AUX ASUM42HPMULO — Mini-Split Heat Pump Specifications
AUX ASUM42HPMULO (Mini-Split Heat Pump, PD ID 3417726) holds 1 ENERGY STAR certified SKU rated at 24.0 SEER2 — #1,599 of 2,096 (411 tied, beats 4.2% of peers), -1.10 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). AUX ASUM42HPMULO — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 24.0 SEER2 and Heating Rating set at 10.5 HSPF2.
- Max SEER2
- 24.0 SEER2
- Heating Rating
- 10.5 HSPF2
- Heating COP
- 2.0 COP
- Cohort Rank
- #1,599/2,096
- Verified Combos
- 1 SKU
- Sample PD ID
- 3417726
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | This series |
| 25.0 - 26.2 SEER2 | 785 | Peer range |
| 26.2 - 27.5 SEER2 | 272 | Peer range |
| 27.5 - 28.8 SEER2 | 150 | Peer range |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |
How does AUX ASUM42HPMULO rank across federal compliance and ENERGY STAR cohorts?
AUX ASUM42HPMULO ranks #1,599 of 2,096 (tied with 410 others at 24.0 SEER2, more efficient than 4.2% of certified series) for Max SEER2 (-1.10 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (81.0% capacity retention at 5F) (3.5 nominal Tons at 42,000 BTU/h) charged with R-32. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #1,599 of 2,096 (411 tied, beats 4.2% of peers) | -1.10 SEER2 vs 25.1 SEER2 category median |
| Heating HSPF2 vs Cohort | 10.5 HSPF2 | Equal to 10.5 HSPF2 median |
| Peak 95F EER2 vs Cohort | 12.5 EER2 | -1.50 EER2 vs 14.0 EER2 median |
| 5F Cold-Weather Capacity Retention | 81.0% of 47F rating | 5F COP 2.0 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 24.0 SEER2 / 10.5 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 12.5 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (1947/2096 series in category) |
| 2026 Cleaner Refrigerant Rule | R-454B / R-32 READY | Listed refrigerant: R-32; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does AUX ASUM42HPMULO require?
Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, AUX ASUM42HPMULO estimates reflect 1 certified SKU combination tested under PD ID 3417726.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 1,750 kWh/yr | $286/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 2,857 kWh/yr | $467/yr at US median |
| Combined Annual Electricity Cost | $752/yr | State range: $586 (NV) to $2,174 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 2,330 kWh/yr | $380/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to AUX ASUM42HPMULO?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for AUX ASUM42HPMULO (PD ID 3417726).
| ASUM42HPMULO | Matched AHRI Coil | 42,000 BTU/h | 24.0 SEER2 / 10.5 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on AUX ASUM42HPMULO, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across AUX ASUM42HPMULO: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for AUX ASUM42HPMULO exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- AUX ASUM42HPMULO uses A2L R-32, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal AUX ASUM42HPMULO fit | Single-family replacement needing documented ENERGY STAR PD ID 3417726 with matching indoor air handler. |
| Skip AUX ASUM42HPMULO if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable mini-split heat pump models deliver similar efficiency?
Compare AUX ASUM42HPMULO against ACIQ-42Z-E-HH-M5 and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does AUX ASUM42HPMULO compare with peer Mini-Split Heat Pump units?
AUX ASUM42HPMULO holds #1,599 of 2,096 (411 tied, beats 4.2% of peers) out of 2,096 verified mini-split heat pump models (-1.10 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 24.0 SEER2. Closest same-cohort alternatives include ACIQ-42Z-E-HH-M5.
Where is AUX ASUM42HPMULO compliant for 2026 US installation?
AUX ASUM42HPMULO: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does AUX ASUM42HPMULO model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, AUX ASUM42HPMULO runs 1,750 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does AUX ASUM42HPMULO cover?
AUX ASUM42HPMULO covers 42,000-42,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does AUX ASUM42HPMULO handle extreme weather or cold snaps?
Yes, AUX ASUM42HPMULO carries ENERGY STAR Cold Climate certification (81.0% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern AUX ASUM42HPMULO?
AUX ASUM42HPMULO specifies R-32 compliance (PD ID 3417726); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in AUX ASUM42HPMULO reach 24.0 SEER2?
Peak 24.0 SEER2 represents the top tested AHRI pairing for AUX ASUM42HPMULO (PD ID 3417726); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to AUX ASUM42HPMULO?
AUX ASUM42HPMULO requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include ACIQ-42Z-E-HH-M5.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)