9.5 HSPF2 · 12,000 BTU/h

BOREAL KUL12HPJ132OA

24.5 SEER2 · 9.5 HSPF2 · 12,000 BTU/h

BOREAL KUL12HPL132OA

24.5 SEER2 · 9.5 HSPF2 · 12,000 BTU/h

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does BLUERIDGE BXS4Z12UCV compare with peer Mini-Split Heat Pump units?

BLUERIDGE BXS4Z12UCV holds #1,481 of 2,096 (108 tied, beats 24.2% of peers) out of 2,096 verified mini-split heat pump models (-0.60 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 24.5 SEER2. Closest same-cohort alternatives include AireForce DXH12PSK3IH.

DOE Regions

Where is BLUERIDGE BXS4Z12UCV compliant for 2026 US installation?

BLUERIDGE BXS4Z12UCV: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does BLUERIDGE BXS4Z12UCV model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, BLUERIDGE BXS4Z12UCV runs 490 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does BLUERIDGE BXS4Z12UCV cover?

BLUERIDGE BXS4Z12UCV covers 12,000-12,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does BLUERIDGE BXS4Z12UCV handle extreme weather or cold snaps?

Yes, BLUERIDGE BXS4Z12UCV carries ENERGY STAR Cold Climate certification (79.2% capacity retention at 5 F).

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern BLUERIDGE BXS4Z12UCV?

BLUERIDGE BXS4Z12UCV specifies R-32 compliance (PD ID 4428984); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in BLUERIDGE BXS4Z12UCV reach 24.5 SEER2?

Peak 24.5 SEER2 represents the top tested AHRI pairing for BLUERIDGE BXS4Z12UCV (PD ID 4428984); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to BLUERIDGE BXS4Z12UCV?

BLUERIDGE BXS4Z12UCV requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include AireForce DXH12PSK3IH.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)