BLUERIDGE BMS925XC — Mini-Split Heat Pump Specifications
BLUERIDGE BMS925XC (Mini-Split Heat Pump, PD ID 3712109) holds 1 ENERGY STAR certified SKU rated at 25.4 SEER2 — #957 of 2,096 (Top 47.6%, 42 tied), +0.30 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). BLUERIDGE BMS925XC — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 25.4 SEER2 and Heating Rating set at 10.0 HSPF2.
- Max SEER2
- 25.4 SEER2
- Heating Rating
- 10.0 HSPF2
- Heating COP
- 2.23 COP
- Cohort Rank
- #957/2,096
- Verified Combos
- 1 SKU
- Sample PD ID
- 3712109
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | Peer range |
| 25.0 - 26.2 SEER2 | 785 | This series |
| 26.2 - 27.5 SEER2 | 272 | Peer range |
| 27.5 - 28.8 SEER2 | 150 | Peer range |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |
How does BLUERIDGE BMS925XC rank across federal compliance and ENERGY STAR cohorts?
BLUERIDGE BMS925XC ranks #957 of 2,096 (tied with 41 others at 25.4 SEER2, top 47.6%, more efficient than 52.4% of certified series) for Max SEER2 (+0.30 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (72.0% capacity retention at 5F) (0.8 nominal Tons at 9,000 BTU/h) charged with R-454B. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #957 of 2,096 (Top 47.6%, 42 tied) | +0.30 SEER2 vs 25.1 SEER2 category median |
| Heating HSPF2 vs Cohort | 10.0 HSPF2 | -0.50 HSPF2 vs 10.5 HSPF2 median |
| Peak 95F EER2 vs Cohort | 14.5 EER2 | +0.50 EER2 vs 14.0 EER2 median |
| 5F Cold-Weather Capacity Retention | 72.0% of 47F rating | 5F COP 2.23 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 25.4 SEER2 / 10.0 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 14.5 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (1947/2096 series in category) |
| 2026 Cleaner Refrigerant Rule | R-454B / R-32 READY | Listed refrigerant: R-454B; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does BLUERIDGE BMS925XC require?
Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, BLUERIDGE BMS925XC estimates reflect 1 certified SKU combination tested under PD ID 3712109.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 354 kWh/yr | $58/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 3,000 kWh/yr | $490/yr at US median |
| Combined Annual Electricity Cost | $548/yr | State range: $427 (NV) to $1,582 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 1,275 kWh/yr | $208/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to BLUERIDGE BMS925XC?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for BLUERIDGE BMS925XC (PD ID 3712109).
| BMS925XC | BMS925XW | 9,000 BTU/h | 25.4 SEER2 / 10.0 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on BLUERIDGE BMS925XC, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across BLUERIDGE BMS925XC: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for BLUERIDGE BMS925XC exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- BLUERIDGE BMS925XC uses A2L R-454B, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal BLUERIDGE BMS925XC fit | Single-family replacement needing documented ENERGY STAR PD ID 3712109 with matching indoor air handler. |
| Skip BLUERIDGE BMS925XC if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable mini-split heat pump models deliver similar efficiency?
Compare BLUERIDGE BMS925XC against CanAir 4C25SCH09H11 and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does BLUERIDGE BMS925XC compare with peer Mini-Split Heat Pump units?
BLUERIDGE BMS925XC holds #957 of 2,096 (Top 47.6%, 42 tied) out of 2,096 verified mini-split heat pump models (+0.30 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 25.4 SEER2. Closest same-cohort alternatives include CanAir 4C25SCH09H11.
Where is BLUERIDGE BMS925XC compliant for 2026 US installation?
BLUERIDGE BMS925XC: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does BLUERIDGE BMS925XC model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, BLUERIDGE BMS925XC runs 354 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does BLUERIDGE BMS925XC cover?
BLUERIDGE BMS925XC covers 9,000-9,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does BLUERIDGE BMS925XC handle extreme weather or cold snaps?
Yes, BLUERIDGE BMS925XC carries ENERGY STAR Cold Climate certification (72.0% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern BLUERIDGE BMS925XC?
BLUERIDGE BMS925XC specifies R-454B compliance (PD ID 3712109); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in BLUERIDGE BMS925XC reach 25.4 SEER2?
Peak 25.4 SEER2 represents the top tested AHRI pairing for BLUERIDGE BMS925XC (PD ID 3712109); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to BLUERIDGE BMS925XC?
BLUERIDGE BMS925XC requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include CanAir 4C25SCH09H11.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.