BLUERIDGE BXS4Z09UCV — Mini-Split Heat Pump Specifications
BLUERIDGE BXS4Z09UCV (Mini-Split Heat Pump, PD ID 4428981) holds 1 ENERGY STAR certified SKU rated at 27.0 SEER2 — #361 of 2,096 (Top 21.9%, 98 tied), +1.90 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). BLUERIDGE BXS4Z09UCV — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 27.0 SEER2 and Heating Rating set at 10.5 HSPF2.
- Max SEER2
- 27.0 SEER2
- Heating Rating
- 10.5 HSPF2
- Heating COP
- 1.83 COP
- Cohort Rank
- #361/2,096
- Verified Combos
- 1 SKU
- Sample PD ID
- 4428981
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | Peer range |
| 25.0 - 26.2 SEER2 | 785 | Peer range |
| 26.2 - 27.5 SEER2 | 272 | This series |
| 27.5 - 28.8 SEER2 | 150 | Peer range |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |
How does BLUERIDGE BXS4Z09UCV rank across federal compliance and ENERGY STAR cohorts?
BLUERIDGE BXS4Z09UCV ranks #361 of 2,096 (tied with 97 others at 27.0 SEER2, top 21.9%, more efficient than 78.1% of certified series) for Max SEER2 (+1.90 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (95.0% capacity retention at 5F) (0.8 nominal Tons at 9,100 BTU/h) charged with R-32. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #361 of 2,096 (Top 21.9%, 98 tied) | +1.90 SEER2 vs 25.1 SEER2 category median |
| Heating HSPF2 vs Cohort | 10.5 HSPF2 | Equal to 10.5 HSPF2 median |
| Peak 95F EER2 vs Cohort | 15.0 EER2 | +1.00 EER2 vs 14.0 EER2 median |
| 5F Cold-Weather Capacity Retention | 95.0% of 47F rating | 5F COP 1.83 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 27.0 SEER2 / 10.5 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 15.0 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (1947/2096 series in category) |
| 2026 Cleaner Refrigerant Rule | R-454B / R-32 READY | Listed refrigerant: R-32; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does BLUERIDGE BXS4Z09UCV require?
Annual cost outputs combine BLUERIDGE BXS4Z09UCV's 27.0 SEER2 rating and EIA national tariffs across single-family runtime hours.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 337 kWh/yr | $55/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 2,857 kWh/yr | $467/yr at US median |
| Combined Annual Electricity Cost | $522/yr | State range: $406 (NV) to $1,507 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 1,442 kWh/yr | $235/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to BLUERIDGE BXS4Z09UCV?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for BLUERIDGE BXS4Z09UCV (PD ID 4428981).
| BXS4Z09UCV | BXS4Z09WMV | 9,100 BTU/h | 27.0 SEER2 / 10.5 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on BLUERIDGE BXS4Z09UCV, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across BLUERIDGE BXS4Z09UCV: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for BLUERIDGE BXS4Z09UCV exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- BLUERIDGE BXS4Z09UCV uses A2L R-32, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal BLUERIDGE BXS4Z09UCV fit | Single-family replacement needing documented ENERGY STAR PD ID 4428981 with matching indoor air handler. |
| Skip BLUERIDGE BXS4Z09UCV if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable mini-split heat pump models deliver similar efficiency?
Compare BLUERIDGE BXS4Z09UCV against BOREAL KUL09HPL132OA and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does BLUERIDGE BXS4Z09UCV compare with peer Mini-Split Heat Pump units?
BLUERIDGE BXS4Z09UCV holds #361 of 2,096 (Top 21.9%, 98 tied) out of 2,096 verified mini-split heat pump models (+1.90 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 27.0 SEER2. Closest same-cohort alternatives include BOREAL KUL09HPL132OA.
Where is BLUERIDGE BXS4Z09UCV compliant for 2026 US installation?
BLUERIDGE BXS4Z09UCV: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does BLUERIDGE BXS4Z09UCV model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, BLUERIDGE BXS4Z09UCV runs 337 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does BLUERIDGE BXS4Z09UCV cover?
BLUERIDGE BXS4Z09UCV covers 9,100-9,100 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does BLUERIDGE BXS4Z09UCV handle extreme weather or cold snaps?
Yes, BLUERIDGE BXS4Z09UCV carries ENERGY STAR Cold Climate certification (95.0% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern BLUERIDGE BXS4Z09UCV?
BLUERIDGE BXS4Z09UCV specifies R-32 compliance (PD ID 4428981); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in BLUERIDGE BXS4Z09UCV reach 27.0 SEER2?
Peak 27.0 SEER2 represents the top tested AHRI pairing for BLUERIDGE BXS4Z09UCV (PD ID 4428981); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to BLUERIDGE BXS4Z09UCV?
BLUERIDGE BXS4Z09UCV requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include BOREAL KUL09HPL132OA.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 7 pages.